EUVIMEDEUVIMED entdecken
Crossref

Oxygen vacancies-induced dual-interface modulation for TiO2/BiOI-based photoelectrochemical biosensor of urinary cancer markers

Yanmei Xin, Yuanyuan Zhang, Ruiting Zhang, Haizi Yao, Zhenglin Zhang, Huichuan Yu, Xianwei Yang, Zhuo Wang, Yuqing Miao, Hui Lin, Zhonghai Zhang, Dan Wu

Biosensors and Bioelectronics · 2026

DOI: 10.1016/j.bios.2026.119172 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2026. Verfasst von Yanmei Xin und 11 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Bismuth Science, School of Materials and Chemistry, University of Shanghai for Science and Technology, 334 Jungong Road, Shanghai, 20009…. Hauptthemen laut MEDLINE: Titanium, Biosensing Techniques, Biomarkers, Tumor, alpha-Fetoproteins. Die Arbeit nennt 42 Literaturangaben. Gefördert von: Natural Science Foundation of Henan Province, National Natural Science Foundation of China, Shanghai Key Laboratory of Molecular Imaging.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Non-invasive urine-based cancer biomarker detection holds significant clinical value in cancer screening, treatment efficacy monitoring, recurrence warning, and auxiliary diagnosis. To address the issues of poor sensitivity and selectivity in photoelectrochemical (PEC) biosensing for the detection of cancer biomarkers in urine, oxygen vacancies (OVs)-induced dual-interface modulation strategy is proposed for constructing a TiO2/BiOI-based PEC sensor. The introduction of OVs not only induces the in-situ formation of bismuth nanoparticles at the solid-solid interface but also generates positive surface charge at the solid-liquid interface, which promotes the formation of the Z-scheme heterojunction and the modification with a negatively charged anti-fouling polymer layer (C-PEG), thereby effectively enhancing the photoelectric conversion efficiency and antifouling performance of the PEC sensor. Meanwhile, functionalization with aptamers further improves its selectivity. Leveraging the synergistic effects of the Z-scheme, anti-fouling polymer layers, and aptamers, the developed PEC sensor achieves highly sensitive and selective detection of alpha-fetoprotein (AFP), with a linear relationship in the range of 1.0 pg/mL∼150.0 ng/mL, and a detection limit of 0.3 pg/mL (LOD = 3s/k). In addition, the sensor successfully measures AFP levels in serum and urine samples from healthy individuals and hepatocellular carcinoma patients, and statistical analysis reveals a strong correlation between the serum and urinary AFP concentrations (r = 0.934, P < 0.001, n = 9). These findings indicate the preliminary feasibility of the proposed PEC sensor for non-invasive urine-based AFP detection, which may provide insights for future research.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TitaniumBiosensing TechniquesBiomarkers, Tumoralpha-FetoproteinsHumansElectrochemical TechniquesOxygenBismuthLimit of DetectionAptamers, Nucleotide

Stichwörter der Autor:innen

AFPDual-interface engineeringOxygen vacanciesPhotoelectrochemical sensingUrine

Substanzen

TitaniumBiomarkers, Tumortitanium dioxidealpha-FetoproteinsOxygenBismuthAptamers, Nucleotide

Autor:innen und Institutionen

  • Institute of Bismuth Science, School of Materials and Chemistry, University of Shanghai for Science and Technology, 334 Jungong Road, Shanghai, 200093, China.
  • School of Energy Engineering, Huanghuai University, Zhumadian, Henan, 463600, China.
  • Gastroenterology Department, Shanghai Jing'an District Zhabei Central Hospital, Shanghai, 200072, China. Electronic address: niliuh@163.com.
  • School of Chemistry and Molecular Engineering, East China Normal University, 500 Dongchuan Road, Shanghai, 200241, China. Electronic address: zhzhang@chem.ecnu.edu.cn.
  • Shanghai Key Laboratory of Molecular Imaging, Shanghai University of Medicine and Health Sciences, Shanghai, 201318, China. Electronic address: wud_21@sumhs.edu.cn.

Förderung

  • Natural Science Foundation of Henan Province
  • National Natural Science Foundation of China
  • Shanghai Key Laboratory of Molecular Imaging

Zitieren

APA

Xin, Y., Zhang, Y., Zhang, R., Yao, H., Zhang, Z., Yu, H., Yang, X., Wang, Z., Miao, Y., Lin, H., Zhang, Z., & Wu, D. (2026). Oxygen vacancies-induced dual-interface modulation for TiO2/BiOI-based photoelectrochemical biosensor of urinary cancer markers. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2026.119172

Vancouver

Xin Y, Zhang Y, Zhang R, Yao H, Zhang Z, Yu H, et al. Oxygen vacancies-induced dual-interface modulation for TiO2/BiOI-based photoelectrochemical biosensor of urinary cancer markers. Biosensors and Bioelectronics. 2026. doi:10.1016/j.bios.2026.119172

BibTeX
@article{Xin2026,
  author = {Xin, Yanmei and Zhang, Yuanyuan and Zhang, Ruiting and Yao, Haizi and Zhang, Zhenglin and Yu, Huichuan and Yang, Xianwei and Wang, Zhuo and Miao, Yuqing and Lin, Hui and Zhang, Zhonghai and Wu, Dan},
  title = {Oxygen vacancies-induced dual-interface modulation for TiO2/BiOI-based photoelectrochemical biosensor of urinary cancer markers},
  journal = {Biosensors and Bioelectronics},
  year = {2026},
  doi = {10.1016/j.bios.2026.119172}
}
Kostenlos starten →