A bacteriophage-functionalized parylene interface for rapid and direct real-time capacitive detection of Escherichia coli

Reuben Wang, Chien-Fang Ding, Shih-Yu Chen, Hsien-Yeh Chen, Po-Chuan Hsieh

Biosensors and Bioelectronics · 2027-02 · 318 · 119431

DOI: 10.1016/j.bios.2026.119431 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2027-02. Verfasst von Reuben Wang und 4 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Food Safety and Health, College of Public Health, National Taiwan University, Taipei, Taiwan; Master of Public Health Program (MPH), Col…. Die Arbeit nennt 33 Literaturangaben. Gefördert von: National Science and Technology Council.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The rapid and reliable detection of foodborne pathogenic bacteria is critical for food safety and public health. Here, we report a bacteriophage-functionalized parylene H interface for rapid, direct, label-free, reagent-free, and real-time capacitive detection of Escherichia coli. An interdigitated electrode fabricated on copper-coated glass by UV laser ablation enabled uniform deposition of a single ultrathin parylene H layer, serving simultaneously as a dielectric insulator and a reactive surface for bacteriophage immobilization. The biosensor detected E. coli without cell lysis or signal amplification, with a linear range of 8 × 102 to 8 × 106 CFU/mL in the sensing chamber and a detection limit of 40 CFU/mL (S/N > 3) at 100 kHz and 0.5 V. It exhibited high selectivity against four non-target E. coli strains, Salmonella enterica, and Staphylococcus aureus, with the largest non-target response being only 2.30% of the target response. In commercial apple and orange juices, recoveries of 91.5-105.8% were achieved. The complete three-stage detection process was completed within 40 min. This work establishes a simple single-layer parylene H strategy for capacitive biosensing and offers a promising route for portable food safety monitoring.

Schlagwörter

Stichwörter der Autor:innen

Capacitive biosensorFood safetyInterdigitated electrodeLabel-free detectionParylene H

Autor:innen und Institutionen

  • Institute of Food Safety and Health, College of Public Health, National Taiwan University, Taipei, Taiwan; Master of Public Health Program (MPH), College of Public Health, National Taiwan University, Taipei, Taiwan.
  • Department of Biomechatronics Engineering, National Taiwan University, Taipei, 106319, Taiwan.
  • Department of Chemical Engineering, National Taiwan University, Taipei, 106319, Taiwan.
  • Department of Biomechatronics Engineering, National Taiwan University, Taipei, 106319, Taiwan. Electronic address: hsiehpc@ntu.edu.tw.

Förderung

  • National Science and Technology Council

Zitieren

APA

Wang, R., Ding, C. F., Chen, S. Y., Chen, H. Y., & Hsieh, P. C. (2027). A bacteriophage-functionalized parylene interface for rapid and direct real-time capacitive detection of Escherichia coli. Biosensors and Bioelectronics, 318, 119431. https://doi.org/10.1016/j.bios.2026.119431

Vancouver

Wang R, Ding CF, Chen SY, Chen HY, Hsieh PC. A bacteriophage-functionalized parylene interface for rapid and direct real-time capacitive detection of Escherichia coli. Biosensors and Bioelectronics. 2027;318:119431. doi:10.1016/j.bios.2026.119431

BibTeX
@article{Wang2027,
  author = {Wang, Reuben and Ding, Chien-Fang and Chen, Shih-Yu and Chen, Hsien-Yeh and Hsieh, Po-Chuan},
  title = {A bacteriophage-functionalized parylene interface for rapid and direct real-time capacitive detection of Escherichia coli},
  journal = {Biosensors and Bioelectronics},
  year = {2027},
  volume = {318},
  pages = {119431},
  doi = {10.1016/j.bios.2026.119431}
}
Kostenlos starten →