EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte Studie

Effect of driving pressure-guided positive end-expiratory pressure on postoperative pulmonary complications in patients undergoing laparoscopic or robotic surgery: a randomised controlled trial

Yoon Jung Kim, Bo Rim Kim, Hee Won Kim, Ji-Yoon Jung, Hye-Yeon Cho, Jeoung-Hwa Seo, Won Ho Kim, Hee-Soo Kim, Suhyun Hwangbo, Hyun-Kyu Yoon

British Journal of Anaesthesia · 2023-11 · 131 (5) · 955-965

DOI: 10.1016/j.bja.2023.08.007 ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift British Journal of Anaesthesia, 2023-11. Verfasst von Yoon Jung Kim und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology and Pain Medicine, Seoul National University College of Medicine, Seoul, Republic of Korea; Department of Anesthesiology…. Hauptthemen laut MEDLINE: Robotic Surgical Procedures, Laparoscopy. Die Arbeit wurde bisher 45-mal zitiert (Crossref) und nennt 41 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Individualised positive end-expiratory pressure (PEEP) improves respiratory mechanics. However, whether PEEP reduces postoperative pulmonary complications (PPCs) remains unclear. We investigated whether driving pressure-guided PEEP reduces PPCs after laparoscopic/robotic abdominal surgery. METHODS: This single-centre, randomised controlled trial enrolled patients at risk for PPCs undergoing laparoscopic or robotic lower abdominal surgery. The individualised group received driving pressure-guided PEEP, whereas the comparator group received 5 cm H2O fixed PEEP during surgery. Both groups received a tidal volume of 8 ml kg-1 ideal body weight. The primary outcome analysed per protocol was a composite of pulmonary complications (defined by pre-specified clinical and radiological criteria) within 7 postoperative days after surgery. RESULTS: Some 384 patients (median age: 67 yr [inter-quartile range: 61-73]; 66 [18%] female) were randomised. Mean (standard deviation) PEEP in patients randomised to individualised PEEP (n=178) was 13.6 cm H2O (2.1). Individualised PEEP resulted in lower mean driving pressures (14.7 cm H2O [2.6]), compared with 185 patients randomised to standard PEEP (18.4 cm H2O [3.2]; mean difference: -3.7 cm H2O [95% confidence interval (CI): -4.3 to -3.1 cm H2O]; P

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Robotic Surgical ProceduresLaparoscopyHumansFemaleAgedMaleLungPositive-Pressure RespirationPostoperative ComplicationsTidal Volume

Stichwörter der Autor:innen

driving pressurelung protective ventilationpneumoperitoneumpositive end-expiratory pressurepostoperative pulmonary complications

Autor:innen und Institutionen

  • Department of Anesthesiology and Pain Medicine, Seoul National University College of Medicine, Seoul, Republic of Korea; Department of Anesthesiology and Pain Medicine, Seoul National University Hospital, Seoul, Republi…
  • Department of Anesthesiology and Pain Medicine, Korea University College of Medicine, Korea University Guro Hospital, Seoul, Republic of Korea.
  • Department of Anesthesiology and Pain Medicine, Seoul National University Hospital, Seoul, Republic of Korea.
  • Department of Genomic Medicine, Seoul National University Hospital, Seoul, Republic of Korea.

Zitieren

APA

Kim, Y. J., Kim, B. R., Kim, H. W., Jung, J. Y., Cho, H. Y., Seo, J. H., Kim, W. H., Kim, H. S., Hwangbo, S., & Yoon, H. K. (2023). Effect of driving pressure-guided positive end-expiratory pressure on postoperative pulmonary complications in patients undergoing laparoscopic or robotic surgery: a randomised controlled trial. British Journal of Anaesthesia, 131(5), 955-965. https://doi.org/10.1016/j.bja.2023.08.007

Vancouver

Kim YJ, Kim BR, Kim HW, Jung JY, Cho HY, Seo JH, et al. Effect of driving pressure-guided positive end-expiratory pressure on postoperative pulmonary complications in patients undergoing laparoscopic or robotic surgery: a randomised controlled trial. British Journal of Anaesthesia. 2023;131(5):955-965. doi:10.1016/j.bja.2023.08.007

BibTeX
@article{Kim2023,
  author = {Kim, Yoon Jung and Kim, Bo Rim and Kim, Hee Won and Jung, Ji-Yoon and Cho, Hye-Yeon and Seo, Jeoung-Hwa and Kim, Won Ho and Kim, Hee-Soo and Hwangbo, Suhyun and Yoon, Hyun-Kyu},
  title = {Effect of driving pressure-guided positive end-expiratory pressure on postoperative pulmonary complications in patients undergoing laparoscopic or robotic surgery: a randomised controlled trial},
  journal = {British Journal of Anaesthesia},
  year = {2023},
  volume = {131},
  number = {5},
  pages = {955--965},
  doi = {10.1016/j.bja.2023.08.007}
}
Kostenlos starten →