Closed-loop systems for automated hypnotic drug delivery during general anaesthesia: a systematic review and meta-analysis
British Journal of Anaesthesia · 2026
DOI: 10.1016/j.bja.2026.03.020 ↗Kurz gefasst
Systematische Übersicht in der Zeitschrift British Journal of Anaesthesia, 2026. Verfasst von Vitor Alves Felippe und 9 weiteren Autor:innen. Beteiligte Einrichtung: Instituto Nacional de Câncer (INCA), Rio de Janeiro, Brazil. Electronic address: vitorfelippe2@gmail.com. Hauptthemen laut MEDLINE: Anesthesia, General, Hypnotics and Sedatives, Drug Delivery Systems. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 49 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Closed-loop systems for automated hypnotic delivery integrate continuous bispectral index (BIS) monitoring with controller algorithms to adjust infusion rates in real time. Unlike earlier syntheses that focused on aggregate control metrics, we frame anaesthetic depth as an asymmetric risk problem by separating exposure to potentially inadequate anaesthesia from exposure to excessive depth of anaesthesia. METHODS: This PROSPERO-registered systematic review (CRD420251208039) searched PubMed, Embase, Cochrane CENTRAL, and Web of Science through November 2025. Randomised trials comparing BIS-guided closed-loop systems with clinician-directed manual control in adult noncardiac surgery were included. The primary outcome was the proportion of time within 10 BIS units of the target. RESULTS: Seventeen trials encompassing 1898 patients were included. Closed-loop systems increased time within the target BIS range by 17.6% (95% confidence interval [CI] 11.8-23.5; P 60 was unchanged (MD -0.8%; 95% CI -2.6 to 1.0; P=0.38). Controller performance metrics favoured automation (wobble, MDAPE, global score; all P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Instituto Nacional de Câncer (INCA), Rio de Janeiro, Brazil. Electronic address: vitorfelippe2@gmail.com.
- Centro Universitário Christus, Fortaleza, Brazil.
- Universidade Federal do Amazonas, Manaus, Brazil.
- Universidade Federal do Rio Grande do Sul, Porto Alegre, Brazil.
- Universidade Federal da Fronteira Sul, Passo Fundo, Brazil.
- Universidade Federal do Estado do Rio de Janeiro (UNIRIO), Rio de Janeiro, Brazil.
Zitieren
APA
Felippe, V. A., Dias, H. S., da Hora, D. A. B., Wegner, B. F. M., Wegner, G. R. M., González, G. L., Piredda, G. V., Bezerra, F. J. L., Bersot, C. D. A., & Lessa, M. A. (2026). Closed-loop systems for automated hypnotic drug delivery during general anaesthesia: a systematic review and meta-analysis. British Journal of Anaesthesia. https://doi.org/10.1016/j.bja.2026.03.020
Vancouver
Felippe VA, Dias HS, da Hora DAB, Wegner BFM, Wegner GRM, González GL, et al. Closed-loop systems for automated hypnotic drug delivery during general anaesthesia: a systematic review and meta-analysis. British Journal of Anaesthesia. 2026. doi:10.1016/j.bja.2026.03.020
BibTeX
@article{Felippe2026,
author = {Felippe, Vitor Alves and Dias, Hiorrana Sousa and da Hora, David Abraham Batista and Wegner, Bruno Francisco Minetto and Wegner, Gustavo Roberto Minetto and González, Gabriel Lemos and Piredda, Gabriel Vieira and Bezerra, Francisco José Lucena and Bersot, Carlos Darcy Alves and Lessa, Marcos A},
title = {Closed-loop systems for automated hypnotic drug delivery during general anaesthesia: a systematic review and meta-analysis},
journal = {British Journal of Anaesthesia},
year = {2026},
doi = {10.1016/j.bja.2026.03.020}
}
EUVIMED