EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Real-time temperature correction for magnetoresistive biosensors integrated with temperature modulator

Songeun Kim, Shan X Wang, Jung-Rok Lee

Biosensors and Bioelectronics: X · 2023-09 · 14 · 100356

DOI: 10.1016/j.biosx.2023.100356 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics: X, 2023-09. Verfasst von Songeun Kim und 2 weiteren Autor:innen. Beteiligte Einrichtung: Division of Mechanical and Biomedical Engineering, Ewha Womans University, Seoul, 03760, South Korea. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NCI NIH HHS, NIDDK NIH HHS, National Institutes of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Magnetoresistance-based biosensors utilize changes in electrical resistance upon varying magnetic fields to measure biological molecules or events involved with magnetic tags. However, electrical resistance fluctuates with temperature. To decouple unwanted temperature-dependent signals from the signal of interest, various methods have been proposed to correct signals from magnetoresistance-based biosensors. Yet, there is still a need for a temperature correction method capable of instantaneously correcting signals from all sensors in an array, as multiple biomarkers need to be detected simultaneously with a group of sensors in a central laboratory or point-of-care setting. Here we report a giant magnetoresistive biosensor system that enables real-time temperature correction for individual sensors using temperature correction coefficients obtained through a temperature sweep generated by an integrated temperature modulator. The algorithm with individual temperature correction coefficients obviously outperformed that using the average temperature correction coefficient. Further, temperature regulation did not eliminate temperature-dependent signals completely. To demonstrate that the method can be used in biomedical applications where large temperature variations are involved, binding kinetics experiments and melting curve analysis were conducted with the temperature correction method. The method successfully removed all temperature-dependent artifacts and thus produced more precise kinetic parameters and melting temperatures of DNA hybrids.

Schlagwörter

Stichwörter der Autor:innen

GMR biosensorsKineticsMagnetoresistanceMelting curve analysisTemperature compensationThermoelectric effect

Autor:innen und Institutionen

  • Division of Mechanical and Biomedical Engineering, Ewha Womans University, Seoul, 03760, South Korea.
  • Graduate Program in Smart Factory, Ewha Womans University, Seoul, 03760, South Korea.
  • Department of Materials Science and Engineering, Stanford University, Stanford, CA, 93405, USA.
  • Department of Electrical Engineering, Stanford University, Stanford, CA, 93405, USA.

Förderung

  • NCI NIH HHS
  • NIDDK NIH HHS
  • National Institutes of Health
  • National Research Foundation of Korea

Zitieren

APA

Kim, S., Wang, S. X., & Lee, J. R. (2023). Real-time temperature correction for magnetoresistive biosensors integrated with temperature modulator. Biosensors and Bioelectronics: X, 14, 100356. https://doi.org/10.1016/j.biosx.2023.100356

Vancouver

Kim S, Wang SX, Lee JR. Real-time temperature correction for magnetoresistive biosensors integrated with temperature modulator. Biosensors and Bioelectronics: X. 2023;14:100356. doi:10.1016/j.biosx.2023.100356

BibTeX
@article{Kim2023,
  author = {Kim, Songeun and Wang, Shan X and Lee, Jung-Rok},
  title = {Real-time temperature correction for magnetoresistive biosensors integrated with temperature modulator},
  journal = {Biosensors and Bioelectronics: X},
  year = {2023},
  volume = {14},
  pages = {100356},
  doi = {10.1016/j.biosx.2023.100356}
}
Kostenlos starten →