EUVIMEDEUVIMED entdecken
Crossref

Extended Reality-Assisted Preoperative Simulation for DIEP Flap Harvest Improves Interobserver Reliability of Perforator Identification

Hakuba Takeishi, Kazunori Watanabe, Ryo Shimoda, Yoshichika Yasunaga, Maki Sugimoto, Jun Araki

Journal of Plastic, Reconstructive & Aesthetic Surgery · 2026-10

DOI: 10.1016/j.bjps.2026.10.034 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Plastic, Reconstructive & Aesthetic Surgery, 2026-10. Verfasst von Hakuba Takeishi und 5 weiteren Autor:innen. Beteiligte Einrichtung: Division of Plastic and Reconstructive Surgery, Shizuoka Cancer Center Hospital, Shizuoka, Japan; Department of Plastic and Reconstructive Surgery, T…. Die Arbeit nennt 19 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Deep inferior epigastric perforator (DIEP) flap reconstruction requires precise understanding of the highly variable vascular anatomy. Although computed tomography angiography (CTA) facilitates preoperative planning, conventional two-dimensional (2D) images can be difficult to interpret, particularly for inexperienced surgeons. Extended reality (XR) enables immersive three-dimensional visualization; however, its impact on anatomical interpretation and interobserver reliability continues to be unclear. We evaluated whether XR improves DIEP flap assessment compared with 2D images. METHODS: Bilateral DIEPs from five patients (10 hemi-abdomens) who underwent preoperative CTA were analyzed. Four junior and three senior plastic surgeons evaluated perforator counts and DIEP-superficial inferior epigastric vein (DIEP-SIEV) linking vessels using either 2D images or XR visualization. Interobserver reliability was assessed using intraclass correlation coefficients (ICC) with 95% confidence intervals. Agreement between the junior and senior surgeons under each visualization modality was evaluated using the Bland-Altman analysis. In a separate analysis of the five hemi-abdomens from which the DIEP flaps were harvested, preoperative perforator counts were compared with the number of perforators that were identified and selected intraoperatively for flap harvest. RESULTS: On 2D images, junior surgeons identified significantly more perforators than seniors (89.0 ± 8.16 vs. 72.6 ± 3.05, P = 0.023), whereas no significant difference was observed in case of XR images (59.3 ± 2.5 vs. 56.0 ± 1.0). For DIEP-SIEV links, XR yielded significantly higher overall counts than 2D images (P = 0.04). Interobserver reliability was moderate for 2D images but improved with XR, particularly among the juniors. The Bland-Altman analysis demonstrated reduced variability and narrower agreement limits with XR, thereby indicating improved observer consistency. In the five hemi-abdomens used for DIEP flap harvest, the mean absolute error relative to the intraoperative reference was significantly lower with XR than with 2D imaging for all surgeons (0.86 ± 0.73 vs. 2.66 ± 1.75, P < 0.0001), and for junior (0.90 ± 0.79 vs. 3.50 ± 1.73, P < 0.0001) and senior surgeons (0.80 ± 0.68 vs. 1.53 ± 0.99, P = 0.022). CONCLUSIONS: XR visualization improved interobserver agreement and reduced experience-related variability in DIEP vascular assessment, with perforator counts aligning more closely with the intraoperative findings. XR may be a useful adjunct to preoperative planning and surgical education; however, further studies are needed to establish its impact on operative performance and patient outcomes.

Schlagwörter

Stichwörter der Autor:innen

Deep inferior epigastric perforator (DIEP)Extended reality (XR)Junior surgeonsSenior surgeonsSuperficial inferior epigastric vein (SIEV)Three-dimension (3D)

Autor:innen und Institutionen

  • Division of Plastic and Reconstructive Surgery, Shizuoka Cancer Center Hospital, Shizuoka, Japan; Department of Plastic and Reconstructive Surgery, The University of Tokyo, Tokyo, Japan.
  • Department of Diagnostic Radiology, Shizuoka Cancer Center Hospital, Shizuoka, Japan.
  • Medical Equipment and Machine Management Office, Shizuoka Cancer Center Hospital, Shizuoka, Japan.
  • Division of Plastic and Reconstructive Surgery, Shizuoka Cancer Center Hospital, Shizuoka, Japan.
  • Okinaga Research Institute, Teikyo University, Tokyo, Japan.
  • Division of Plastic and Reconstructive Surgery, Shizuoka Cancer Center Hospital, Shizuoka, Japan; Department of Plastic Surgery, Jichi Medical University, Tochigi, Japan. Electronic address: ja980079@yahoo.co.jp.

Zitieren

APA

Takeishi, H., Watanabe, K., Shimoda, R., Yasunaga, Y., Sugimoto, M., & Araki, J. (2026). Extended Reality-Assisted Preoperative Simulation for DIEP Flap Harvest Improves Interobserver Reliability of Perforator Identification. Journal of Plastic, Reconstructive & Aesthetic Surgery. https://doi.org/10.1016/j.bjps.2026.10.034

Vancouver

Takeishi H, Watanabe K, Shimoda R, Yasunaga Y, Sugimoto M, Araki J. Extended Reality-Assisted Preoperative Simulation for DIEP Flap Harvest Improves Interobserver Reliability of Perforator Identification. Journal of Plastic, Reconstructive & Aesthetic Surgery. 2026. doi:10.1016/j.bjps.2026.10.034

BibTeX
@article{Takeishi2026,
  author = {Takeishi, Hakuba and Watanabe, Kazunori and Shimoda, Ryo and Yasunaga, Yoshichika and Sugimoto, Maki and Araki, Jun},
  title = {Extended Reality-Assisted Preoperative Simulation for DIEP Flap Harvest Improves Interobserver Reliability of Perforator Identification},
  journal = {Journal of Plastic, Reconstructive & Aesthetic Surgery},
  year = {2026},
  doi = {10.1016/j.bjps.2026.10.034}
}
Kostenlos starten →