EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

PHB/ErGO electrochemical immunosensor for H5N1 serology: Insights into selectivity and inflammation-mediated matrix effects

Gustavo Martins, Mauricio A P Papi, Breno C B Beirão, Márcio F Bergamini, Luiz Humberto Marcolino-Junior

Biosensors and Bioelectronics · 2027-01 · 316 · 119339

DOI: 10.1016/j.bios.2026.119339 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2027-01. Verfasst von Gustavo Martins und 4 weiteren Autor:innen. Beteiligte Einrichtung: Laboratório de Sensores Eletroquímicos (LabSensE), Departamento de Química, Universidade Federal do Paraná (UFPR), CEP 81.531-980, Curitiba, PR, Braz…. Hauptthemen laut MEDLINE: Graphite, Biosensing Techniques, Influenza A Virus, H5N1 Subtype, Antibodies, Viral. Die Arbeit nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Council for Scientific and Technological Development, Coordenação de Aperfeiçoamento de Pessoal de Nível Superior, Financiadora de Estudos e Projetos.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Reliable electrochemical immunosensing in biological samples requires not only selective molecular recognition but also preservation of analytical performance in complex matrices. Here, a label-free electrochemical immunosensor based on electrochemically reduced graphene oxide (ErGO) and polyhydroxybutyrate (PHB) nanoparticles was developed for the detection of anti-H5N1 antibodies in chicken serum. PHB nanoparticles were pre-functionalized with H5N1 hemagglutinin and deposited onto disposable ErGO-modified screen-printed electrodes, providing a simplified strategy for biointerface assembly. Structural, morphological, and electrochemical characterization confirmed the formation of the sensing interface and its response to antibody binding. The immunosensor exhibited a linear response from 1 pg mL-1 to 10 ng mL-1, with a detection limit of 1 pg mL-1, and showed selective recognition of anti-H5N1 antibodies in the presence of unrelated viral antibodies and proteins. Systematic comparison of PBS, healthy serum, and inflammatory serum revealed a progressive reduction in analytical sensitivity, with calibration slopes of 5.53, 3.03, and 1.69, respectively, accompanied by increased baseline suppression. Nevertheless, concentration-dependent responses and target discrimination were maintained in serum matrices. These findings support the use of the ErGO/PHB interface for anti-H5N1 detection and quantify the loss of analytical sensitivity observed in the serum conditions investigated.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

GraphiteBiosensing TechniquesInfluenza A Virus, H5N1 SubtypeAntibodies, ViralInfluenza in BirdsAnimalsElectrochemical TechniquesImmunoassayLimit of DetectionChickensProhibitinsHydroxybutyratesPolyhydroxybutyratesNanoparticlesPolyestersHumans

Stichwörter der Autor:innen

Electrochemical immunosensorInflammationPolyhydroxybutyrateSerum matrix effectsanti-H5N1

Substanzen

Graphitegraphene oxideAntibodies, ViralProhibitinsHydroxybutyratesPolyhydroxybutyratesPolyesterspoly-beta-hydroxybutyratePHB protein, human

Autor:innen und Institutionen

  • Laboratório de Sensores Eletroquímicos (LabSensE), Departamento de Química, Universidade Federal do Paraná (UFPR), CEP 81.531-980, Curitiba, PR, Brazil.
  • Graduate Program in Microbiology, Parasitology, and Pathology, Federal University of Paraná (UFPR), CEP 81531-980, Curitiba, PR, Brazil.
  • Laboratório de Sensores Eletroquímicos (LabSensE), Departamento de Química, Universidade Federal do Paraná (UFPR), CEP 81.531-980, Curitiba, PR, Brazil. Electronic address: bergamini@ufpr.br.
  • Laboratório de Sensores Eletroquímicos (LabSensE), Departamento de Química, Universidade Federal do Paraná (UFPR), CEP 81.531-980, Curitiba, PR, Brazil. Electronic address: luiz1berto@ufpr.br.

Förderung

  • National Council for Scientific and Technological Development
  • Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
  • Financiadora de Estudos e Projetos
  • Fundação Araucária
  • Instituto de Ciência e Tecnologia de Nanomateriais de Carbono

Zitieren

APA

Martins, G., Papi, M. A. P., Beirão, B. C. B., Bergamini, M. F., & Marcolino-Junior, L. H. (2027). PHB/ErGO electrochemical immunosensor for H5N1 serology: Insights into selectivity and inflammation-mediated matrix effects. Biosensors and Bioelectronics, 316, 119339. https://doi.org/10.1016/j.bios.2026.119339

Vancouver

Martins G, Papi MAP, Beirão BCB, Bergamini MF, Marcolino-Junior LH. PHB/ErGO electrochemical immunosensor for H5N1 serology: Insights into selectivity and inflammation-mediated matrix effects. Biosensors and Bioelectronics. 2027;316:119339. doi:10.1016/j.bios.2026.119339

BibTeX
@article{Martins2027,
  author = {Martins, Gustavo and Papi, Mauricio A P and Beirão, Breno C B and Bergamini, Márcio F and Marcolino-Junior, Luiz Humberto},
  title = {PHB/ErGO electrochemical immunosensor for H5N1 serology: Insights into selectivity and inflammation-mediated matrix effects},
  journal = {Biosensors and Bioelectronics},
  year = {2027},
  volume = {316},
  pages = {119339},
  doi = {10.1016/j.bios.2026.119339}
}
Kostenlos starten →