PEEK patient-specific implants for orbital reconstruction: accuracy and clinical outcomes
British Journal of Oral and Maxillofacial Surgery · 2026-11 · 64 (9) · 758-766
DOI: 10.1016/j.bjoms.2026.06.005 ↗Kurz gefasst
Fachartikel in der Zeitschrift British Journal of Oral and Maxillofacial Surgery, 2026-11. Verfasst von Luis Fernando de Oliveira Gorla und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnosis and Surgery, Division of Oral and Maxillofacial Surgery, São Paulo State University (UNESP), School of Dentistry, Rua Humaitá…. Hauptthemen laut MEDLINE: Ketones, Orbital Fractures, Polyethylene Glycols, Plastic Surgery Procedures. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 30 Literaturangaben. Gefördert von: Johnson and Johnson, Johnson & Johnson MedTech.
Abstract (Originalsprache)
Orbital fractures represent a common and complex challenge in maxillofacial surgery, with functional and aesthetic sequelae. Advances in computer-aided design and manufacturing, virtual planning, and three-dimensional printing have enabledpatient-specific implants (PSIs). Polyetheretherketone (PEEK), a bioinert polymer with properties similar to cortical bone, has emerged as a suitable material for orbital reconstruction. Surgical navigation has also been advocated to enhance accuracy in challenging regions. This retrospective service evaluation analysed ten patients with unilateral orbital fractures reconstructed using customised PEEK PSIs, placed either with navigation (n = 5) or freehand (n = 5). Orbital volumes were measured preoperatively, after virtual planning, and postoperatively; implant positioning was assessed by translational and rotational deviations; and clinical outcomes were evaluated using standardised ophthalmic and maxillofacial criteria. Fractured orbits were larger than contralateral orbits preoperatively, with postoperative volumes close to those of the intact side in both groups. Planned-treated volume discrepancies were small (navigation median 1.50 cm3, IQR 0.30-1.60; freehand 0.20 cm3, IQR 0.20-0.50; median difference 1.00 cm3, 95% CI -0.30 to 1.60; p = 0.151). Translational deviations remained below 2 mm, while rotational discrepancies were greater without navigation, though not statistically significant. Clinical success was achieved in six of the nine evaluable patients, with persistent diplopia in three cases attributed to traumatic muscle injury rather than implant malposition. PEEK PSIs provided a reliable orbital reconstruction, accurate volume restoration, and favourable clinical outcomes. Customised PEEK PSIs were typically designed and manufactured within 4 weeks after clinical assessment and imaging, consistent with a delayed reconstruction pathway in complex cases. Navigation may enhance intraoperative confidence and refine rotational control; however, no statistically demonstrable advantage over freehand placement was shown in this small exploratory cohort, in which satisfactory outcomes were achieved with both approaches, consistent with the inherent 'one-fit' characteristic of PSI.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Diagnosis and Surgery, Division of Oral and Maxillofacial Surgery, São Paulo State University (UNESP), School of Dentistry, Rua Humaitá 1680, 2° andar, Araraquara, SP 14801-903, Brazil. Electronic address:…
- Department of Oral and Maxillofacial Surgery, Sheffield Teaching Hospitals NHS Foundation Trust, Royal Hallamshire Hospital, Sheffield S10 2JF, United Kingdom. Electronic address: sachin.salvi@sth.nhs.uk.
- Charles Clifford Dental Hospital, Sheffield Teaching Hospitals NHS Foundation Trust, Sheffield S10 2SZ, United Kingdom. Electronic address: harriet.tweedale@sth.nhs.uk.
- Department of Oral and Maxillofacial Surgery, Sheffield Teaching Hospitals NHS Foundation Trust, Royal Hallamshire Hospital, Sheffield S10 2JF, United Kingdom. Electronic address: nicholas.lee@sth.nhs.uk.
Förderung
- Johnson and Johnson
- Johnson & Johnson MedTech
Zitieren
APA
de Oliveira Gorla, L. F., Salvi, S. M., Tweedale, H., & Lee, N. J. (2026). PEEK patient-specific implants for orbital reconstruction: accuracy and clinical outcomes. British Journal of Oral and Maxillofacial Surgery, 64(9), 758-766. https://doi.org/10.1016/j.bjoms.2026.06.005
Vancouver
de Oliveira Gorla LF, Salvi SM, Tweedale H, Lee NJ. PEEK patient-specific implants for orbital reconstruction: accuracy and clinical outcomes. British Journal of Oral and Maxillofacial Surgery. 2026;64(9):758-766. doi:10.1016/j.bjoms.2026.06.005
BibTeX
@article{deOliveiraGorla2026,
author = {de Oliveira Gorla, Luis Fernando and Salvi, Sachin M and Tweedale, Harriet and Lee, Nicholas J},
title = {PEEK patient-specific implants for orbital reconstruction: accuracy and clinical outcomes},
journal = {British Journal of Oral and Maxillofacial Surgery},
year = {2026},
volume = {64},
number = {9},
pages = {758--766},
doi = {10.1016/j.bjoms.2026.06.005}
}
EUVIMED