Two-dimensionally expanded flow cytometry with an array of time-gated single photon avalanche diodes
Biosensors and Bioelectronics · 2027
DOI: 10.1016/j.bios.2026.119290 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2027. Verfasst von Kunihiko Iizuka und 4 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Industrial Science, The University of Tokyo, Tokyo, Japan; Lab Arco Limited, Osaka, Japan. Hauptthemen laut MEDLINE: Flow Cytometry, Biosensing Techniques. Die Arbeit nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Japan Society for the Promotion of Science, Precursory Research for Embryonic Science and Technology.
Abstract (Originalsprache)
Conventional flow cytometry typically relies on narrow fluidic channels and optical filters, which can limit the handling of varied sample types and increase system complexity. Here we present two-dimensionally expanded flow cytometry (2DFC) employing an array of time-gated single-photon avalanche diodes (SPADs) to enable parallelized, high-throughput fluorescence detection of single cells and cell clusters of various sizes. In 2DFC, individual time-gated SPADs serve as interrogation points of the flow cytometer, enabling two-dimensional expansion of the interrogation area through an array of SPADs integrated into the bottom surface of a wide microfluidic channel. By temporally gating the SPADs following pulsed laser excitation, fluorescence signals are separated from excitation light in the time domain, enabling direct detection of fluorescence from cells flowing over the SPAD array without the need for optical filters. Leveraging the scalable architecture of the time-gated SPAD array, 2DFC successfully detects both individual cells and multicellular clusters. By tuning the accumulation count for SPAD detection, 2DFC successfully resolves cellular fluorescence signals at a cell concentration of 1 × 106 cells/mL and a volumetric flow rate of up to 1 mL/min without fluidic focusing mechanisms. These results demonstrate the potential of 2DFC as a scalable platform for high-throughput analysis of heterogeneous cell suspensions in biomedical research and clinical diagnosis.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Institute of Industrial Science, The University of Tokyo, Tokyo, Japan; Lab Arco Limited, Osaka, Japan.
- Institute of Industrial Science, The University of Tokyo, Tokyo, Japan.
- Institute of Industrial Science, The University of Tokyo, Tokyo, Japan. Electronic address: shkim@iis.u-tokyo.ac.jp.
Förderung
- Japan Society for the Promotion of Science
- Precursory Research for Embryonic Science and Technology
Zitieren
APA
Iizuka, K., Mikami, S., Tago, S., Fujii, T., & Kim, S. H. (2027). Two-dimensionally expanded flow cytometry with an array of time-gated single photon avalanche diodes. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2026.119290
Vancouver
Iizuka K, Mikami S, Tago S, Fujii T, Kim SH. Two-dimensionally expanded flow cytometry with an array of time-gated single photon avalanche diodes. Biosensors and Bioelectronics. 2027. doi:10.1016/j.bios.2026.119290
BibTeX
@article{Iizuka2027,
author = {Iizuka, Kunihiko and Mikami, Shogo and Tago, Saori and Fujii, Teruo and Kim, Soo Hyeon},
title = {Two-dimensionally expanded flow cytometry with an array of time-gated single photon avalanche diodes},
journal = {Biosensors and Bioelectronics},
year = {2027},
doi = {10.1016/j.bios.2026.119290}
}
EUVIMED