Examination of the masseter muscle in patients with hemifacial microsomia using high-frequency ultrasound and shear wave elastography
Journal of Plastic, Reconstructive & Aesthetic Surgery · 2024
DOI: 10.1016/j.bjps.2024.07.009 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Plastic, Reconstructive & Aesthetic Surgery, 2024. Verfasst von Ying Jia und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ultrasound, Plastic Surgery Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100144, China. Hauptthemen laut MEDLINE: Masseter Muscle, Elasticity Imaging Techniques. Die Arbeit nennt 30 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: This study aimed to prospectively investigate the reference values for masseter muscle thickness and hardness using ultrasonography and shear wave elastography, respectively, in patients with hemifacial microsomia (HFM). METHODS: We enrolled 51 patients, aged 5-20 years, with HFM including 31 males and 20 females. The upper-lower, left-right, and anterior-posterior diameters of 102 masseter muscles and stiffness of 98 masseter muscles were determined by examining the unaffected and affected sides of each participant's face. RESULTS: The upper-lower, left-right, and anterior-posterior diameters of the masseter muscle were significantly smaller at rest (4.26 ± 0.83, 2.94 ± 0.75, and- 0.80 ± 0.25 cm, respectively) and during contraction (3.95 ± 0.78, 2.71 ± 0.78, and 0.87 ± 0.29 cm, respectively) in the affected side than those in the healthy side (5.45 ± 0.66, 3.87 ± 0.49, and 0.97 ± 0.20 cm, respectively, at rest and 4.99 ± 0.45, 3.49 ± 0.53, and 1.07 ± 0.23 cm, respectively, during contraction, p < 0.05). In the resting state, the hardness of the masseter muscle on the affected side (0.77 ± 0.66 m/s) was significantly greater than that on the healthy side (0.42 ± 0.41 m/s; p < 0.05). The magnitude of changes in the upper-lower, left-right, and anterior-posterior diameters of the biting muscle in the occlusal state were significantly smaller on the affected side (-0.30 ± 0.27, -0.23 ± 0.17, and 0.08 ± 0.08 cm, respectively) than those in the healthy side (-0.47 ± 0.38, -0.37 ± 0.25, and 0.10 ± 0.12 cm, respectively, p < 0.05). CONCLUSIONS: The knowledge of these values allows for better understanding of the disease characteristics of HFM, which may be used for its diagnosis, treatment, and prognosis. Patients experiencing different severity levels exhibited significant differences in the morphology and function of the masseter muscle on the affected-side (p < 0.05). EVIDENCE LEVEL: Level III.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Ultrasound, Plastic Surgery Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100144, China.
- Department of Ear Reconstruction, Plastic Surgery Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100144, China.
- Xi'an Jiaotong University, Xi'an, Shaanxi 710061, China.
- Department of Cosmetic Injection Center, Plastic Surgery Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100144, China.
- Department of Ultrasound, Plastic Surgery Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100144, China. Electronic address: 373350225@qq.com.
Zitieren
APA
Jia, Y., Zhang, Z., Tawulan, T., Wang, Y., Chen, Y., Chai, H., & Hu, J. (2024). Examination of the masseter muscle in patients with hemifacial microsomia using high-frequency ultrasound and shear wave elastography. Journal of Plastic, Reconstructive & Aesthetic Surgery. https://doi.org/10.1016/j.bjps.2024.07.009
Vancouver
Jia Y, Zhang Z, Tawulan T, Wang Y, Chen Y, Chai H, et al. Examination of the masseter muscle in patients with hemifacial microsomia using high-frequency ultrasound and shear wave elastography. Journal of Plastic, Reconstructive & Aesthetic Surgery. 2024. doi:10.1016/j.bjps.2024.07.009
BibTeX
@article{Jia2024,
author = {Jia, Ying and Zhang, Ziming and Tawulan, Tulepaer and Wang, Yuhao and Chen, Yi and Chai, Hongli and Hu, Jintian},
title = {Examination of the masseter muscle in patients with hemifacial microsomia using high-frequency ultrasound and shear wave elastography},
journal = {Journal of Plastic, Reconstructive & Aesthetic Surgery},
year = {2024},
doi = {10.1016/j.bjps.2024.07.009}
}
EUVIMED