Laser-written high-entropy metal–oxy patch for non-enzymatic lactate–pH sweat sensing
Biosensors and Bioelectronics · 2026-11 · 312 · 119028
DOI: 10.1016/j.bios.2026.119028 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2026-11. Verfasst von Liang Fan und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Chemistry and Chemical Engineering, Hubei Key Laboratory of Bioinorganic Chemistry and Materia Medica, Hubei Engineering Research Center fo…. Hauptthemen laut MEDLINE: Sweat, Biosensing Techniques, Lactic Acid. Die Arbeit nennt 57 Literaturangaben. Gefördert von: Guangdong Basic and Applied Basic Research Foundation, China Postdoctoral Science Foundation, Postdoctoral Science Foundation of Hubei Province.
Abstract (Originalsprache)
Wearable sweat analytics demands sensing interfaces that remain catalytically active in biofluids yet are manufacturable in flexible formats. Here we report a one-step CO2-laser writing strategy that converts chitosan-multimetal precursor on polyimide into a porous N-doped graphene (NG) network uniformly anchored with high-entropy multimetal (oxy)nanoparticles (HEMO). The laser process yields a high-entropy (oxy)surface where metallic ensemble sites coexist with oxygenated motifs (M-O/M-OH), generating mixed-valence catalytic centers electronically coupled to the conductive graphene. Leveraging this architecture, the flexible electrode enables lactate-pH co-sensing under neutral conditions. Non-enzymatic lactate detection proceeds via adsorption-assisted electrocatalytic oxidation on multimetal ensemble sites, where the mixed-valence (oxy)surface accelerates interfacial charge transfer and turnover, delivering a linear range of 0.05-20 mM with a detection limit of 8.83 μM. Concurrently, potentiometric pH sensing arises from reversible proton-coupled conversion between -OH and -O-∗ on oxygenated surface groups, producing a linear open-circuit potential (OCP)-pH relationship. Finally, integrating the laser-written electrodes into a skin-conformal patch with microfluidics and wireless electronics enables real-time exercise monitoring, tracking sweat lactate dynamics with pH shifts and agreeing well with standard reference assays. Collectively, this work establishes a scalable, laser-enabled route to high-entropy metal-oxy electrocatalytic interfaces for pH-assisted lactate quantification and multiplexed wearable sweat sensing.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Chemistry and Chemical Engineering, Hubei Key Laboratory of Bioinorganic Chemistry and Materia Medica, Hubei Engineering Research Center for Biomaterials and Medical Protective Materials, Key Laboratory of Mat…
Förderung
- Guangdong Basic and Applied Basic Research Foundation
- China Postdoctoral Science Foundation
- Postdoctoral Science Foundation of Hubei Province
- National Natural Science Foundation of China
Zitieren
APA
Fan, L., Wang, J., Xin, Y., & Zhang, Z. (2026). Laser-written high-entropy metal–oxy patch for non-enzymatic lactate–pH sweat sensing. Biosensors and Bioelectronics, 312, 119028. https://doi.org/10.1016/j.bios.2026.119028
Vancouver
Fan L, Wang J, Xin Y, Zhang Z. Laser-written high-entropy metal–oxy patch for non-enzymatic lactate–pH sweat sensing. Biosensors and Bioelectronics. 2026;312:119028. doi:10.1016/j.bios.2026.119028
BibTeX
@article{Fan2026,
author = {Fan, Liang and Wang, Jianru and Xin, Yuxiang and Zhang, Zhuolei},
title = {Laser-written high-entropy metal–oxy patch for non-enzymatic lactate–pH sweat sensing},
journal = {Biosensors and Bioelectronics},
year = {2026},
volume = {312},
pages = {119028},
doi = {10.1016/j.bios.2026.119028}
}
EUVIMED