Operating room noise levels in anaesthesia a systematic review and meta-analysis
British Journal of Anaesthesia · 2026-09
DOI: 10.1016/j.bja.2026.08.053 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift British Journal of Anaesthesia, 2026-09. Verfasst von Asher Dixon und 3 weiteren Autor:innen. Beteiligte Einrichtung: Data Science Institute, University of Technology Sydney, Sydney, NSW, Australia; Mater Research Institute, Brisbane, QLD, Australia; Charles Sturt Un…. Die Arbeit nennt 77 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
BACKGROUND: Intraoperative noise is an occupational hazard with the potential to compromise anaesthetist performance and patient safety. The WHO recommends hospital sound exposure ≤ 35 dB LAeq (A-weighted equivalent continuous sound level), yet noise levels routinely exceed this level. This systematic review and meta-analysis aimed to determine intraoperative noise levels worldwide. METHODS: Five databases were searched from inception to May 2026, in accordance with Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Studies were eligible for inclusion if they included surgical specialty and a measure of noise sampled recorded with validated sound metres. Studies were eligible for meta-analysis if they included a mean time-weighted average. Two authors undertook searches and risk-of-bias assessment. Meta-regression estimated pooled means, heterogeneity, and variance. RESULTS: Fifty studies met the inclusion criteria in the systematic review, with 28 studies providing 43 unique datasets subclassified by type of surgical procedure for analysis. The pooled random-effects mean intraoperative noise level was 70.7 A-weighted dB [dB(A)] (95% CI 69.0-72.3). Subgroup analysis demonstrated the highest exposures in otolaryngology at 78.8 dB(A) (95% CI 72.8-84.7) and orthopaedics at 73.3 dB(A) (95% CI 68.9-77.8). Meta-regression confirmed surgical specialty as a significant predictor of mean exposure (Q=25.8, degrees of freedom=6, P=0.0002). CONCLUSIONS: Anaesthetists are consistently exposed to intraoperative sound levels exceeding WHO guidelines, particularly in high-intensity specialties such as orthopaedics and otolaryngology. These findings provide a specialty-specific synthesis of noise exposure and highlight the need for targeted interventions, standardised measurement, and research linking exposure to clinical outcomes.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Data Science Institute, University of Technology Sydney, Sydney, NSW, Australia; Mater Research Institute, Brisbane, QLD, Australia; Charles Sturt University, Bathurst, NSW, Australia. Electronic address: asher.luc.dixo…
- University of Queensland, Brisbane, QLD, Australia; Royal Brisbane and Women's Hospital, Brisbane, QLD, Australia.
- University of Queensland, Brisbane, QLD, Australia; Department of Anaesthesia, Toowoomba Hospital, Toowoomba, QLD, Australia.
- Data Science Institute, University of Technology Sydney, Sydney, NSW, Australia; Charles Sturt University, Bathurst, NSW, Australia.
Zitieren
APA
Dixon, A., Sieben, N. A., Smith, S., & Sun, J. (2026). Operating room noise levels in anaesthesia a systematic review and meta-analysis. British Journal of Anaesthesia. https://doi.org/10.1016/j.bja.2026.08.053
Vancouver
Dixon A, Sieben NA, Smith S, Sun J. Operating room noise levels in anaesthesia a systematic review and meta-analysis. British Journal of Anaesthesia. 2026. doi:10.1016/j.bja.2026.08.053
BibTeX
@article{Dixon2026,
author = {Dixon, Asher and Sieben, Nicolas A and Smith, Samuel and Sun, Jing},
title = {Operating room noise levels in anaesthesia a systematic review and meta-analysis},
journal = {British Journal of Anaesthesia},
year = {2026},
doi = {10.1016/j.bja.2026.08.053}
}
EUVIMED