EUVIMEDEUVIMED entdecken
Crossref

Photo-driven gated dual-mode aptasensor based on CQDs@PCN-224@ZIF-8 and Exo I–HCR cascade amplification for ultrasensitive bisphenol A detection

Weisheng Xue, Baoshan He, Xiaoyu Cao, Lingling Xie, Yao Liu, Wenhong Zhao, Wenjie Ren, Yiwei Xu

Biosensors and Bioelectronics · 2026

DOI: 10.1016/j.bios.2026.119115 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2026. Verfasst von Weisheng Xue und 7 weiteren Autor:innen. Beteiligte Einrichtung: School of Food Science and Technology, Henan University of Technology, Zhengzhou, Henan, 450001, PR China. Hauptthemen laut MEDLINE: Benzhydryl Compounds, Phenols, Biosensing Techniques, Aptamers, Nucleotide. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 46 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Henan University of Technology, Natural Science Foundation of Henan Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Dual-mode biosensors offer an effective strategy for reducing signal ambiguity and improving the reliability of trace small-molecule detection. However, integrating photo-driven transduction, fluorescence modulation, and nucleic acid cascade amplification into a single sensing system remains challenging. Herein, a photo-driven fluorometric/colorimetric dual-mode aptasensor was developed for ultrasensitive bisphenol A (BPA) detection by coupling a CQDs@PCN-224@ZIF-8 nanoplatform with Exonuclease I (Exo I)-mediated target recycling and hybridization chain reaction (HCR) amplification. The CQDs@PCN-224@ZIF-8 interface enabled fluorescence quenching of FAM-labeled probes and visible-light-driven TMB oxidation, while the Exo I-HCR cascade converted BPA recognition into amplified optical responses. The proposed aptasensor achieved detection limits of 0.76 pM and 3.47 pM for the fluorometric and colorimetric modes, respectively. The dual-output readout provided mutually supportive signal validation, improving the reliability of BPA detection. The aptasensor showed satisfactory selectivity, stability, and reproducibility, and was applied to BPA-spiked milk, bottled water, and canned yellow peach samples with acceptable recovery results, which were consistent with those obtained using the LC-MS/MS-based national standard method. Furthermore, smartphone-assisted RGB readout enabled visual quantification, highlighting the potential of the proposed platform for on-site BPA monitoring in food safety applications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Benzhydryl CompoundsPhenolsBiosensing TechniquesAptamers, NucleotideBisphenol A CompoundsLimit of DetectionExodeoxyribonucleasesColorimetryAnimalsMilkImidazolesMetal-Organic Frameworks

Stichwörter der Autor:innen

Bisphenol ACQDs@PCN-224@ZIF-8Dual-mode aptasensorExo I–HCRPhotocatalysis

Substanzen

Benzhydryl CompoundsBisphenol A Compoundsbisphenol APhenolsAptamers, Nucleotideexodeoxyribonuclease IExodeoxyribonucleasesZIF-8 metal-organic frameworkImidazolesMetal-Organic Frameworks

Autor:innen und Institutionen

  • School of Food Science and Technology, Henan University of Technology, Zhengzhou, Henan, 450001, PR China.
  • School of Food Science and Technology, Henan University of Technology, Zhengzhou, Henan, 450001, PR China. Electronic address: hebaoshan@126.com.
  • School of Chemistry and Chemical Engineering, Henan University of Technology, Zhengzhou, Henan, 450001, PR China.
  • School of Environmental Engineering, Henan University of Technology, Zhengzhou, Henan, 450001, PR China.
  • Henan Scientific Research Platform Service Center, Zhengzhou, Henan, 450003, PR China.

Förderung

  • National Natural Science Foundation of China
  • Henan University of Technology
  • Natural Science Foundation of Henan Province

Zitieren

APA

Xue, W., He, B., Cao, X., Xie, L., Liu, Y., Zhao, W., Ren, W., & Xu, Y. (2026). Photo-driven gated dual-mode aptasensor based on CQDs@PCN-224@ZIF-8 and Exo I–HCR cascade amplification for ultrasensitive bisphenol A detection. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2026.119115

Vancouver

Xue W, He B, Cao X, Xie L, Liu Y, Zhao W, et al. Photo-driven gated dual-mode aptasensor based on CQDs@PCN-224@ZIF-8 and Exo I–HCR cascade amplification for ultrasensitive bisphenol A detection. Biosensors and Bioelectronics. 2026. doi:10.1016/j.bios.2026.119115

BibTeX
@article{Xue2026,
  author = {Xue, Weisheng and He, Baoshan and Cao, Xiaoyu and Xie, Lingling and Liu, Yao and Zhao, Wenhong and Ren, Wenjie and Xu, Yiwei},
  title = {Photo-driven gated dual-mode aptasensor based on CQDs@PCN-224@ZIF-8 and Exo I–HCR cascade amplification for ultrasensitive bisphenol A detection},
  journal = {Biosensors and Bioelectronics},
  year = {2026},
  doi = {10.1016/j.bios.2026.119115}
}
Kostenlos starten →