EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Development of a software-assisted workflow for transforming CTA-derived perforator information into standardized surgical planning coordinates

Sergi Barrantes, Pau Lapeña, Peng Qi, Antonio J Sánchez Egea

Journal of Plastic, Reconstructive & Aesthetic Surgery · 2026

DOI: 10.1016/j.bjps.2026.07.009 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Plastic, Reconstructive & Aesthetic Surgery, 2026. Verfasst von Sergi Barrantes und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Plastic & Reconstructive Surgery, Bellvitge University Hospital, Barcelona, Spain. Hauptthemen laut MEDLINE: Computed Tomography Angiography, Perforator Flap, Mammaplasty, Software. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Government of Catalonia Agency for Administration of University and Research Grants.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Precise anatomical mapping of the deep inferior epigastric perforator (DIEP) flap is essential for successful breast reconstruction. Although computed tomography angiography (CTA) is the gold standard for preoperative planning, manual identification of perforators is time-consuming and subject to inter-rater variability. We aimed to validate a self-developed image-processing tool designed to standardize coordinate extraction and automate two-dimensional spatial mapping of pre-selected abdominal wall perforators. METHODS: A retrospective analysis was conducted on 52 patients who underwent DIEP flap reconstruction between 2017 and 2021. A total of 170 perforators were analyzed. The custom software processed axial CTA slices through histogram analysis and frequency-range filtering (1800-2200 HU) to enhance vascular visualization. Cartesian coordinates of clinician-selected perforators were calculated relative to the navel base (0, 0) and compared with manual radiological assessments to validate spatial fidelity. RESULTS: Analysis of 170 cutaneous perforators (n=52) showed predominant concentration in the lower abdominal quadrants. Centroids were (1.4, -20.2) mm for radiological assessment and (1.8, -21.2) mm for our software, relative to the umbilicus. Validation demonstrated high concordance, with a minimal systematic bias of (-0.4, 1.0) mm and a root mean square error of 6.04 mm, within clinically acceptable margins. Standardized mapping and visual report generation averaged 8 ± 6 min per patient, thereby providing a rapid turnaround for converting coordinate data into a standardized surgical guide. CONCLUSIONS: The validated tool provides a reliable, objective framework for standardizing and visualizing existing radiological data in DIEP flap planning. Although it does not alter clinical perforator selection or advance surgical technique, this technical utility provides an autonomous data-processing pathway to generate standardized spatial roadmaps, thereby optimizing the preoperative imaging workflow and safeguarding administrative timelines against potential interdepartmental reporting bottlenecks.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Computed Tomography AngiographyPerforator FlapMammaplastySoftwareWorkflowEpigastric ArteriesAbdominal WallHumansRetrospective StudiesFemaleMiddle AgedImage Processing, Computer-Assisted

Stichwörter der Autor:innen

Breast reconstructionComputed tomography angiographyDIEP flapImage processingPerforator mappingSurgical planning

Autor:innen und Institutionen

  • Department of Plastic & Reconstructive Surgery, Bellvitge University Hospital, Barcelona, Spain.
  • Department of Control Science and Engineering, Tongji University, Shanghai, China.
  • Department of Mechanical Engineering, Universitat Politècnica de Catalunya, Barcelona, Spain. Electronic address: antonio.egea@upc.edu.

Förderung

  • Government of Catalonia Agency for Administration of University and Research Grants

Zitieren

APA

Barrantes, S., Lapeña, P., Qi, P., & Egea, A. J. S. (2026). Development of a software-assisted workflow for transforming CTA-derived perforator information into standardized surgical planning coordinates. Journal of Plastic, Reconstructive & Aesthetic Surgery. https://doi.org/10.1016/j.bjps.2026.07.009

Vancouver

Barrantes S, Lapeña P, Qi P, Egea AJS. Development of a software-assisted workflow for transforming CTA-derived perforator information into standardized surgical planning coordinates. Journal of Plastic, Reconstructive & Aesthetic Surgery. 2026. doi:10.1016/j.bjps.2026.07.009

BibTeX
@article{Barrantes2026,
  author = {Barrantes, Sergi and Lapeña, Pau and Qi, Peng and Egea, Antonio J Sánchez},
  title = {Development of a software-assisted workflow for transforming CTA-derived perforator information into standardized surgical planning coordinates},
  journal = {Journal of Plastic, Reconstructive & Aesthetic Surgery},
  year = {2026},
  doi = {10.1016/j.bjps.2026.07.009}
}