EUVIMEDEUVIMED entdecken
Crossref

Early detection of viable microorganisms in “sterile” periprosthetic fluids in implant-based breast reconstruction: A bioelectrochemical approach using screen-printed electrodes

Marta Monari, Stefano Vaccari, Alessandro Marco Lupacchini, Anna Parisi, Nicki Zolesi, Sara Beltrame, Paola Petrillo, Fabio Grizzi, Mohamed Ahmed Ahmed Abdelaziz Hegazi, Riccardo Di Giuli, Francesco Klinger, Roberto Rusconi und 1 weitere

Journal of Plastic, Reconstructive & Aesthetic Surgery · 2026

DOI: 10.1016/j.bjps.2025.11.045 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Plastic, Reconstructive & Aesthetic Surgery, 2026. Verfasst von Marta Monari und 12 weiteren Autor:innen. Beteiligte Einrichtung: Laboratory of Clinical Analysis, Humanitas Mater Domini, Castellanza, Varese, Italy. Hauptthemen laut MEDLINE: Prosthesis-Related Infections, Dielectric Spectroscopy, Breast Implants, Breast Implantation. Die Arbeit nennt 20 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Early postoperative infections are an important complication after postmastectomy implant-based breast reconstruction with current diagnostic methods requiring long processing times and potentially yielding false negatives, particularly after prior antibiotic exposure. We aimed to evaluate the feasibility and diagnostic accuracy of a bioelectrochemical method, based on electrochemical impedance spectroscopy (EIS), for the early detection of viable bacteria in periprosthetic fluid following implant-based reconstruction. METHODS: A total of 47 patients undergoing immediate implant-based breast reconstruction were prospectively enrolled. Periprosthetic fluid samples were collected from the drainage tube at postoperative days 7 and/or 14 (107 samples in total). Each sample was analyzed using 3 diagnostic platforms: (1) EIS, (2) molecular diagnostics, and (3) conventional microbiology. The EIS signal (Z') was interpreted against a cut-off calibrated using gram-positive and gram-negative reference suspensions. RESULTS: Infection was confirmed in 8 out of 47 patients (17.0%). EIS correctly identified all infected cases, showing full concordance with culture and molecular results. The technique distinguished gram-positive (Z' 6000-20,000 Ohms) from gram-negative infections (Z' 21,000-35,000 Ohms). The analytical time for EIS was approximately 9 min. Among positive patients, gram-positive infections were mostly asymptomatic or mild, whereas gram-negative infections were associated with severe clinical outcomes, including explantation. CONCLUSION: EIS offers a rapid, low-cost, and easy-to-use method for detecting bacterial presence in periprosthetic fluids. Unlike standard microbiological or molecular tests, it does not require bacterial growth, sample preparation, or nucleic acid extraction. With further validation, it has strong potential to support earlier, more tailored interventions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Prosthesis-Related InfectionsDielectric SpectroscopyBreast ImplantsBreast ImplantationHumansFemaleMiddle AgedProspective StudiesAdultElectrodesEarly DiagnosisAgedFeasibility Studies

Stichwörter der Autor:innen

Breast cancerBreast implantElectrochemical impedance spectroscopyImplant-based breast reconstructionInfection diagnosisReconstructive surgery

Autor:innen und Institutionen

  • Laboratory of Clinical Analysis, Humanitas Mater Domini, Castellanza, Varese, Italy.
  • Department of Medical Biotechnology and Translational Medicine BIOMETRA, Plastic Reconstructive and Aesthetic Plastic Surgery School, Università degli Studi Di Milano, via Festa del Perdono 7, 20122 Milan, Italy; Depart…
  • Department of Medical Biotechnology and Translational Medicine BIOMETRA, Plastic Reconstructive and Aesthetic Plastic Surgery School, Università degli Studi Di Milano, via Festa del Perdono 7, 20122 Milan, Italy.
  • Department of Biomedical Sciences, Humanitas University, Via Rita Levi Montalcini 4, Pieve Emanuele, 20090 Milan, Italy.
  • Department of Biomedical Sciences, Humanitas University, Milan, Italy; Department of Immunology and Inflammation, IRCCS Humanitas Research Hospital, Rozzano, Milan, Italy.
  • Department of Immunology and Inflammation, IRCCS Humanitas Research Hospital, Rozzano, Milan, Italy.

Zitieren

APA

Monari, M., Vaccari, S., Lupacchini, A. M., Parisi, A., Zolesi, N., Beltrame, S., Petrillo, P., Grizzi, F., Hegazi, M. A. A. A., Giuli, R. D., Klinger, F., Rusconi, R., & Vinci, V. (2026). Early detection of viable microorganisms in “sterile” periprosthetic fluids in implant-based breast reconstruction: A bioelectrochemical approach using screen-printed electrodes. Journal of Plastic, Reconstructive & Aesthetic Surgery. https://doi.org/10.1016/j.bjps.2025.11.045

Vancouver

Monari M, Vaccari S, Lupacchini AM, Parisi A, Zolesi N, Beltrame S, et al. Early detection of viable microorganisms in “sterile” periprosthetic fluids in implant-based breast reconstruction: A bioelectrochemical approach using screen-printed electrodes. Journal of Plastic, Reconstructive & Aesthetic Surgery. 2026. doi:10.1016/j.bjps.2025.11.045

BibTeX
@article{Monari2026,
  author = {Monari, Marta and Vaccari, Stefano and Lupacchini, Alessandro Marco and Parisi, Anna and Zolesi, Nicki and Beltrame, Sara and Petrillo, Paola and Grizzi, Fabio and Hegazi, Mohamed Ahmed Ahmed Abdelaziz and Giuli, Riccardo Di and Klinger, Francesco and Rusconi, Roberto and Vinci, Valeriano},
  title = {Early detection of viable microorganisms in “sterile” periprosthetic fluids in implant-based breast reconstruction: A bioelectrochemical approach using screen-printed electrodes},
  journal = {Journal of Plastic, Reconstructive & Aesthetic Surgery},
  year = {2026},
  doi = {10.1016/j.bjps.2025.11.045}
}
Kostenlos starten →