EUVIMEDEUVIMED entdecken
VergleichsstudieKohortenstudie

"Bio-Hammock" technique for prevention of expander inferior displacement in auricular reconstruction: A retrospective comparative cohort study of 198 patients

Jingwei Feng, Hongyu Zhang, Mengyuan Jiang, Jiajun Zhi, Leren He, Yanyong Zhao, Changchen Wang, Bingqing Wang, Meirong Yang

Journal of Plastic, Reconstructive & Aesthetic Surgery · 2026

DOI: 10.1016/j.bjps.2026.08.015 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of Plastic, Reconstructive & Aesthetic Surgery, 2026. Verfasst von Jingwei Feng und 8 weiteren Autor:innen. Beteiligte Einrichtung: Plastic Surgery Hospital and Institute, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China. Electronic address: 913…. Hauptthemen laut MEDLINE: Tissue Expansion Devices, Plastic Surgery Procedures, Tissue Expansion, Congenital Microtia. Die Arbeit nennt 13 Literaturangaben. Gefördert von: Innovation Fund, Chinese Academy of Medical Sciences.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Inferior displacement of tissue expanders during first-stage auricular reconstruction remains a persistent clinical challenge. We evaluated a modified dual-plane "bio-hammock" technique, in which the inferior pole of the expander (approximately 1.5-2.0 cm) is embedded within an intramuscular pocket fashioned within the sternocleidomastoid muscle (SCM) belly, because of its efficacy in preventing inferior displacement and reducing complications. METHODS: A retrospective cohort study was conducted on 198 patients with unilateral microtia who underwent first-stage expander implantation between January 2022 and December 2025. The modified dual-plane cohort (n=99) was treated using the modified dual-plane technique and conventional single-plane cohort (n=99) was treated using the conventional single-plane technique. All expanders (80 ml) were over-inflated to approximately 110 ml (137.5% of nominal volume). The primary outcome was inferior displacement distance prior to the second-stage procedure and secondary outcomes included complication rates, VAS pain scores, and patient satisfaction. RESULTS: Inferior displacement was significantly reduced in the modified dual-plane cohort compared with the conventional single-plane cohort [median 0.30 (IQR: 0.22-0.38) cm vs. 1.40 (IQR: 1.15-1.70) cm; P

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tissue Expansion DevicesPlastic Surgery ProceduresTissue ExpansionCongenital MicrotiaPostoperative ComplicationsHumansRetrospective StudiesMaleFemaleAdolescentChildAdultPatient SatisfactionTreatment OutcomeYoung AdultChild, Preschool

Stichwörter der Autor:innen

Auricular reconstructionBiomechanicsMicrotiaSternocleidomastoid muscleTissue expansion

Autor:innen und Institutionen

  • Plastic Surgery Hospital and Institute, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China. Electronic address: 913219477@qq.com.
  • Plastic Surgery Hospital and Institute, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China. Electronic address: 434442775@qq.com.
  • Plastic Surgery Hospital and Institute, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China. Electronic address: Jiangmengyuan9707@outlook.com.
  • Plastic Surgery Hospital and Institute, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China. Electronic address: zhijiajun627@vip.qq.com.
  • Plastic Surgery Hospital and Institute, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China. Electronic address: heleren@psh.pumc.edu.cn.
  • Plastic Surgery Hospital and Institute, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China. Electronic address: zhaoyanyong@psh.pumc.edu.cn.

Förderung

  • Innovation Fund
  • Chinese Academy of Medical Sciences

Zitieren

APA

Feng, J., Zhang, H., Jiang, M., Zhi, J., He, L., Zhao, Y., Wang, C., Wang, B., & Yang, M. (2026). "Bio-Hammock" technique for prevention of expander inferior displacement in auricular reconstruction: A retrospective comparative cohort study of 198 patients. Journal of Plastic, Reconstructive & Aesthetic Surgery. https://doi.org/10.1016/j.bjps.2026.08.015

Vancouver

Feng J, Zhang H, Jiang M, Zhi J, He L, Zhao Y, et al. "Bio-Hammock" technique for prevention of expander inferior displacement in auricular reconstruction: A retrospective comparative cohort study of 198 patients. Journal of Plastic, Reconstructive & Aesthetic Surgery. 2026. doi:10.1016/j.bjps.2026.08.015

BibTeX
@article{Feng2026,
  author = {Feng, Jingwei and Zhang, Hongyu and Jiang, Mengyuan and Zhi, Jiajun and He, Leren and Zhao, Yanyong and Wang, Changchen and Wang, Bingqing and Yang, Meirong},
  title = {"Bio-Hammock" technique for prevention of expander inferior displacement in auricular reconstruction: A retrospective comparative cohort study of 198 patients},
  journal = {Journal of Plastic, Reconstructive & Aesthetic Surgery},
  year = {2026},
  doi = {10.1016/j.bjps.2026.08.015}
}
Kostenlos starten →