EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Altered thrombin generation with prothrombin complex concentrate is not detected by viscoelastic testing: an in vitro study

Nikolaus Hofmann, Herbert Schöchl, Johannes Zipperle, Johannes Gratz, Felix C F Schmitt, Daniel Oberladstätter

British Journal of Anaesthesia · 2025

DOI: 10.1016/j.bja.2024.10.047 ↗

Kurz gefasst

Fachartikel in der Zeitschrift British Journal of Anaesthesia, 2025. Verfasst von Nikolaus Hofmann und 5 weiteren Autor:innen. Beteiligte Einrichtung: Medical University of Vienna, Department of Anaesthesia, Intensive Care Medicine and Pain Medicine, Division of General Anaesthesia and Intensive Car…. Hauptthemen laut MEDLINE: Thrombin, Blood Coagulation Factors, Thrombelastography. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ludwig Boltzmann Institute for Traumatology The Research Center in Cooperation with AUVA.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Bleeding guidelines currently recommend use of viscoelastic testing (VET) to direct haemostatic resuscitation in severe haemorrhage. However, VET-derived parameters of clot initiation, such as clotting time (CT) and activated clotting time (ACT), might not adequately reflect a clinically relevant interaction of procoagulant and anticoagulant activity, as revealed by thrombin generation assays. The aim of this study was to evaluate the ability of CT and ACT to indicate thrombin generation activity. METHODS: Citrated whole blood obtained from 13 healthy volunteers underwent a 50% crystalloid dilution (DL-50%), followed by spiking with four-factor prothrombin complex concentrate (DL-50% + 4F-PCC). Changes in thrombin generation activity were compared with the VET parameters CT and ACT derived from four commercially available viscoelastic devices (ROTEM® Delta, ClotPro®, TEG®6s, and Quantra®) and standard coagulation tests. RESULTS: Dilution of whole blood resulted in a marked increase in velocity index, peak height, and endogenous thrombin potential (all P

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ThrombinBlood Coagulation FactorsThrombelastographyHumansMaleAdultFemaleBlood Coagulation TestsBlood CoagulationYoung AdultMiddle AgedHealthy VolunteersWhole Blood Coagulation Time

Stichwörter der Autor:innen

point-of-care coagulation testingprothrombin complex concentratethrombin generationtrauma-induced coagulopathyviscoelastic testing

Substanzen

Thrombinprothrombin complex concentratesBlood Coagulation Factors

Autor:innen und Institutionen

  • Medical University of Vienna, Department of Anaesthesia, Intensive Care Medicine and Pain Medicine, Division of General Anaesthesia and Intensive Care Medicine, Vienna, Austria; Ludwig Boltzmann Institute for Traumatolo…
  • Ludwig Boltzmann Institute for Traumatology, The Research Center in Cooperation with AUVA, Vienna, Austria; Department of Anesthesiology and Intensive Care Medicine AUVA Trauma Center Salzburg, Academic Teaching Hospita…
  • Ludwig Boltzmann Institute for Traumatology, The Research Center in Cooperation with AUVA, Vienna, Austria.
  • Medical University of Vienna, Department of Anaesthesia, Intensive Care Medicine and Pain Medicine, Division of General Anaesthesia and Intensive Care Medicine, Vienna, Austria. Electronic address: johannes.gratz@meduni…
  • Department of Anesthesiology, Heidelberg University Hospital, Heidelberg, Germany.

Förderung

  • Ludwig Boltzmann Institute for Traumatology The Research Center in Cooperation with AUVA

Zitieren

APA

Hofmann, N., Schöchl, H., Zipperle, J., Gratz, J., Schmitt, F. C. F., & Oberladstätter, D. (2025). Altered thrombin generation with prothrombin complex concentrate is not detected by viscoelastic testing: an in vitro study. British Journal of Anaesthesia. https://doi.org/10.1016/j.bja.2024.10.047

Vancouver

Hofmann N, Schöchl H, Zipperle J, Gratz J, Schmitt FCF, Oberladstätter D. Altered thrombin generation with prothrombin complex concentrate is not detected by viscoelastic testing: an in vitro study. British Journal of Anaesthesia. 2025. doi:10.1016/j.bja.2024.10.047

BibTeX
@article{Hofmann2025,
  author = {Hofmann, Nikolaus and Schöchl, Herbert and Zipperle, Johannes and Gratz, Johannes and Schmitt, Felix C F and Oberladstätter, Daniel},
  title = {Altered thrombin generation with prothrombin complex concentrate is not detected by viscoelastic testing: an in vitro study},
  journal = {British Journal of Anaesthesia},
  year = {2025},
  doi = {10.1016/j.bja.2024.10.047}
}
Kostenlos starten →