Learning-assisted transient-response analysis of nitride high-electron-mobility transistor aptasensors for rapid carcinoembryonic antigen detection
Biosensors and Bioelectronics · 2026-11 · 312 · 119045
DOI: 10.1016/j.bios.2026.119045 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2026-11. Verfasst von Jian Tang und 3 weiteren Autor:innen. Beteiligte Einrichtung: College of Physics and Electronic Engineering, Yancheng Teachers University, Yancheng, 224007, China. Electronic address: tangj01@yctu.edu.cn. Hauptthemen laut MEDLINE: Biosensing Techniques, Carcinoembryonic Antigen, Aptamers, Nucleotide. Die Arbeit nennt 44 Literaturangaben. Gefördert von: National Natural Science Foundation of China.
Themen: Mobilisation
Abstract (Originalsprache)
Carcinoembryonic antigen (CEA) is widely used for tumor monitoring, yet electrical biosensor readouts are commonly based on endpoint or steady-state signals and therefore discard information contained in the early transient response. We developed a learning-assisted readout for an existing AlGaN/GaN high-electron-mobility transistor (HEMT) aptasensor by integrating transient drain-source current sequences with four steady-state I-V descriptors in a bidirectional long short-term memory-multilayer perceptron (LSTM-MLP) model. Bias-voltage comparison identified V_DS = 0.5 V as the preferred operating point on the basis of response amplitude, noise, and signal-to-noise ratio. Eighteen independent response curves spanning six experimentally tested CEA concentrations were evaluated by grouped three-fold cross-validation at the original-curve level, yielding R2 = 0.998, RMSE(log10) = 0.078, and MAE(log10) = 0.062. Curve-level low-concentration measurements analyzed with a fixed decision threshold and logistic detection-probability model produced a model-assisted C95 of 3.20 pg/mL (95% bootstrap confidence interval: 2.83-3.52 pg/mL). Sequence-length analysis showed that 120 s was the earliest interval meeting prespecified performance-retention criteria relative to the complete 1000 s record. In 1:10 diluted pooled human serum, baseline-corrected recoveries were 97.6%, 98.0%, and 95.0% at 5, 500, and 50,000 pg/mL, respectively; comparison with 1:20 serum further demonstrated dilution-dependent matrix effects. These findings show that transient-response learning can extract quantitative information not fully used by steady-state analysis, while broader device-batch and clinical validation remains necessary.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- College of Physics and Electronic Engineering, Yancheng Teachers University, Yancheng, 224007, China. Electronic address: tangj01@yctu.edu.cn.
- Department of Electrical Engineering, City University of Hong Kong, Hong Kong, 999077, China.
- State Key Laboratory of Optoelectronic Materials and Devices, Institute of Semiconductors, Chinese Academy of Sciences, Beijing, 100083, China; College of Materials Science and Opto-Electronic Technology, University of…
- Laboratory of Solid State Optoelectronics Information Technology, Institute of Semiconductors, Chinese Academy of Sciences, Beijing, 100083, China; College of Materials Science and Opto-Electronic Technology, University…
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Tang, J., Jiang, Y., Shen, C., & Feng, C. (2026). Learning-assisted transient-response analysis of nitride high-electron-mobility transistor aptasensors for rapid carcinoembryonic antigen detection. Biosensors and Bioelectronics, 312, 119045. https://doi.org/10.1016/j.bios.2026.119045
Vancouver
Tang J, Jiang Y, Shen C, Feng C. Learning-assisted transient-response analysis of nitride high-electron-mobility transistor aptasensors for rapid carcinoembryonic antigen detection. Biosensors and Bioelectronics. 2026;312:119045. doi:10.1016/j.bios.2026.119045
BibTeX
@article{Tang2026,
author = {Tang, Jian and Jiang, Yunhui and Shen, Chao and Feng, Chun},
title = {Learning-assisted transient-response analysis of nitride high-electron-mobility transistor aptasensors for rapid carcinoembryonic antigen detection},
journal = {Biosensors and Bioelectronics},
year = {2026},
volume = {312},
pages = {119045},
doi = {10.1016/j.bios.2026.119045}
}
EUVIMED