EUVIMEDEUVIMED entdecken
Crossref

Decoupling neurodegenerative protein signals in biofluids via cross-reactive interfaces and inverted multi-dynamic encoders

Yun Ji Hwang, Teajong Hwang, Dabin Song, Hang Dong, Tianci Liu, Hye Gyu Cha, Hyunjeong Kim, Soo Hyun Lee, Eosu Kim, Seong Chan Jun

Biosensors and Bioelectronics · 2027-01 · 316 · 119356

DOI: 10.1016/j.bios.2026.119356 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2027-01. Verfasst von Yun Ji Hwang und 9 weiteren Autor:innen. Beteiligte Einrichtung: School of Mechanical Engineering, Yonsei University, 50, Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea. Hauptthemen laut MEDLINE: Biosensing Techniques, alpha-Synuclein, Amyloid beta-Peptides, tau Proteins. Die Arbeit nennt 43 Literaturangaben. Gefördert von: Korea Ministry of Environment, Korea Ministry of Science and ICT, MOTIE.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The direct analysis of neurodegenerative proteins in complex biofluids is inherently limited by severe Debye screening and non-specific protein interference, often necessitating extensive sample dilution in conventional assays. Traditional target-specific sensors fail to extract reliable signals from these physiological matrices. Here, we present a hardware-software co-design integrating a cross-reactive tiered deoxygenation graphene oxide (TDGO) sensor with an inverted multi-dynamic encoder (IMDE) framework to simultaneously quantify multiplexed targets (Aβ42, tau-441, and α-synuclein). To overcome matrix complexity, the physical interface operates under a dual-stress condition, combining inherent matrix interference with dynamic electrochemical modulation (stepped back-gate voltage, VBG = 0-20 V). This approach generates high-dimensional orthogonal data from non-linear sensor outputs, achieving a physical limit of detection below 0.1 pg/mL. By dynamically mapping these physical variations, the IMDE mathematically inverts the signal entanglement to achieve precise target quantification (R2 = 0.914) directly in protein-fortified human serum. As a proof-of-concept for clinical application, we couple the IMDE with a multi-layer perceptron downstream classifier, successfully discriminating multi-class disease states in neat transgenic mouse plasma (AUROC = 0.917). Complemented by SHAP analysis to ensure signal interpretability, this platform provides a highly transferable bioelectronic methodology for decoding non-linear physiological signals.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing Techniquesalpha-SynucleinAmyloid beta-Peptidestau ProteinsPeptide FragmentsGraphiteHumansLimit of DetectionAnimalsEquipment Design

Stichwörter der Autor:innen

Dual-stress environmentDynamic loss weightsInverted multi-dynamic encoderNeurodegenerative proteinsSignal decouplingTiered deoxygenation graphene oxide

Substanzen

Graphitegraphene oxidealpha-SynucleinAmyloid beta-Peptidestau ProteinsPeptide Fragmentsamyloid beta-protein (1-42)

Autor:innen und Institutionen

  • School of Mechanical Engineering, Yonsei University, 50, Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea.
  • Graduate School of Medicine, Yonsei University, Seoul, 03722, Republic of Korea.
  • Department of Psychiatry, Laboratory for Alzheimer's Molecular Psychiatry, Institute of Behavioral Science in Medicine, Yonsei University College of Medicine, Seoul, 03722, Republic of Korea; Metabolism-Dementia Researc…
  • Center for BioMicrosystems, Brain Science Institute, Korea Institute of Science and Technology (KIST), Seoul, 02792, Republic of Korea. Electronic address: shleekist@kist.re.kr.
  • Graduate School of Medicine, Yonsei University, Seoul, 03722, Republic of Korea; Department of Psychiatry, Laboratory for Alzheimer's Molecular Psychiatry, Institute of Behavioral Science in Medicine, Yonsei University…
  • School of Mechanical Engineering, Yonsei University, 50, Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea; Department of Battery Engineering, Yonsei University, Seoul, 03722, Republic of Korea. Electronic addres…

Förderung

  • Korea Ministry of Environment
  • Korea Ministry of Science and ICT
  • MOTIE
  • National Research Foundation of Korea
  • KIST
  • Korea Ministry of Health and Welfare

Zitieren

APA

Hwang, Y. J., Hwang, T., Song, D., Dong, H., Liu, T., Cha, H. G., Kim, H., Lee, S. H., Kim, E., & Jun, S. C. (2027). Decoupling neurodegenerative protein signals in biofluids via cross-reactive interfaces and inverted multi-dynamic encoders. Biosensors and Bioelectronics, 316, 119356. https://doi.org/10.1016/j.bios.2026.119356

Vancouver

Hwang YJ, Hwang T, Song D, Dong H, Liu T, Cha HG, et al. Decoupling neurodegenerative protein signals in biofluids via cross-reactive interfaces and inverted multi-dynamic encoders. Biosensors and Bioelectronics. 2027;316:119356. doi:10.1016/j.bios.2026.119356

BibTeX
@article{Hwang2027,
  author = {Hwang, Yun Ji and Hwang, Teajong and Song, Dabin and Dong, Hang and Liu, Tianci and Cha, Hye Gyu and Kim, Hyunjeong and Lee, Soo Hyun and Kim, Eosu and Jun, Seong Chan},
  title = {Decoupling neurodegenerative protein signals in biofluids via cross-reactive interfaces and inverted multi-dynamic encoders},
  journal = {Biosensors and Bioelectronics},
  year = {2027},
  volume = {316},
  pages = {119356},
  doi = {10.1016/j.bios.2026.119356}
}
Kostenlos starten →