Time-resolved x-ray solution scattering from detergent solubilized visual rhodopsin
Biophysical Journal · 2026
DOI: 10.1016/j.bpj.2026.01.014 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biophysical Journal, 2026. Verfasst von Daniel Sarabi und 14 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry and Molecular Biology, University of Gothenburg, Gothenburg, Sweden. Hauptthemen laut MEDLINE: Detergents, Rhodopsin, X-Ray Diffraction, Scattering, Radiation. Die Arbeit nennt 91 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Science Foundation, Horizon 2020 Framework Programme, Swedish Research Council.
Abstract (Originalsprache)
Time-resolved x-ray solution scattering (TR-XSS) studies provide experimental probes of transient conformational states in macromolecules. Difference x-ray scattering curves from integral membrane proteins are predicted to be influenced by the presence of the surrounding detergent micelle. Here, we present time-dependent x-ray solution scattering data from visual rhodopsin when solubilized in two different detergents: the nonionic surfactant n-dodecyl-β-D-maltoside and the zwitterionic detergent 3-[(3-cholamidopropyl) dimethylammonio]-1-propanesulfonate. Both detergents produce micelles that surround rhodopsin, yet they have different composition, density and critical micelle concentrations and yield different x-ray scattering properties. Our theoretical framework is able to fit the experimental TR-XSS data for photoactivated rhodopsin in both detergents, yielding experimental verification of how x-ray scattering contrast from the detergent molecules influences difference x-ray scattering measurements from integral membrane proteins. These results increase confidence when modeling conformational changes of integral membrane proteins from an ensemble of predicted structures.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Chemistry and Molecular Biology, University of Gothenburg, Gothenburg, Sweden.
- Department of Physics, University of Arizona, Tucson, Arizona.
- Division of Biology and Chemistry, Laboratory for Biomolecular Research, Paul Scherrer Institute, Villigen PSI, Switzerland.
- ESRF - The European Synchrotron, Grenoble, France.
- Department of Physics, University of Arizona, Tucson, Arizona; Department of Chemistry and Biochemistry, University of Arizona, Tucson, Arizona.
- Department of Chemistry and Molecular Biology, University of Gothenburg, Gothenburg, Sweden. Electronic address: richard.neutze@chem.gu.se.
Förderung
- National Science Foundation
- Horizon 2020 Framework Programme
- Swedish Research Council
- Swiss National Science Foundation
Zitieren
APA
Sarabi, D., Ostojić, L., Xu, X., Gruhl, T., Varma, N., Bosman, R., Berntsson, O., Pedersen, M. N., Sander, M., Wulff, M., Levantino, M., Schertler, G. F. X., Brown, M. F., Panneels, V., & Neutze, R. (2026). Time-resolved x-ray solution scattering from detergent solubilized visual rhodopsin. Biophysical Journal. https://doi.org/10.1016/j.bpj.2026.01.014
Vancouver
Sarabi D, Ostojić L, Xu X, Gruhl T, Varma N, Bosman R, et al. Time-resolved x-ray solution scattering from detergent solubilized visual rhodopsin. Biophysical Journal. 2026. doi:10.1016/j.bpj.2026.01.014
BibTeX
@article{Sarabi2026,
author = {Sarabi, Daniel and Ostojić, Lucija and Xu, Xiaolin and Gruhl, Thomas and Varma, Niranjan and Bosman, Robert and Berntsson, Oskar and Pedersen, Martin Nors and Sander, Mathias and Wulff, Michael and Levantino, Matteo and Schertler, Gebhard F X and Brown, Michael F and Panneels, Valerie and Neutze, Richard},
title = {Time-resolved x-ray solution scattering from detergent solubilized visual rhodopsin},
journal = {Biophysical Journal},
year = {2026},
doi = {10.1016/j.bpj.2026.01.014}
}
EUVIMED