EUVIMEDEUVIMED entdecken
Open Access

Statistical analysis of the autocorrelation function in fluorescence correlation spectroscopy

John Kohler, Kwang-Ho Hur, Joachim Dieter Mueller

Biophysical Journal · 2024

DOI: 10.1016/j.bpj.2024.01.011 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biophysical Journal, 2024. Verfasst von John Kohler und 2 weiteren Autor:innen. Beteiligte Einrichtung: School of Physics and Astronomy, University of Minnesota, Minneapolis, Minnesota. Hauptthemen laut MEDLINE: Spectrometry, Fluorescence. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIAID NIH HHS, NIGMS NIH HHS, University of Minnesota.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Fluorescence correlation spectroscopy (FCS) is a powerful method to measure concentration, mobility, and stoichiometry in solution and in living cells, but quantitative analysis of FCS data remains challenging due to the correlated noise in the autocorrelation function (ACF) of FCS. We demonstrate here that least-squares fitting of the conventional ACF is incompatible with the χ2 goodness-of-fit test and systematically underestimates the true fit parameter uncertainty. To overcome this challenge, a simple method to fit the ACF is introduced that allows proper calculation of goodness-of-fit statistics and that provides more tightly constrained parameter estimates than the conventional least-squares fitting method, achieving the theoretical minimum uncertainty. Because this method requires significantly more data than the standard method, we further introduce an approximate method that requires fewer data. We demonstrate both these new methods using experiments and simulations of diffusion. Finally, we apply our method to FCS data of the peripheral membrane protein HRas, which has a slow-diffusing membrane-bound population and a fast-diffusing cytoplasmic population. Despite the order-of-magnitude difference of the diffusion times, conventional FCS fails to reliably resolve the two species, whereas the new method identifies the correct model and provides robust estimates of the fit parameters for both species.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Spectrometry, FluorescenceDiffusionMembranes

Autor:innen und Institutionen

  • School of Physics and Astronomy, University of Minnesota, Minneapolis, Minnesota.
  • School of Physics and Astronomy, University of Minnesota, Minneapolis, Minnesota; Institute for Molecular Virology, University of Minnesota, Minneapolis, Minnesota; Department of Biomedical Engineering, University of Mi…

Förderung

  • NIAID NIH HHS
  • NIGMS NIH HHS
  • University of Minnesota
  • Minnesota Supercomputing Institute, University of Minnesota
  • National Institutes of Health

Zitieren

APA

Kohler, J., Hur, K. H., & Mueller, J. D. (2024). Statistical analysis of the autocorrelation function in fluorescence correlation spectroscopy. Biophysical Journal. https://doi.org/10.1016/j.bpj.2024.01.011

Vancouver

Kohler J, Hur KH, Mueller JD. Statistical analysis of the autocorrelation function in fluorescence correlation spectroscopy. Biophysical Journal. 2024. doi:10.1016/j.bpj.2024.01.011

BibTeX
@article{Kohler2024,
  author = {Kohler, John and Hur, Kwang-Ho and Mueller, Joachim Dieter},
  title = {Statistical analysis of the autocorrelation function in fluorescence correlation spectroscopy},
  journal = {Biophysical Journal},
  year = {2024},
  doi = {10.1016/j.bpj.2024.01.011}
}
Kostenlos starten →