EUVIMEDEUVIMED entdecken
Crossref

Highly responsive signal-on biosensor based on autocatalytic and antifouling cell membrane gel interface for ultrasensitive immunoassay

Zhengjun Dong, Liangyu Chen, Lu Zhao, Xianzhen Song, Caifeng Ding

Biosensors and Bioelectronics · 2026

DOI: 10.1016/j.bios.2026.119110 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2026. Verfasst von Zhengjun Dong und 4 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, Ministry of Education, Shandong Key Laboratory of Biochemical Ana…. Hauptthemen laut MEDLINE: Biosensing Techniques, Cell Membrane, Serpins. Die Arbeit nennt 39 Literaturangaben. Gefördert von: Taishan Scholar Foundation of Shandong Province, Qingdao Postdoctoral Science Foundation, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In sensing analysis, controlling signal switch through targets is a key method to ensure detection sensitivity. To improve the control effect, an antifouling sensor based on controlled-release and co-reaction catalytic strategies was designed. Concretely, the gel interface with the biocompatible red cell membrane as the skeleton was developed to resist the non-specific adsorption of interfering proteins in the serum environment. Secondly, due to the strong specific binding of antigens and antibodies, S QDs were released from the cavity of mesoporous SiO2, thereby achieving target-induced signal self-on. At the same time, Pd NCs encapsulated in the antifouling hydrogel were used for autocatalysis of luminescence signals to achieve highly responsive signal-on. The integration of interface antifouling and controlled release effectively avoided the adverse interferences from external environment and background signals, improving the reliability of target-induced responses, and the highly responsive signal-on mode endowed the biosensor with high sensitivity. Based on this, the constructed biosensor realized trace detection of squamous cell carcinoma antigen in a wide detection range of 100 fg/mL ∼1 μg/mL, with a detection limit of 27.7 fg/mL, meeting the needs of early clinical diagnosis of related cancers. The proposed biosensing platform based on cell membrane antifouling and highly responsive signal-on provides a powerful tool for the applications in clinical diagnose and other biological detection scenarios.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesCell MembraneSerpinsImmunoassaySilicon DioxideHumansLimit of DetectionQuantum DotsBiofoulingCatalysis

Stichwörter der Autor:innen

AutocatalysisCell membraneControlled releaseInterface antifoulingSignal self-on

Substanzen

Silicon DioxideSerpins

Autor:innen und Institutionen

  • Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, Ministry of Education, Shandong Key Laboratory of Biochemical Analysis, Key Laboratory of Analytical Chemistry for Life Science in Univ…

Förderung

  • Taishan Scholar Foundation of Shandong Province
  • Qingdao Postdoctoral Science Foundation
  • National Natural Science Foundation of China
  • Shandong Province Natural Science Foundation

Zitieren

APA

Dong, Z., Chen, L., Zhao, L., Song, X., & Ding, C. (2026). Highly responsive signal-on biosensor based on autocatalytic and antifouling cell membrane gel interface for ultrasensitive immunoassay. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2026.119110

Vancouver

Dong Z, Chen L, Zhao L, Song X, Ding C. Highly responsive signal-on biosensor based on autocatalytic and antifouling cell membrane gel interface for ultrasensitive immunoassay. Biosensors and Bioelectronics. 2026. doi:10.1016/j.bios.2026.119110

BibTeX
@article{Dong2026,
  author = {Dong, Zhengjun and Chen, Liangyu and Zhao, Lu and Song, Xianzhen and Ding, Caifeng},
  title = {Highly responsive signal-on biosensor based on autocatalytic and antifouling cell membrane gel interface for ultrasensitive immunoassay},
  journal = {Biosensors and Bioelectronics},
  year = {2026},
  doi = {10.1016/j.bios.2026.119110}
}
Kostenlos starten →