Decoupling neurodegenerative protein signals in biofluids via cross-reactive interfaces and inverted multi-dynamic encoders
Biosensors and Bioelectronics · 2027-01 · 316 · 119356
DOI: 10.1016/j.bios.2026.119356 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2027-01. Verfasst von Yun Ji Hwang und 9 weiteren Autor:innen. Beteiligte Einrichtung: School of Mechanical Engineering, Yonsei University, 50, Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea. Hauptthemen laut MEDLINE: Biosensing Techniques, alpha-Synuclein, Amyloid beta-Peptides, tau Proteins. Die Arbeit nennt 43 Literaturangaben. Gefördert von: Korea Ministry of Environment, Korea Ministry of Science and ICT, MOTIE.
Abstract (Originalsprache)
The direct analysis of neurodegenerative proteins in complex biofluids is inherently limited by severe Debye screening and non-specific protein interference, often necessitating extensive sample dilution in conventional assays. Traditional target-specific sensors fail to extract reliable signals from these physiological matrices. Here, we present a hardware-software co-design integrating a cross-reactive tiered deoxygenation graphene oxide (TDGO) sensor with an inverted multi-dynamic encoder (IMDE) framework to simultaneously quantify multiplexed targets (Aβ42, tau-441, and α-synuclein). To overcome matrix complexity, the physical interface operates under a dual-stress condition, combining inherent matrix interference with dynamic electrochemical modulation (stepped back-gate voltage, VBG = 0-20 V). This approach generates high-dimensional orthogonal data from non-linear sensor outputs, achieving a physical limit of detection below 0.1 pg/mL. By dynamically mapping these physical variations, the IMDE mathematically inverts the signal entanglement to achieve precise target quantification (R2 = 0.914) directly in protein-fortified human serum. As a proof-of-concept for clinical application, we couple the IMDE with a multi-layer perceptron downstream classifier, successfully discriminating multi-class disease states in neat transgenic mouse plasma (AUROC = 0.917). Complemented by SHAP analysis to ensure signal interpretability, this platform provides a highly transferable bioelectronic methodology for decoding non-linear physiological signals.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Mechanical Engineering, Yonsei University, 50, Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea.
- Graduate School of Medicine, Yonsei University, Seoul, 03722, Republic of Korea.
- Department of Psychiatry, Laboratory for Alzheimer's Molecular Psychiatry, Institute of Behavioral Science in Medicine, Yonsei University College of Medicine, Seoul, 03722, Republic of Korea; Metabolism-Dementia Researc…
- Center for BioMicrosystems, Brain Science Institute, Korea Institute of Science and Technology (KIST), Seoul, 02792, Republic of Korea. Electronic address: shleekist@kist.re.kr.
- Graduate School of Medicine, Yonsei University, Seoul, 03722, Republic of Korea; Department of Psychiatry, Laboratory for Alzheimer's Molecular Psychiatry, Institute of Behavioral Science in Medicine, Yonsei University…
- School of Mechanical Engineering, Yonsei University, 50, Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea; Department of Battery Engineering, Yonsei University, Seoul, 03722, Republic of Korea. Electronic addres…
Förderung
- Korea Ministry of Environment
- Korea Ministry of Science and ICT
- MOTIE
- National Research Foundation of Korea
- KIST
- Korea Ministry of Health and Welfare
Zitieren
APA
Hwang, Y. J., Hwang, T., Song, D., Dong, H., Liu, T., Cha, H. G., Kim, H., Lee, S. H., Kim, E., & Jun, S. C. (2027). Decoupling neurodegenerative protein signals in biofluids via cross-reactive interfaces and inverted multi-dynamic encoders. Biosensors and Bioelectronics, 316, 119356. https://doi.org/10.1016/j.bios.2026.119356
Vancouver
Hwang YJ, Hwang T, Song D, Dong H, Liu T, Cha HG, et al. Decoupling neurodegenerative protein signals in biofluids via cross-reactive interfaces and inverted multi-dynamic encoders. Biosensors and Bioelectronics. 2027;316:119356. doi:10.1016/j.bios.2026.119356
BibTeX
@article{Hwang2027,
author = {Hwang, Yun Ji and Hwang, Teajong and Song, Dabin and Dong, Hang and Liu, Tianci and Cha, Hye Gyu and Kim, Hyunjeong and Lee, Soo Hyun and Kim, Eosu and Jun, Seong Chan},
title = {Decoupling neurodegenerative protein signals in biofluids via cross-reactive interfaces and inverted multi-dynamic encoders},
journal = {Biosensors and Bioelectronics},
year = {2027},
volume = {316},
pages = {119356},
doi = {10.1016/j.bios.2026.119356}
}
EUVIMED