A smartphone-based, calibration-free Nafion-modified SPCE electrochemical sensor for clinical validation of 6-thioguanine in erythrocyte lysate and serum
Biosensors and Bioelectronics · 2026-11 · 312 · 119014
DOI: 10.1016/j.bios.2026.119014 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2026-11. Verfasst von Mei-Juan Wu und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pharmacy, The First Affiliated Hospital, Fujian Medical University, Fuzhou, 350005, China; Department of Pharmacy, National Regional Me…. Hauptthemen laut MEDLINE: Thioguanine, Biosensing Techniques, Smartphone, Electrochemical Techniques. Die Arbeit nennt 27 Literaturangaben. Gefördert von: Fujian Provincial Natural Science Foundation.
Abstract (Originalsprache)
The immunosuppressive prodrugs azathioprine and 6-mercaptopurine necessitate therapeutic drug monitoring of their active metabolite, 6-thioguanine (6-TG), due to their narrow therapeutic window and substantial risk of severe adverse effects. Conventional chromatographic techniques are accurate but impractical for point-of-care (POC) applications. Conversely, existing electrochemical sensors, despite their widespread use, suffer from an over-reliance on nanomaterial modifications to enhance analytical performance and face persistent challenges associated with calibration. This work resolves a long-standing knowledge gap by providing the first experimental validation of the 6-TG redox mechanism on a Nafion-modified screen-printed carbon electrode (SPCE). Through dithiothreitol intervention and electrochemical kinetic analysis, we confirm that 6-TG oxidation proceeds via a disulfide bond-mediated, four-electron, four-proton multi-step pathway. Critically, elucidation of this mechanism reveals a consistent kinetic framework, which directly inspires a universal-slope (US) calibration-free strategy wherein the calibration slope becomes a stable parameter, obviating frequent recalibration for POC applications. Leveraging this mechanistic insight, we constructed a smartphone-assisted electrochemical sensor on the same Nafion/SPCE platform for on-site detection of 6-TG in erythrocyte lysate and serum. The sensor exhibits a linear response from 0.1 to 15 μM in erythrocyte lysate, effectively covering the clinically relevant therapeutic window, alongside excellent selectivity and reproducibility. Clinical validation using 50 patient samples demonstrates strong agreement with high-performance liquid chromatography results, and the US method yields outcomes statistically equivalent to those obtained via the standard addition approach. By resolving the redox mechanism and translating this insight into a calibration-free POC sensor, this work offers a clinically deployable solution for personalized thiopurine therapy.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Pharmacy, The First Affiliated Hospital, Fujian Medical University, Fuzhou, 350005, China; Department of Pharmacy, National Regional Medical Center, Binhai Campus of the First Affiliated Hospital, Fujian M…
Förderung
- Fujian Provincial Natural Science Foundation
Zitieren
APA
Wu, M. J., Chen, J., Lu, J. H., Lin, Y. L., Lin, J. M., Guo, Y. J., Huang, P. F., & Liu, M. M. (2026). A smartphone-based, calibration-free Nafion-modified SPCE electrochemical sensor for clinical validation of 6-thioguanine in erythrocyte lysate and serum. Biosensors and Bioelectronics, 312, 119014. https://doi.org/10.1016/j.bios.2026.119014
Vancouver
Wu MJ, Chen J, Lu JH, Lin YL, Lin JM, Guo YJ, et al. A smartphone-based, calibration-free Nafion-modified SPCE electrochemical sensor for clinical validation of 6-thioguanine in erythrocyte lysate and serum. Biosensors and Bioelectronics. 2026;312:119014. doi:10.1016/j.bios.2026.119014
BibTeX
@article{Wu2026,
author = {Wu, Mei-Juan and Chen, Jing and Lu, Jia-Hui and Lin, Yi-Lan and Lin, Jia-Ming and Guo, Yan-Jin and Huang, Pin-Fang and Liu, Meng-Meng},
title = {A smartphone-based, calibration-free Nafion-modified SPCE electrochemical sensor for clinical validation of 6-thioguanine in erythrocyte lysate and serum},
journal = {Biosensors and Bioelectronics},
year = {2026},
volume = {312},
pages = {119014},
doi = {10.1016/j.bios.2026.119014}
}
EUVIMED