Hydrofluoric acid inhalation injury after electric bike battery fire
Journal of Plastic, Reconstructive & Aesthetic Surgery · 2026-07 · 118 · 424-427
DOI: 10.1016/j.bjps.2026.04.035 ↗Kurz gefasst
Fallbericht in der Zeitschrift Journal of Plastic, Reconstructive & Aesthetic Surgery, 2026-07. Verfasst von Stephen Keelan und 4 weiteren Autor:innen. Beteiligte Einrichtung: National Burns Unit, Department of Plastic & Reconstructive Surgery, St. James's Hospital, St. James's Street, Dublin 8, Ireland. Electronic address:…. Hauptthemen laut MEDLINE: Bicycling, Burns, Chemical, Burns, Inhalation, Electric Power Supplies. Die Arbeit nennt 3 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: The rapid increase in electric bike (e-bike) use has led to a rise in lithium-ion battery fires, which present significant hazards. Beyond thermal injury, these fires emit toxic gases such as hydrogen fluoride (HF), capable of causing severe chemical inhalation injury. The pulmonary effects of inhaled hydrofluoric acid are not well characterised in the literature. CASES: Two cases of severe lung injury occurred following indoor e-bike battery fires. The first patient sustained 32% total body surface area (TBSA) burns and developed acute respiratory distress syndrome with radiological evidence of chemical pneumonitis, necessitating prolonged mechanical ventilation and resulting in persistent pulmonary impairment. The second patient sustained 44% TBSA burns and experienced rapidly progressive respiratory failure that was disproportionate to typical smoke inhalation injury. Despite maximal supportive therapy, including extracorporeal membrane oxygenation, the patient died from catastrophic pulmonary failure. CONCLUSION: Lithium-ion battery fires present both thermal and chemical hazards, especially in enclosed environments. These cases highlight the importance of maintaining a high index of suspicion for toxic inhalation injury, promptly recognising disproportionate respiratory failure, and monitoring for biochemical indicators of hydrofluoric acid exposure as the prevalence of lithium-ion battery use increases.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- National Burns Unit, Department of Plastic & Reconstructive Surgery, St. James's Hospital, St. James's Street, Dublin 8, Ireland. Electronic address: stephenkeelan@rcsi.com.
- National Burns Unit, Department of Plastic & Reconstructive Surgery, St. James's Hospital, St. James's Street, Dublin 8, Ireland.
- National Burns Unit, Department of Anaesthetics, St. James's Hospital, St. James's Street, Dublin 8, Ireland.
Zitieren
APA
Keelan, S., Murphy, M., Abrahams, M., Shelley, O., & Kennedy, S. (2026). Hydrofluoric acid inhalation injury after electric bike battery fire. Journal of Plastic, Reconstructive & Aesthetic Surgery, 118, 424-427. https://doi.org/10.1016/j.bjps.2026.04.035
Vancouver
Keelan S, Murphy M, Abrahams M, Shelley O, Kennedy S. Hydrofluoric acid inhalation injury after electric bike battery fire. Journal of Plastic, Reconstructive & Aesthetic Surgery. 2026;118:424-427. doi:10.1016/j.bjps.2026.04.035
BibTeX
@article{Keelan2026,
author = {Keelan, Stephen and Murphy, Maria and Abrahams, Mark and Shelley, Odhran and Kennedy, Sharon},
title = {Hydrofluoric acid inhalation injury after electric bike battery fire},