Bead-supported orthogonal colocalized proximity extension assay: multiplex protein detection toward early diagnostic applications for urolithiasis
Biosensors and Bioelectronics · 2027-02 · 318 · 119390
DOI: 10.1016/j.bios.2026.119390 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2027-02. Verfasst von Zhiwei Jiang und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Urology, the First Affiliated Hospital of Anhui Medical University, Hefei, 230000, China; Institute of Urology, Anhui Medical Universit…. Die Arbeit nennt 42 Literaturangaben.
Abstract (Originalsprache)
Multiplexed, simple and rapid protein detection facilitates disease-related diagnostic workflows. Herein, we develop a bead-supported orthogonal colocalized proximity extension assay (Ort-CPEA) that enables fast, sensitive, one-pot quantification of three protein biomarkers for early-stage urolithiasis diagnosis. The colocalized PEA design accelerates target-protein recognition, yielding an observed kinetic rate constant 10-fold higher than that of conventional PEA. By integrating the Nt. BstNBI-driven DNA orthogonal reaction, our method achieves reliable multiplex protein detection. Ort-CPEA delivers superior analytical sensitivity for urolithiasis-associated protein markers, with limits of detection of 9.1 fg/mL for THP, 18.1 fg/mL for OPN, and 44.3 fg/mL for Fetuin-A, corresponding to an approximately 1000-fold sensitivity improvement over standard ELISA. Clinical urine-sample analysis validates the practical utility of Ort-CPEA for early urolithiasis diagnosis, yielding an area under the receiver-operating-characteristic curve (AUC) of 0.9900. This study presents a novel methodological tool for multiplex protein measurement and early-stage urolithiasis diagnosis.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Urology, the First Affiliated Hospital of Anhui Medical University, Hefei, 230000, China; Institute of Urology, Anhui Medical University, Hefei, 230000, China; Anhui Provincial Key Laboratory of Urological…
- Department of Laboratory Medicine, Chongqing Hospital of Traditional Chinese Medicine, Chongqing, 400021, China. Electronic address: zhoudandancq@163.com.
Zitieren
APA
Jiang, Z., Yang, Y., He, Q., Huang, Y., Zhou, D., Zhang, L., & Hao, Z. (2027). Bead-supported orthogonal colocalized proximity extension assay: multiplex protein detection toward early diagnostic applications for urolithiasis. Biosensors and Bioelectronics, 318, 119390. https://doi.org/10.1016/j.bios.2026.119390
Vancouver
Jiang Z, Yang Y, He Q, Huang Y, Zhou D, Zhang L, et al. Bead-supported orthogonal colocalized proximity extension assay: multiplex protein detection toward early diagnostic applications for urolithiasis. Biosensors and Bioelectronics. 2027;318:119390. doi:10.1016/j.bios.2026.119390
BibTeX
@article{Jiang2027,
author = {Jiang, Zhiwei and Yang, Yuehan and He, Qiushi and Huang, Yanheng and Zhou, Dandan and Zhang, Lvwen and Hao, Zongyao},
title = {Bead-supported orthogonal colocalized proximity extension assay: multiplex protein detection toward early diagnostic applications for urolithiasis},
journal = {Biosensors and Bioelectronics},
year = {2027},
volume = {318},
pages = {119390},
doi = {10.1016/j.bios.2026.119390}
}
EUVIMED