Fachartikel in der Zeitschrift Bioorganic & Medicinal Chemistry, 2024-01. Verfasst von Vishakha Chaudhary und 7 weiteren Autor:innen. Beteiligte Einrichtung: Kirori Mal College, University of Delhi, North Campus, University Enclave, Delhi 110007, India; Department of Radiological Nuclear and Imaging Scienc…. Hauptthemen laut MEDLINE: Triple Negative Breast Neoplasms, Receptors, sigma. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 34 Literaturangaben. Gefördert von: Defence Research and Development Organisation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Over-expression of sigma-2 receptor in cancer cells provides an opportunity to develop molecular probes for diagnosis, even for non-receptor specific malignancies like triple negative breast cancers. In this work, a novel sigma-2 receptor ligand [THQ-DTPA] has been synthesized and characterized using 6,7-dimethoxy-1,2,3,4-tetrahydroisoquinoline (THQ) and diethylenetriaminepentaacetic acid (DTPA). The ligand is further chelated with 99mTc for application as metal based radiotracer [99mTc-THQ-DTPA]. Radiolabelling with 99mTc was achieved in an excellent yield of 98.0 ± 0.5% using stannous chloride as a reducing agent. The radioligand was found to be stable in human serum up-to 24 h, bio-compatible with less than 4% hemolysis, and exhibited high binding with sigma receptors isolated from rat liver membrane (Kd of 16.32 ± 4.93 nM and Bmax of 0.5232 ± 0.06 pmol/mg). Bio-distribution studies in triple-negative breast tumor bearing nude mice showed high tumor uptake after 30 min of injection with tumor/muscle (T/M) ratio of 3.58 ± 0.09. At 240 min, the T/M ratio (2.84 ± 0.20) decreased by 35% when administered in sigma blocked tumor bearing mice (1.81 ± 0.16) suggesting the selectivity of the ligand. Tumor imaging in gamma camera indicated a contrast of 3.56 at 30 min p.i. The above findings indicate that the ligand 99mTc-THQ-DTPA binds to sigma-2 receptors with high affinity and has potential for triple-negative breast tumor imaging.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Triple Negative Breast NeoplasmsReceptors, sigmaRatsMiceHumansAnimalsLigandsMice, NudePentetic AcidRadiopharmaceuticalsCell Line, TumorTomography, Emission-Computed, Single-Photon

Stichwörter der Autor:innen

6,7-dimethoxy-1,2,3,4-tetrahydroisoquinolineSPECT ImagingSigma-2 receptorTriple negative breast cancer (TNBC)Tumor imaging

Substanzen

sigma-2 receptorLigandsPentetic AcidReceptors, sigmaRadiopharmaceuticals

Autor:innen und Institutionen

  • Kirori Mal College, University of Delhi, North Campus, University Enclave, Delhi 110007, India; Department of Radiological Nuclear and Imaging Science, INMAS, DRDO, Timarpur, Delhi 110054, India.
  • Department of Radiological Nuclear and Imaging Science, INMAS, DRDO, Timarpur, Delhi 110054, India. Electronic address: Shubhra.inmas@gov.in.
  • University of California, San Francisco 94107, United States.
  • Department of Radiological Nuclear and Imaging Science, INMAS, DRDO, Timarpur, Delhi 110054, India; Dr. B.R. Ambedkar Center for Biomedical Research, University Enclave, Delhi 110007, India.
  • Department of Radiological Nuclear and Imaging Science, INMAS, DRDO, Timarpur, Delhi 110054, India; Centre for Nanotechnology, Indian Institute of Technology, Roorkee 247667, India.
  • Department of Radiological Nuclear and Imaging Science, INMAS, DRDO, Timarpur, Delhi 110054, India; Department of Chemistry, Banaras Hindu University, Varanasi 221005, India.

Förderung

  • Defence Research and Development Organisation

Zitieren

APA

Chaudhary, V., Chaturvedi, S., Wadhwa, A., Chaudhary, R., Gautam, D., Sharma, D., Kumar, R., & Mishra, A. K. (2024). Design, development and bio-evaluation of a novel radio-ligand 99mTc-THQ-DTPA as a sigma 2 receptor specific breast tumor imaging agent. Bioorganic & Medicinal Chemistry, 97, 117515. https://doi.org/10.1016/j.bmc.2023.117515

Vancouver

Chaudhary V, Chaturvedi S, Wadhwa A, Chaudhary R, Gautam D, Sharma D, et al. Design, development and bio-evaluation of a novel radio-ligand 99mTc-THQ-DTPA as a sigma 2 receptor specific breast tumor imaging agent. Bioorganic & Medicinal Chemistry. 2024;97:117515. doi:10.1016/j.bmc.2023.117515

BibTeX
@article{Chaudhary2024,
  author = {Chaudhary, Vishakha and Chaturvedi, Shubhra and Wadhwa, Anju and Chaudhary, Ritika and Gautam, Divya and Sharma, Deepika and Kumar, Rupesh and Mishra, A K},
  title = {Design, development and bio-evaluation of a novel radio-ligand 99mTc-THQ-DTPA as a sigma 2 receptor specific breast tumor imaging agent},
  journal = {Bioorganic & Medicinal Chemistry},
  year = {2024},
  volume = {97},
  pages = {117515},
  doi = {10.1016/j.bmc.2023.117515}
}
Kostenlos starten →