EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Establishing test-retest reliability and the smallest detectable change of FACE-Q Aesthetic Module scales

Lucas Gallo, Charlene Rae, Patrick J Kim, Sophocles H Voineskos, Achilles Thoma, Andrea L Pusic, Anne F Klassen, Stefan J Cano

Journal of Plastic, Reconstructive & Aesthetic Surgery · 2024

DOI: 10.1016/j.bjps.2024.06.002 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Plastic, Reconstructive & Aesthetic Surgery, 2024. Verfasst von Lucas Gallo und 7 weiteren Autor:innen. Beteiligte Einrichtung: Division of Plastic Surgery, McMaster University, Hamilton, ON, Canada. Electronic address: lucas.gallo@medportal.ca. Hauptthemen laut MEDLINE: Esthetics, Face. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: The test-retest (TRT) reliability of FACE-Q Aesthetic scales is yet to be assessed. The aim of this study was to establish the TRT reliability of 17 FACE-Q Aesthetic scales and determine the smallest detectable change (SDC) that can be identified using these scales. METHODS: Data were collected from an online international sample platform (Prolific). Participants ≥20 years old, who had been to a dermatologist or plastic surgeon for a facial aesthetic treatment within the past 12 months were asked to provide demographic and clinical information and complete an online REDcap survey consisting of 17 FACE-Q Aesthetic scales. Participants were asked if they would be willing to complete the survey again in 7 days. Only the participants who reported no important change in the scale construct and completed the retest within 14 days were included. RESULTS: A total of 342 unique participants completed the TRT survey. The mean age of the sample was 36.6 (±11.5) years, and 82.4% were female. With outlier data removed, all FACE-Q scales demonstrated an intraclass correlation coefficient >0.70 indicating "good" TRT reliability. The standard error of measurement for the included scales ranged from 3.37 to 11.87, corresponding to a range of SDCgroup from 0.95 to 3.23 and SDCind from 9.34 to 32.91. CONCLUSION: All included FACE-Q scales demonstrated sufficient TRT reliability and stability overall after the outlier data were removed. Moreover, the authors calculated the values for the SDC for these scales.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

EstheticsFaceHumansFemaleMaleReproducibility of ResultsAdultSurveys and QuestionnairesMiddle AgedPatient SatisfactionYoung Adult

Stichwörter der Autor:innen

AestheticCosmeticFACE-QPatient-reported outcome measuresQuality of lifeReliability

Autor:innen und Institutionen

  • Division of Plastic Surgery, McMaster University, Hamilton, ON, Canada. Electronic address: lucas.gallo@medportal.ca.
  • Department of Pediatrics, McMaster University, Hamilton, ON, Canada.
  • Division of Plastic Surgery, McMaster University, Hamilton, ON, Canada.
  • Division of Plastic and Reconstructive Surgery, University of Toronto, Toronto, ON, Canada.
  • Department of Health Research Methods, Evidence & Impact, McMaster University, Hamilton, ON, Canada; Department of Surgery, Division of Plastic Surgery, McMaster University, Hamilton, ON, Canada.
  • Division of Plastic Surgery, Brigham and Women's Hospital, Boston, MA, USA.

Zitieren

APA

Gallo, L., Rae, C., Kim, P. J., Voineskos, S. H., Thoma, A., Pusic, A. L., Klassen, A. F., & Cano, S. J. (2024). Establishing test-retest reliability and the smallest detectable change of FACE-Q Aesthetic Module scales. Journal of Plastic, Reconstructive & Aesthetic Surgery. https://doi.org/10.1016/j.bjps.2024.06.002

Vancouver

Gallo L, Rae C, Kim PJ, Voineskos SH, Thoma A, Pusic AL, et al. Establishing test-retest reliability and the smallest detectable change of FACE-Q Aesthetic Module scales. Journal of Plastic, Reconstructive & Aesthetic Surgery. 2024. doi:10.1016/j.bjps.2024.06.002

BibTeX
@article{Gallo2024,
  author = {Gallo, Lucas and Rae, Charlene and Kim, Patrick J and Voineskos, Sophocles H and Thoma, Achilles and Pusic, Andrea L and Klassen, Anne F and Cano, Stefan J},
  title = {Establishing test-retest reliability and the smallest detectable change of FACE-Q Aesthetic Module scales},
  journal = {Journal of Plastic, Reconstructive & Aesthetic Surgery},
  year = {2024},
  doi = {10.1016/j.bjps.2024.06.002}
}
Kostenlos starten →