EUVIMEDEUVIMED entdecken
EvaluationsstudieOpen Access · CC BY 4.0

A one-step functionalized 3D-printed electrochemical biosensor for serotype-selective detection of dengue NS1

Dayenny L D'Amato, Natália M Caldas, Lucas V de Faria, Carolina B P Ligiero, Ana Beatriz C Souza, Camille C de Mello, Guilherme P Oliveira, Rafael M Dornellas, Célia M Ronconi

Biosensors and Bioelectronics · 2027-02 · 317 · 119362

DOI: 10.1016/j.bios.2026.119362 ↗

Kurz gefasst

Evaluationsstudie in der Zeitschrift Biosensors and Bioelectronics, 2027-02. Verfasst von Dayenny L D'Amato und 8 weiteren Autor:innen. Beteiligte Einrichtung: Departamento de Química Inorgânica, Universidade Federal Fluminense, Campus do Valonguinho, Outeiro São João Batista s/n, Centro, Niterói, RJ, 24020-…. Hauptthemen laut MEDLINE: Viral Nonstructural Proteins, Biosensing Techniques, Dengue Virus, Electrochemical Techniques. Die Arbeit nennt 66 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Council for Scientific and Technological Development, Carlos Chagas Filho Foundation for Research Support of Rio de Janeiro State, Coordination for the improvement of Higher Education Personnel.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Rapid and selective detection of dengue virus serotypes remains challenging because of the co-circulation of antigenically related arboviruses. We developed a fully 3D-printed electrochemical biosensor for dengue virus serotype 2 non-structural protein 1 (DENV-2 NS1). The integrated three-electrode platform incorporated a graphite/polylactic acid working electrode modified in a single drop-casting step with preassembled monoclonal antibody-gold nanoparticle conjugates (mAb-AuNP). DENV-2 NS1 binding was monitored by cyclic voltammetry using [Fe(CN)6]3-/4- as a redox probe; immunocomplex formation partially blocked interfacial electron transfer and decreased the cathodic peak current. The response stabilized after 15 min and was linear from 0.15 to 0.75 μg L-1 (1.75-8.74 pM), with R2 = 0.9922 and a limit of detection of 0.061 μg L-1 (0.71 pM). Three independently prepared biosensors showed a relative standard deviation of 3.4%, indicating good fabrication reproducibility. The immunosensor produced a substantially greater response to DENV-2 NS1 than to DENV-1 NS1, Zika virus NS1, or chikungunya virus E2 protein. In 100-fold-diluted human serum spiked at 0.15 and 0.25 μg L-1, standard-addition analysis yielded recoveries of 106.0 ± 1.3% and 97.7 ± 1.1%, respectively. These findings demonstrate that one-step mAb-AuNP functionalization of fully 3D-printed electrodes provides a rapid, reproducible, and serotype-selective approach to NS1 detection, warranting further validation with clinical samples.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Viral Nonstructural ProteinsBiosensing TechniquesDengue VirusElectrochemical TechniquesDengueHumansGoldPrinting, Three-DimensionalMetal NanoparticlesLimit of DetectionAntibodies, ImmobilizedSerogroupImmunoassayGraphiteReproducibility of ResultsAntibodies, Monoclonal

Stichwörter der Autor:innen

3D-printed electrodeAntibody–gold nanoparticle conjugatesDengue virus serotype 2 (DENV-2)Electrochemical biosensorNS1 proteinSerotype-selective detection

Substanzen

Viral Nonstructural ProteinsGoldNS1 protein, Dengue virus type 2Antibodies, ImmobilizedGraphiteAntibodies, Monoclonal

Autor:innen und Institutionen

  • Departamento de Química Inorgânica, Universidade Federal Fluminense, Campus do Valonguinho, Outeiro São João Batista s/n, Centro, Niterói, RJ, 24020-150, Brazil.
  • Departamento de Química Analítica, Universidade Federal Fluminense, Campus do Valonguinho, Outeiro São João Batista s/n, Centro, Niterói, RJ, 24020-150, Brazil.
  • Departamento de Química Analítica, Universidade Federal do Rio de Janeiro, Campus Fundão, Avenida Athos da Silveira Ramos 149, Cidade Universitária, Rio de Janeiro, RJ, 21941-590, Brazil.
  • Departamento de Química Analítica, Universidade Federal Fluminense, Campus do Valonguinho, Outeiro São João Batista s/n, Centro, Niterói, RJ, 24020-150, Brazil. Electronic address: rafaeldornellas@id.uff.br.
  • Departamento de Química Inorgânica, Universidade Federal Fluminense, Campus do Valonguinho, Outeiro São João Batista s/n, Centro, Niterói, RJ, 24020-150, Brazil. Electronic address: cmronconi@id.uff.br.

Förderung

  • National Council for Scientific and Technological Development
  • Carlos Chagas Filho Foundation for Research Support of Rio de Janeiro State
  • Coordination for the improvement of Higher Education Personnel

Zitieren

APA

D'Amato, D. L., Caldas, N. M., de Faria, L. V., Ligiero, C. B. P., Souza, A. B. C., de Mello, C. C., Oliveira, G. P., Dornellas, R. M., & Ronconi, C. M. (2027). A one-step functionalized 3D-printed electrochemical biosensor for serotype-selective detection of dengue NS1. Biosensors and Bioelectronics, 317, 119362. https://doi.org/10.1016/j.bios.2026.119362

Vancouver

D'Amato DL, Caldas NM, de Faria LV, Ligiero CBP, Souza ABC, de Mello CC, et al. A one-step functionalized 3D-printed electrochemical biosensor for serotype-selective detection of dengue NS1. Biosensors and Bioelectronics. 2027;317:119362. doi:10.1016/j.bios.2026.119362

BibTeX
@article{DAmato2027,
  author = {D'Amato, Dayenny L and Caldas, Natália M and de Faria, Lucas V and Ligiero, Carolina B P and Souza, Ana Beatriz C and de Mello, Camille C and Oliveira, Guilherme P and Dornellas, Rafael M and Ronconi, Célia M},
  title = {A one-step functionalized 3D-printed electrochemical biosensor for serotype-selective detection of dengue NS1},
  journal = {Biosensors and Bioelectronics},
  year = {2027},
  volume = {317},
  pages = {119362},
  doi = {10.1016/j.bios.2026.119362}
}
Kostenlos starten →