How to measure vessel caliber in microsurgery and super-microsurgery? Metrological study of three methods applicable in clinical practice
Journal of Plastic, Reconstructive & Aesthetic Surgery · 2023
DOI: 10.1016/j.bjps.2023.05.014 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Plastic, Reconstructive & Aesthetic Surgery, 2023. Verfasst von Ugo Lancien und 4 weiteren Autor:innen. Beteiligte Einrichtung: Plastic, Reconstructive, and Aesthetic Surgery Unit, Nantes University Hospital, 1 Place Alexis Ricordeau, 44000 Nantes, France; INSERM, UMRS 1229, L…. Hauptthemen laut MEDLINE: Microsurgery, Software. Die Arbeit nennt 4 Literaturangaben.
Abstract (Originalsprache)
INTRODUCTION: The microsurgical literature reports the vascular calibers of the vessels studied even though the method of measurement of these vessels is very rarely reported. MATERIAL AND METHOD: We performed a metrological study evaluating three methods to measure the external calibers of catheters corresponding to microsurgical and super-microsurgical vessels (1.2 mm, 0.8 mm, and 0.6 mm). Six evaluators measured 15 catheters of three different hidden diameters by each of the three methods applicable in clinical practice: standard graduated ruler, Shinwa® micrometric ruler, and ImageJ® software from a photograph. Accuracy and reliability of the measurements were assessed by studying the inter- and intra-rater and inter-method coefficients (variants of the intra-class coefficient (ICC)) and analysis of the IC95% of the ICCs. RESULTS: Intra class correlation ICC "intra-rater" coefficient finds for the standard rule 0.81 [0.65-0.93], Shinwa® rule 0.86 [0.67-0.96], and for the ImageJ® software 0.97 [0.94-0.99]. The "Inter-rater" ICC shows respectively the coefficient 0.51 [0.23 and max 0.93], 0.87 [0.75-0.95], and 0.95 [0.89-0.98]. It appears that the graduated decimeter is the least reliable method of measurement, the Shinwa® ruler presents acceptable reliability but requires the purchase of equipment. The reliability of ImageJ® software is the best and appears to be the most reliable method. CONCLUSION: Our original study, with no equivalent in the scientific literature, demonstrates objectively the great accuracy and reliability of a method of measurement of vascular calibers in micro and super microsurgery using intraoperative photography and the use of free computer software.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Plastic, Reconstructive, and Aesthetic Surgery Unit, Nantes University Hospital, 1 Place Alexis Ricordeau, 44000 Nantes, France; INSERM, UMRS 1229, Laboratory Regenerative Medicine and Skeleton (RMeS), Place Alexis Rico…
- Nantes Université, CHU Nantes, Pôle Hospitalo-Universitaire 11: Santé Publique, Clinique des données, INSERM, CIC 1413, 44000 Nantes, France.
Zitieren
APA
Lancien, U., Goronflot, T., Verdier, J., Kanlagna, A., & Perrot, P. (2023). How to measure vessel caliber in microsurgery and super-microsurgery? Metrological study of three methods applicable in clinical practice. Journal of Plastic, Reconstructive & Aesthetic Surgery. https://doi.org/10.1016/j.bjps.2023.05.014
Vancouver
Lancien U, Goronflot T, Verdier J, Kanlagna A, Perrot P. How to measure vessel caliber in microsurgery and super-microsurgery? Metrological study of three methods applicable in clinical practice. Journal of Plastic, Reconstructive & Aesthetic Surgery. 2023. doi:10.1016/j.bjps.2023.05.014
BibTeX
@article{Lancien2023,
author = {Lancien, Ugo and Goronflot, Thomas and Verdier, Julien and Kanlagna, Anoujat and Perrot, Pierre},
title = {How to measure vessel caliber in microsurgery and super-microsurgery? Metrological study of three methods applicable in clinical practice},
journal = {Journal of Plastic, Reconstructive & Aesthetic Surgery},
year = {2023},
doi = {10.1016/j.bjps.2023.05.014}
}
EUVIMED