EUVIMEDEUVIMED entdecken
Crossref

Machine learning-empowered nanobody-based dual-mode immunosensor using gold-silver nanoclusters for the accurate detection of Shigella flexneri in food

Xueyi Fan, Kai Zheng, Mengnan Wang, Guangsheng Ge, Yuxin Miao, Qing Yao, Pengyu Chen, Min Ma, Jianlong Wang, Yanru Wang

Biosensors and Bioelectronics · 2027-01 · 316 · 119352

DOI: 10.1016/j.bios.2026.119352 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2027-01. Verfasst von Xueyi Fan und 9 weiteren Autor:innen. Beteiligte Einrichtung: College of Food Science and Engineering, Northwest A&F University, Yangling, Shaanxi, 712100, China. Hauptthemen laut MEDLINE: Shigella flexneri, Biosensing Techniques, Dysentery, Bacillary. Die Arbeit nennt 46 Literaturangaben. Gefördert von: Shaanxi Province Key Research and Development Projects, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Sensitive and rapid detection of Shigella flexneri (S. flexneri) is of great significance for food safety and public health. In this study, a nanobody-based colorimetric/fluorescent dual-mode immunosensor was developed for the first time, and a machine learning model was integrated for intelligent fusion of the dual signals. A phage-displayed nanobody library was constructed by immunizing Bactrian camels with formalin-inactivated S. flexneri and specific nanobodies were obtained after four rounds of solid-phase panning. Using bovine serum albumin-protected gold-silver bimetallic nanoclusters (Au-Ag NCs) as fluorescent probes, a dual-signal output platform was established. Under optimized conditions, the colorimetric mode achieved a limit of detection (LOD) of 2.992 × 104 CFU/mL, and exhibited no cross-reactivity with other common foodborne pathogens. The LOD in the fluorescent mode was as low as 4.074 × 103 CFU/mL, which is 7.3 times lower than that of the colorimetric mode. A machine learning model combining K-Nearest Neighbors classification and Random Forest regression was employed for intelligent calibration of the dual signals, significantly improving the reliability and stability of the assay. With the assistance of the machine learning model, the coefficient of determination (R2) between predicted and actual concentrations reached 0.9953. Spike-and-recovery experiments in food samples yielded recovery rates ranging from 81.53% to 109.46%, demonstrating high accuracy. This study provides a novel, rapid, accurate, and environmentally friendly strategy for the detection of S. flexneri, holding great promise for applications in food safety monitoring.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Shigella flexneriBiosensing TechniquesDysentery, BacillaryMachine LearningSilverGoldMetal NanoparticlesAnimalsSingle-Domain AntibodiesLimit of DetectionImmunoassayCamelusColorimetryFood Microbiology

Stichwörter der Autor:innen

Dual-mode immunosensorGold-silver bimetallic nanoclustersMachine learningNanobodyShigella flexneri

Substanzen

SilverGoldSingle-Domain Antibodies

Autor:innen und Institutionen

  • College of Food Science and Engineering, Northwest A&F University, Yangling, Shaanxi, 712100, China.
  • College of Food Science and Engineering, Northwest A&F University, Yangling, Shaanxi, 712100, China. Electronic address: yanruwang22@163.com.

Förderung

  • Shaanxi Province Key Research and Development Projects
  • National Natural Science Foundation of China

Zitieren

APA

Fan, X., Zheng, K., Wang, M., Ge, G., Miao, Y., Yao, Q., Chen, P., Ma, M., Wang, J., & Wang, Y. (2027). Machine learning-empowered nanobody-based dual-mode immunosensor using gold-silver nanoclusters for the accurate detection of Shigella flexneri in food. Biosensors and Bioelectronics, 316, 119352. https://doi.org/10.1016/j.bios.2026.119352

Vancouver

Fan X, Zheng K, Wang M, Ge G, Miao Y, Yao Q, et al. Machine learning-empowered nanobody-based dual-mode immunosensor using gold-silver nanoclusters for the accurate detection of Shigella flexneri in food. Biosensors and Bioelectronics. 2027;316:119352. doi:10.1016/j.bios.2026.119352

BibTeX
@article{Fan2027,
  author = {Fan, Xueyi and Zheng, Kai and Wang, Mengnan and Ge, Guangsheng and Miao, Yuxin and Yao, Qing and Chen, Pengyu and Ma, Min and Wang, Jianlong and Wang, Yanru},
  title = {Machine learning-empowered nanobody-based dual-mode immunosensor using gold-silver nanoclusters for the accurate detection of Shigella flexneri in food},
  journal = {Biosensors and Bioelectronics},
  year = {2027},
  volume = {316},
  pages = {119352},
  doi = {10.1016/j.bios.2026.119352}
}
Kostenlos starten →