Statistical analysis of the autocorrelation function in fluorescence correlation spectroscopy
Biophysical Journal · 2024
DOI: 10.1016/j.bpj.2024.01.011 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biophysical Journal, 2024. Verfasst von John Kohler und 2 weiteren Autor:innen. Beteiligte Einrichtung: School of Physics and Astronomy, University of Minnesota, Minneapolis, Minnesota. Hauptthemen laut MEDLINE: Spectrometry, Fluorescence. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIAID NIH HHS, NIGMS NIH HHS, University of Minnesota.
Abstract (Originalsprache)
Fluorescence correlation spectroscopy (FCS) is a powerful method to measure concentration, mobility, and stoichiometry in solution and in living cells, but quantitative analysis of FCS data remains challenging due to the correlated noise in the autocorrelation function (ACF) of FCS. We demonstrate here that least-squares fitting of the conventional ACF is incompatible with the χ2 goodness-of-fit test and systematically underestimates the true fit parameter uncertainty. To overcome this challenge, a simple method to fit the ACF is introduced that allows proper calculation of goodness-of-fit statistics and that provides more tightly constrained parameter estimates than the conventional least-squares fitting method, achieving the theoretical minimum uncertainty. Because this method requires significantly more data than the standard method, we further introduce an approximate method that requires fewer data. We demonstrate both these new methods using experiments and simulations of diffusion. Finally, we apply our method to FCS data of the peripheral membrane protein HRas, which has a slow-diffusing membrane-bound population and a fast-diffusing cytoplasmic population. Despite the order-of-magnitude difference of the diffusion times, conventional FCS fails to reliably resolve the two species, whereas the new method identifies the correct model and provides robust estimates of the fit parameters for both species.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- School of Physics and Astronomy, University of Minnesota, Minneapolis, Minnesota.
- School of Physics and Astronomy, University of Minnesota, Minneapolis, Minnesota; Institute for Molecular Virology, University of Minnesota, Minneapolis, Minnesota; Department of Biomedical Engineering, University of Mi…
Förderung
- NIAID NIH HHS
- NIGMS NIH HHS
- University of Minnesota
- Minnesota Supercomputing Institute, University of Minnesota
- National Institutes of Health
Zitieren
APA
Kohler, J., Hur, K. H., & Mueller, J. D. (2024). Statistical analysis of the autocorrelation function in fluorescence correlation spectroscopy. Biophysical Journal. https://doi.org/10.1016/j.bpj.2024.01.011
Vancouver
Kohler J, Hur KH, Mueller JD. Statistical analysis of the autocorrelation function in fluorescence correlation spectroscopy. Biophysical Journal. 2024. doi:10.1016/j.bpj.2024.01.011
BibTeX
@article{Kohler2024,
author = {Kohler, John and Hur, Kwang-Ho and Mueller, Joachim Dieter},
title = {Statistical analysis of the autocorrelation function in fluorescence correlation spectroscopy},
journal = {Biophysical Journal},
year = {2024},
doi = {10.1016/j.bpj.2024.01.011}
}
EUVIMED