From PCR to CRISPR: Comparing the detection performance of different nucleic acid detection technologies
Biomedical Instrumentation · 2025
DOI: 10.1016/j.bmi.2025.100026 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biomedical Instrumentation, 2025. Verfasst von Ruobo Peng und 5 weiteren Autor:innen. Die Arbeit nennt 53 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: National Natural Science Foundation of China, Shaanxi Province Key Research and Development Projects, National Key Research and Development Program of China.
Abstract (Originalsprache)
Real-time quantitative PCR (qPCR) is the gold standard for viral nucleic acid detection but requires specialized laboratories, trained personnel, and costly equipment, resulting in prolonged testing time. Isothermal amplification technologies (e.g., recombinase polymerase amplification (RPA)) have advanced rapidly, while CRISPR-based molecular diagnostics have gained widespread attention for their advantages in speed, specificity, and sensitivity. However, systematic investigations of different detection methods in practical applications remain limited. Especially for the same nucleic acid detection method, there are significant differences in detection time and detection limit in the existing literature, highlighting the urgent need to establish a unified standard to guide practical application. This study developed optimized RPA-assisted CRISPR nucleic acid detection systems (two-step and one-step methods) and systematically compared their performance with qPCR and RPA-fluorescence methods in viral nucleic acid detection. By systematically optimizing reagent concentrations and operational procedures, severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) RNA was used as the target to evaluate key metrics: detection time, sensitivity, and specificity. Results showed that qPCR had the highest sensitivity but required the longest detection time. The RPA-assisted CRISPR/Cas12a and Cas13a two-step method achieved a sensitivity of 1 copy/μL, demonstrating superior sensitivity and specificity within a 15-minute detection window compared to RPA-fluorescence assays. The RPA-assisted one-step method demonstrated good operational convenience with slightly reduced sensitivity and maintained specificity. • Developed optimized RPA-assisted CRISPR systems for rapid viral nucleic acid detection. • Achieved 1 cp/μL sensitivity in 15-min two-step CRISPR-Cas12a/Cas13a. • qPCR showed highest sensitivity but required longest detection time. • One-step CRISPR offered easy use with minor sensitivity loss.
Förderung
- National Natural Science Foundation of China
- Shaanxi Province Key Research and Development Projects
- National Key Research and Development Program of China
- State Key Laboratory for Manufacturing Systems Engineering
Zitieren
APA
Peng, R., Zhang, Y., Liu, J., Cui, S., Li, H., & Hu, F. (2025). From PCR to CRISPR: Comparing the detection performance of different nucleic acid detection technologies. Biomedical Instrumentation. https://doi.org/10.1016/j.bmi.2025.100026
Vancouver
Peng R, Zhang Y, Liu J, Cui S, Li H, Hu F. From PCR to CRISPR: Comparing the detection performance of different nucleic acid detection technologies. Biomedical Instrumentation. 2025. doi:10.1016/j.bmi.2025.100026
BibTeX
@article{Peng2025,
author = {Peng, Ruobo and Zhang, Yunyun and Liu, Jiangwei and Cui, Shuhui and Li, Huaizhong and Hu, Fei},
title = {From PCR to CRISPR: Comparing the detection performance of different nucleic acid detection technologies},
journal = {Biomedical Instrumentation},
year = {2025},
doi = {10.1016/j.bmi.2025.100026}
}
EUVIMED