EUVIMEDEUVIMED entdecken
Crossref

Laser-written high-entropy metal–oxy patch for non-enzymatic lactate–pH sweat sensing

Liang Fan, Jianru Wang, Yuxiang Xin, Zhuolei Zhang

Biosensors and Bioelectronics · 2026-11 · 312 · 119028

DOI: 10.1016/j.bios.2026.119028 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2026-11. Verfasst von Liang Fan und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Chemistry and Chemical Engineering, Hubei Key Laboratory of Bioinorganic Chemistry and Materia Medica, Hubei Engineering Research Center fo…. Hauptthemen laut MEDLINE: Sweat, Biosensing Techniques, Lactic Acid. Die Arbeit nennt 57 Literaturangaben. Gefördert von: Guangdong Basic and Applied Basic Research Foundation, China Postdoctoral Science Foundation, Postdoctoral Science Foundation of Hubei Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Wearable sweat analytics demands sensing interfaces that remain catalytically active in biofluids yet are manufacturable in flexible formats. Here we report a one-step CO2-laser writing strategy that converts chitosan-multimetal precursor on polyimide into a porous N-doped graphene (NG) network uniformly anchored with high-entropy multimetal (oxy)nanoparticles (HEMO). The laser process yields a high-entropy (oxy)surface where metallic ensemble sites coexist with oxygenated motifs (M-O/M-OH), generating mixed-valence catalytic centers electronically coupled to the conductive graphene. Leveraging this architecture, the flexible electrode enables lactate-pH co-sensing under neutral conditions. Non-enzymatic lactate detection proceeds via adsorption-assisted electrocatalytic oxidation on multimetal ensemble sites, where the mixed-valence (oxy)surface accelerates interfacial charge transfer and turnover, delivering a linear range of 0.05-20 mM with a detection limit of 8.83 μM. Concurrently, potentiometric pH sensing arises from reversible proton-coupled conversion between -OH and -O-∗ on oxygenated surface groups, producing a linear open-circuit potential (OCP)-pH relationship. Finally, integrating the laser-written electrodes into a skin-conformal patch with microfluidics and wireless electronics enables real-time exercise monitoring, tracking sweat lactate dynamics with pH shifts and agreeing well with standard reference assays. Collectively, this work establishes a scalable, laser-enabled route to high-entropy metal-oxy electrocatalytic interfaces for pH-assisted lactate quantification and multiplexed wearable sweat sensing.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SweatBiosensing TechniquesLactic AcidHumansHydrogen-Ion ConcentrationGraphiteLasersChitosanElectrodesWearable Electronic DevicesElectrochemical TechniquesLimit of DetectionMetal Nanoparticles

Stichwörter der Autor:innen

Enzyme-free lactate sensingHEMO/NGLaser writingSweat analysisWearable biosensorpH monitoring

Substanzen

Lactic AcidGraphiteChitosan

Autor:innen und Institutionen

  • School of Chemistry and Chemical Engineering, Hubei Key Laboratory of Bioinorganic Chemistry and Materia Medica, Hubei Engineering Research Center for Biomaterials and Medical Protective Materials, Key Laboratory of Mat…

Förderung

  • Guangdong Basic and Applied Basic Research Foundation
  • China Postdoctoral Science Foundation
  • Postdoctoral Science Foundation of Hubei Province
  • National Natural Science Foundation of China

Zitieren

APA

Fan, L., Wang, J., Xin, Y., & Zhang, Z. (2026). Laser-written high-entropy metal–oxy patch for non-enzymatic lactate–pH sweat sensing. Biosensors and Bioelectronics, 312, 119028. https://doi.org/10.1016/j.bios.2026.119028

Vancouver

Fan L, Wang J, Xin Y, Zhang Z. Laser-written high-entropy metal–oxy patch for non-enzymatic lactate–pH sweat sensing. Biosensors and Bioelectronics. 2026;312:119028. doi:10.1016/j.bios.2026.119028

BibTeX
@article{Fan2026,
  author = {Fan, Liang and Wang, Jianru and Xin, Yuxiang and Zhang, Zhuolei},
  title = {Laser-written high-entropy metal–oxy patch for non-enzymatic lactate–pH sweat sensing},
  journal = {Biosensors and Bioelectronics},
  year = {2026},
  volume = {312},
  pages = {119028},
  doi = {10.1016/j.bios.2026.119028}
}
Kostenlos starten →