A heart-on-a-chip simultaneously monitoring contractility and troponin secretion under dynamic mechanical stimulation
Biosensors and Bioelectronics · 2026-11 · 312 · 119002
DOI: 10.1016/j.bios.2026.119002 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2026-11. Verfasst von Wenhong Zhang und 7 weiteren Autor:innen. Beteiligte Einrichtung: College of Mechanical Engineering, Donghua University, Shanghai, 201620, China; School of Mechanical Engineering, Qilu University of Technology (Shan…. Hauptthemen laut MEDLINE: Myocytes, Cardiac, Biosensing Techniques, Troponin I, Myocardial Contraction. Die Arbeit nennt 34 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Shandong Province Natural Science Foundation, Department of Science and Technology of Shandong Province.
Abstract (Originalsprache)
Mechanical stimulation can remodel the physiological mechanical microenvironment of cardiomyocytes and influence their maturation and injury progression. However, the dynamic process by which cardiomyocytes transition from adaptive maturation to injury remains unclear, because conventional endpoint assays cannot continuously track cellular states. Here, we developed a heart-on-a-chip platform that reconstructs physiological strain and fluidic microenvironments. The chip integrates traction force microscopy (TFM) and a cardiac troponin I (cTnI) biosensor, enabling synchronous monitoring of cardiomyocyte contractility and injury-associated phenotypes. Under physiological cyclic stretch (20% strain), the platform induced a mature cardiomyocyte phenotype, with the gap junction protein CX43 and cytoskeletal protein F-actin increasing by 1.22- and 2.03-fold, respectively. Through 14 days of dynamic mechano-chemical monitoring, we identified 25% strain as a critical turning point in cardiomyocyte mechanical responses. Below this threshold (5%-20%), mechanical stimulation promoted cellular maturation and enhanced contractile stress, whereas above this threshold (30%), it induced an injury-associated phenotype. This heart-on-a-chip provides a controllable and quantitative in vitro platform for optimizing mechanical stimulation windows, evaluating cardiomyocyte injury, and screening cardioprotective therapeutics.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- College of Mechanical Engineering, Donghua University, Shanghai, 201620, China; School of Mechanical Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan, 250353, China; Shandong Institute of…
- The Key Laboratory of Mechanism Theory and Equipment Design of Ministry of Education, School of Mechanical Engineering, Tianjin University, Tianjin, 300072, China.
- School of Mechanical Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan, 250353, China; Shandong Institute of Mechanical Design and Research, Jinan, 250353, China.
- Department of Radiation Oncology, Shandong Cancer Hospital and Institute, Shandong First Medical University, China.
- School of Mechanical Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan, 250353, China; Shandong Institute of Mechanical Design and Research, Jinan, 250353, China. Electronic address: xch@q…
- School of Mechanical Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan, 250353, China; Shandong Institute of Mechanical Design and Research, Jinan, 250353, China. Electronic address: liwan…
Förderung
- National Natural Science Foundation of China
- Shandong Province Natural Science Foundation
- Department of Science and Technology of Shandong Province
- Jinan Science and Technology Bureau
- Qilu University of Technology
Zitieren
APA
Zhang, W., Wang, Y., Yu, J., Wang, K., Xing, L., Xu, C., Wang, L., & Wang, J. (2026). A heart-on-a-chip simultaneously monitoring contractility and troponin secretion under dynamic mechanical stimulation. Biosensors and Bioelectronics, 312, 119002. https://doi.org/10.1016/j.bios.2026.119002
Vancouver
Zhang W, Wang Y, Yu J, Wang K, Xing L, Xu C, et al. A heart-on-a-chip simultaneously monitoring contractility and troponin secretion under dynamic mechanical stimulation. Biosensors and Bioelectronics. 2026;312:119002. doi:10.1016/j.bios.2026.119002
BibTeX
@article{Zhang2026,
author = {Zhang, Wenhong and Wang, Yushen and Yu, Jinlin and Wang, Ke and Xing, Ligang and Xu, Chonghai and Wang, Li and Wang, Jing},
title = {A heart-on-a-chip simultaneously monitoring contractility and troponin secretion under dynamic mechanical stimulation},
journal = {Biosensors and Bioelectronics},
year = {2026},
volume = {312},
pages = {119002},
doi = {10.1016/j.bios.2026.119002}
}
EUVIMED