External vacuum expansion in autologous fat transfer as total breast reconstruction: Is it worth it? The interim analysis of the multicentre randomised controlled EVE trial
Journal of Plastic, Reconstructive & Aesthetic Surgery · 2026-08 · 119 · 85-96
DOI: 10.1016/j.bjps.2026.05.072 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift Journal of Plastic, Reconstructive & Aesthetic Surgery, 2026-08. Verfasst von Wessel B W van der Venne und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Plastic, Reconstructive, and Hand Surgery, Maastricht University Medical Centre+, P.O. box 5800, 6202 AZ Maastricht, the Netherlands; N…. Hauptthemen laut MEDLINE: Mammaplasty, Adipose Tissue, Tissue Expansion. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: ZonMw.
Abstract (Originalsprache)
BACKGROUND: Autologous fat transfer (AFT) is an emerging option for total breast reconstruction. To improve graft survival, perioperative external vacuum expansion (EVE) is used to optimise recipient-site environment. However, the efficacy of EVE and its treatment burden on women needs consideration. This interim analysis of a multicentre randomised controlled trial (RCT) evaluates the effect of EVE on volumetric outcomes and safety. METHODS: Women undergoing total breast reconstruction with AFT were randomised 2:1 to perioperative EVE or no EVE. All participants underwent three AFT sessions followed by magnetic resonance imaging (MRI)-based volumetric assessment at six months. Primary outcomes were percentage augmentation and graft retention. Secondary outcomes included (serious) adverse events (SAEs). Quality-of-life (QoL) outcomes were not analysed in this interim analysis, as reconstruction was ongoing. RESULTS: Fifty-three participants were included (EVE, N = 32; control, N = 21). Mean augmentation was 190.7% with EVE versus 176.4% without (adjusted difference 14.6%; 95% CI -80.0 to 109.1; p = 0.757). Graft retention was 39.3% and 34.9%, respectively (difference 4.5%; 95% CI -6.4 to 15.4; p = 0.405). Both outcomes showed no statistically significant between-group differences. The EVE group experienced more AEs (22 AEs and 5 SAEs) compared with the control group (three AEs and two SAEs), which were predominantly skin-related complications. CONCLUSIONS: Perioperative EVE use did not yield significant improvements in augmentation or graft retention; however, it was associated with higher treatment burden and more (S)AEs. Final analyses of our ongoing RCT, incorporating patient-reported QoL outcomes are still awaited. Based on this interim analysis, the clinical benefit of EVE in reconstructive settings remains uncertain and warrants additional research.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Plastic, Reconstructive, and Hand Surgery, Maastricht University Medical Centre+, P.O. box 5800, 6202 AZ Maastricht, the Netherlands; NUTRIM School for Nutrition, and Translational Research in Metabolism,…
- Department of Plastic, Reconstructive, and Hand Surgery, Maastricht University Medical Centre+, P.O. box 5800, 6202 AZ Maastricht, the Netherlands; GROW School for Oncology and Reproduction, Maastricht University, P.O.…
- Department of Clinical Epidemiology and Medical Technology Assessment (KEMTA), Maastricht University Medical Centre+, 6229 HX Maastricht, the Netherlands.
- NUTRIM School for Nutrition, and Translational Research in Metabolism, Maastricht University, P.O. Box 616, Universiteitssingel 40, 6229 ER Maastricht, the Netherlands.
- Faculty of Health, Medicine and Life Sciences, Maastricht University, Universiteitssingel 40, 6229 ER Maastricht, the Netherlands.
- Department of Radiology and Nuclear Medicine, Maastricht University Medical Centre+, P.O. Box 5800, 6202 AZ Maastricht, the Netherlands.
Förderung
- ZonMw
Zitieren
APA
van der Venne, W. B. W., Smeins, N. N. P. M., Kuijlaars, Z. M. A., Van Kuijk, S. M. J., Rijkx, M. E. P., Bernardi, E., Houwers, J. B., Heuts, E. M., EVE trial investigators, Van der Hulst, R. R. W. J., & Piatkowski, A. (2026). External vacuum expansion in autologous fat transfer as total breast reconstruction: Is it worth it? The interim analysis of the multicentre randomised controlled EVE trial. Journal of Plastic, Reconstructive & Aesthetic Surgery, 119, 85-96. https://doi.org/10.1016/j.bjps.2026.05.072
Vancouver
van der Venne WBW, Smeins NNPM, Kuijlaars ZMA, Van Kuijk SMJ, Rijkx MEP, Bernardi E, et al. External vacuum expansion in autologous fat transfer as total breast reconstruction: Is it worth it? The interim analysis of the multicentre randomised controlled EVE trial. Journal of Plastic, Reconstructive & Aesthetic Surgery. 2026;119:85-96. doi:10.1016/j.bjps.2026.05.072
BibTeX
@article{vanderVenne2026,
author = {van der Venne, Wessel B W and Smeins, Nieke N P M and Kuijlaars, Zoë M A and Van Kuijk, Sander M J and Rijkx, Maud E P and Bernardi, Ella and Houwers, Janneke B and Heuts, Esther M and EVE trial investigators, EVE trial investigators and Van der Hulst, René R W J and Piatkowski, A},
title = {External vacuum expansion in autologous fat transfer as total breast reconstruction: Is it worth it? The interim analysis of the multicentre randomised controlled EVE trial},
journal = {Journal of Plastic, Reconstructive & Aesthetic Surgery},
year = {2026},
volume = {119},
pages = {85--96},
doi = {10.1016/j.bjps.2026.05.072}
}
EUVIMED