Portable 3D scanning for upper and lower limb lymphedema: Posture optimization and clinical agreement with the circumferential method
Journal of Plastic, Reconstructive & Aesthetic Surgery · 2026
DOI: 10.1016/j.bjps.2026.07.034 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Journal of Plastic, Reconstructive & Aesthetic Surgery, 2026. Verfasst von Yue Chen und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgery, Faculty of Medicine, Complutense University of Madrid, Madrid, Spain; Department of Plastic and Reconstructive Surgery, Hospit…. Hauptthemen laut MEDLINE: Lymphedema, Imaging, Three-Dimensional, Lower Extremity, Upper Extremity. Die Arbeit nennt 33 Literaturangaben.
Abstract (Originalsprache)
OBJECTIVE: To evaluate the agreement between portable 3D scanning and routine circumferential assessment for limb volume measurement in upper- and lower-limb lymphedema, and to provide a reusable posture-scanning standard operating procedure (SOP) and rapid circumferential volume calculator to facilitate standardized use in routine practice. METHODS: This single-center prospective cross-sectional method-comparison study of 20 patients included 10 patients with upper-limb and 10 patients with lower-limb lymphedema undergoing same-visit limb volumetry via circumferential tape and portable 3D scanning (Revopoint Miraco Plus®). Percent excess volume (Δ-3D%, Δ-circ%) was computed for each method, and agreement was assessed using the Bland-Altman analysis of the difference (Δ-3D% - Δ-circ%, percentage points), plus correlation and linear regression. The clinic SOP specified seated upper-limb scanning with the arm raised, standing lower-limb scanning with chest up and legs apart, a 360° helical sweep with 10-15% overlap, real-time quality control (mesh defect
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Surgery, Faculty of Medicine, Complutense University of Madrid, Madrid, Spain; Department of Plastic and Reconstructive Surgery, Hospital General Universitario Gregorio Marañón, Madrid, Spain.
- Department of Plastic and Reconstructive Surgery, Hospital General Universitario Gregorio Marañón, Madrid, Spain.
- Department of Plastic Surgery, Hospital de la Santa Creu i Sant Pau, Universitat Autònoma de Barcelona, Barcelona, Spain.
- Department of Surgery, Faculty of Medicine, Complutense University of Madrid, Madrid, Spain; Department of Plastic and Reconstructive Surgery, Hospital General Universitario Gregorio Marañón, Madrid, Spain. Electronic a…
Zitieren
APA
Chen, Y., Sánchez, Á. G., Xu, Y., Masià, J., & Lasso, J. M. (2026). Portable 3D scanning for upper and lower limb lymphedema: Posture optimization and clinical agreement with the circumferential method. Journal of Plastic, Reconstructive & Aesthetic Surgery. https://doi.org/10.1016/j.bjps.2026.07.034
Vancouver
Chen Y, Sánchez ÁG, Xu Y, Masià J, Lasso JM. Portable 3D scanning for upper and lower limb lymphedema: Posture optimization and clinical agreement with the circumferential method. Journal of Plastic, Reconstructive & Aesthetic Surgery. 2026. doi:10.1016/j.bjps.2026.07.034
BibTeX
@article{Chen2026,
author = {Chen, Yue and Sánchez, Álvaro García-Cañal and Xu, Yingyue and Masià, Jaume and Lasso, José M},
title = {Portable 3D scanning for upper and lower limb lymphedema: Posture optimization and clinical agreement with the circumferential method},
journal = {Journal of Plastic, Reconstructive & Aesthetic Surgery},
year = {2026},
doi = {10.1016/j.bjps.2026.07.034}
}
EUVIMED