Accuracy of continuous glucose monitoring during noncardiac surgery: a prospective, blinded observational multicentre cohort study
British Journal of Anaesthesia · 2025-10 · 135 (4) · 912-919
DOI: 10.1016/j.bja.2025.05.057 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift British Journal of Anaesthesia, 2025-10. Verfasst von Henrike Janssen und 13 weiteren Autor:innen. Beteiligte Einrichtung: Translational Medicine and Therapeutics, William Harvey Research Institute, Queen Mary University of London, London, UK. Hauptthemen laut MEDLINE: Blood Glucose, Monitoring, Intraoperative, Hyperglycemia, Surgical Procedures, Operative. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Efficacy and Mechanism Evaluation Programme, British Heart Foundation, National Institute for Health and Care Research.
Abstract (Originalsprache)
BACKGROUND: Hyperglycaemia after noncardiac surgery is rarely detected outside of the critical care environment, yet occurs commonly and is associated with excess complications including infections and myocardial injury. Systematic, prospectively collected data regarding the accuracy of continuous glucose monitoring commenced immediately before surgery and throughout the early perioperative period are lacking. METHODS: We prospectively enrolled patients aged >50 yr undergoing noncardiac surgery who required at least 24 h of hospital stay. We used real-time continuous glucose monitoring (Dexcom G7 sensor, placed in the upper outer arm) (Dexcom, San Diego, CA, USA) with reference values from arterial blood glucose measurements by amperometry. The primary outcome was the overall mean difference (bias) before surgery, at end of surgery, and 24 h after surgery (Bland-Altman analysis). Secondary outcomes included the mean absolute relative difference and surveillance error grid analyses. RESULTS: We compared paired blood (73% arterial) and continuous glucose monitoring glucose values at each prespecified timepoint in 118 participants (64/118 [54%] female; mean age: 66 [range: 51-89] yr; 25% with diabetes mellitus). The overall bias between continuous glucose monitoring and blood glucose from measurements at each of the three timepoints in the first 24 h after induction of anaesthesia was 0.38 mM (95% confidence interval [95% CI]: 0.23-0.53; n=340 paired readings). Bias decreased from before the start of surgery (1.08 mM [95% CI: 0.87-1.29]; n=116) to 0.15 mM at the end of surgery (95% CI: -0.15 to 0.46; n=113). Mean absolute relative difference ranged from 12.0% to 18.3%. Error grid analyses found that >98% continuous glucose monitoring values were within acceptable risk ranges. CONCLUSIONS: The accuracy of state-of-the-art continuous glucose monitoring is sufficient for perioperative use and could enhance perioperative surveillance of dysglycaemia. CLINICAL TRIAL REGISTRATION: ISRCTN46862025.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Translational Medicine and Therapeutics, William Harvey Research Institute, Queen Mary University of London, London, UK.
- Translational Medicine and Therapeutics, William Harvey Research Institute, Queen Mary University of London, London, UK; King Saud bin Abdulaziz University for Health Sciences, Riyadh, Saudi Arabia; King Abdullah Intern…
- Warwick Clinical Trials Unit, University of Warwick, Warwick, UK.
- University Hospitals Birmingham NHS Trust, Birmingham, UK.
- Croydon University Hospital, Croydon, Croydon, UK.
- St James's University Hospital, Leeds, UK.
Förderung
- Efficacy and Mechanism Evaluation Programme
- British Heart Foundation
- National Institute for Health and Care Research
- British Journal of Anaesthesia
- Royal College of Anaesthetists
Zitieren
APA
Janssen, H., Dias, P., Ahuja, S., Alharbi, S., Hiller, L., Khan, K., Iyer, K., Sundar, A., Abousharkh, I., Thomas, C., Jhanji, S., Oliver, N. S., Ackland, G. L., & GlucoVITAL Investigators (2025). Accuracy of continuous glucose monitoring during noncardiac surgery: a prospective, blinded observational multicentre cohort study. British Journal of Anaesthesia, 135(4), 912-919. https://doi.org/10.1016/j.bja.2025.05.057
Vancouver
Janssen H, Dias P, Ahuja S, Alharbi S, Hiller L, Khan K, et al. Accuracy of continuous glucose monitoring during noncardiac surgery: a prospective, blinded observational multicentre cohort study. British Journal of Anaesthesia. 2025;135(4):912-919. doi:10.1016/j.bja.2025.05.057
BibTeX
@article{Janssen2025,
author = {Janssen, Henrike and Dias, Priyanthi and Ahuja, Sanjali and Alharbi, Saja and Hiller, Louise and Khan, Kamran and Iyer, Karthik and Sundar, Ashok and Abousharkh, Islam and Thomas, Caroline and Jhanji, Shaman and Oliver, Nick S and Ackland, Gareth L and GlucoVITAL Investigators, GlucoVITAL Investigators},
title = {Accuracy of continuous glucose monitoring during noncardiac surgery: a prospective, blinded observational multicentre cohort study},
journal = {British Journal of Anaesthesia},
year = {2025},
volume = {135},
number = {4},
pages = {912--919},
doi = {10.1016/j.bja.2025.05.057}
}
EUVIMED