EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte StudieVergleichsstudieOpen Access · CC BY-NC-ND 4.0

A randomized intraindividual comparative study evaluating the effects of two ultrasound-assisted liposuction devices on the abdomen

Erik Agustín Márquez-Gutiérrez, Luis Tamez-Pedroza, Ernesto Demian Morales-Naya, Mario Vélez-Palafox, Gerardo Cuartero-Castro, Noé Zacaula-Juárez, Roberto Sánchez-Sánchez, Maykel González-Torres

Journal of Plastic, Reconstructive & Aesthetic Surgery · 2024

DOI: 10.1016/j.bjps.2024.04.040 ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift Journal of Plastic, Reconstructive & Aesthetic Surgery, 2024. Verfasst von Erik Agustín Márquez-Gutiérrez und 7 weiteren Autor:innen. Beteiligte Einrichtung: Division of Plastic and Reconstructive Surgery, National Center for Research and Care of Burns, National Institute of Rehabilitation, Mexico City, Me…. Hauptthemen laut MEDLINE: Lipectomy. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Ultrasound-assisted liposuction (UAL) has become popular because of its favorable outcomes in fat emulsification, blood loss reduction, and skin tightening. This study aimed to compare the effects of two UAL devices on the abdomen by assessing postsurgery skin biomechanical properties. METHODS: This single-blind, prospective study (2020-2022) involved 13 liposuction procedures performed on patients without chronic diseases. Each patient's abdomen was divided vertically from the xiphoid to the perineum. Vibration amplification of sound energy at resonance (VASER)-assisted liposuction (Solta Medical, Inc., Hayward, CA) was performed on one half, while the other half underwent liposuction with high-frequency ultrasound energy (HEUS)-assisted technology. Skin biomechanical measurements, including distensibility, net elasticity, biological elasticity, hydration, erythema, melanin, and skin firmness, were taken at 12 and 24 months postsurgery, focusing on the anterior abdomen, 8 cm to the right and left of the umbilicus. RESULTS: Analysis of the above skin biomechanical measurements revealed no significant differences between the HEUS and VASER devices, except for skin firmness, which showed a notable increase following HEUS surgery. Patient-perceived clinical differences were assessed via nonvalidated questionnaires, revealing no distinctions between devices. CONCLUSION: Biomechanical skin results post-UAL surgery with these devices on the abdomen were not significantly different, although HEUS revealed increased skin firmness. This suggests that HEUS-assisted technology, akin to other devices, is a viable option for UAL procedures.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

LipectomyHumansFemaleProspective StudiesAdultSingle-Blind MethodMiddle AgedMaleAbdomenUltrasonic TherapySkin Physiological Phenomena

Stichwörter der Autor:innen

Abdominal liposuctionHigh-frequency ultrasound energy (HEUS)Postsurgical outcomesSkin biomechanical propertiesUltrasound-assisted liposuction (UAL)Vibration amplification of sound energy at resonance (VASER)

Autor:innen und Institutionen

  • Division of Plastic and Reconstructive Surgery, National Center for Research and Care of Burns, National Institute of Rehabilitation, Mexico City, Mexico. Electronic address: dr_erikmarquez@hotmail.com.
  • Division of Plastic and Reconstructive Surgery, National Center for Research and Care of Burns, National Institute of Rehabilitation, Mexico City, Mexico.
  • Division Head of Plastic and Reconstructive Surgery, National Center for Research and Care of Burns, National Institute of Rehabilitation, Mexico City, Mexico.
  • Conahcyt & Biotechnology Laboratory, National Center for Research and Care of Burns, National Institute of Rehabilitation, Mexico City, Mexico.
  • Cell Therapy and Regenerative Medicine Tissue Engineering Laboratory, National Institute of Rehabilitation, Mexico City, Mexico.
  • Conahcyt & Biotechnology Laboratory, National Center for Research and Care of Burns, National Institute of Rehabilitation, Mexico City, Mexico. Electronic address: maykel.gonzalez@conahcyt.mx.

Zitieren

APA

Márquez-Gutiérrez, E. A., Tamez-Pedroza, L., Morales-Naya, E. D., Vélez-Palafox, M., Cuartero-Castro, G., Zacaula-Juárez, N., Sánchez-Sánchez, R., & González-Torres, M. (2024). A randomized intraindividual comparative study evaluating the effects of two ultrasound-assisted liposuction devices on the abdomen. Journal of Plastic, Reconstructive & Aesthetic Surgery. https://doi.org/10.1016/j.bjps.2024.04.040

Vancouver

Márquez-Gutiérrez EA, Tamez-Pedroza L, Morales-Naya ED, Vélez-Palafox M, Cuartero-Castro G, Zacaula-Juárez N, et al. A randomized intraindividual comparative study evaluating the effects of two ultrasound-assisted liposuction devices on the abdomen. Journal of Plastic, Reconstructive & Aesthetic Surgery. 2024. doi:10.1016/j.bjps.2024.04.040

BibTeX
@article{MrquezGutirrez2024,
  author = {Márquez-Gutiérrez, Erik Agustín and Tamez-Pedroza, Luis and Morales-Naya, Ernesto Demian and Vélez-Palafox, Mario and Cuartero-Castro, Gerardo and Zacaula-Juárez, Noé and Sánchez-Sánchez, Roberto and González-Torres, Maykel},
  title = {A randomized intraindividual comparative study evaluating the effects of two ultrasound-assisted liposuction devices on the abdomen},
  journal = {Journal of Plastic, Reconstructive & Aesthetic Surgery},
  year = {2024},
  doi = {10.1016/j.bjps.2024.04.040}
}
Kostenlos starten →