A programmable multi-stage microfluidic platform with micro-dam prefiltration and micro-nano hierarchical filter for synergetic capture of CTCs and SERS-based phenotype analysis
Biosensors and Bioelectronics · 2026-11 · 311 · 118962
DOI: 10.1016/j.bios.2026.118962 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2026-11. Verfasst von Yiyuan Liu und 10 weiteren Autor:innen. Beteiligte Einrichtung: School of Instrument Science and Opto-electronic Engineering, Hefei University of Technology, Hefei, 230009, China; State Key Laboratory of Chemical …. Hauptthemen laut MEDLINE: Neoplastic Cells, Circulating, Prostatic Neoplasms, Cell Separation, Lab-On-A-Chip Devices. Die Arbeit nennt 48 Literaturangaben. Gefördert von: Taishan Scholar Foundation of Shandong Province, National Natural Science Foundation of China, Hainan Medical University.
Abstract (Originalsprache)
Prostate cancer, a disease with high incidence among elderly men, is one of the most prevalent malignant tumors in the male urogenital system. In contrast to other cancers, prostate cancer typically has a lower mortality rate relative to its incidence. Consequently, differentiating between progressive and non-progressive prostate cancer proves instrumental for early detection and accurate staging of the disease. PC3 and LNCaP cell lines are representative of distinct prostate cancer subtypes and present as circulating tumor cells (CTCs) at various stages of prostate cancer. LNCaP cells exhibit epithelial characteristics, whereas PC3 cells display mesenchymal traits and are more prone to metastasis. As CTCs serve as important liquid biopsy markers, this study aims to define the characteristics of their heterogeneous surface proteins, providing a potential tool for precise staging and prognostic evaluation in prostate cancer diagnosis and treatment. We developed a programmable multi-stage microfluidic chip integrated with a 7 μm thick photoresist filter and microchannels equipped with multiple functional units. In the prefiltration structure of this chip, a micro-dam with micropillar arrays was utilized to separate blood cells from CTCs based on size differences. Subsequently, prefiltered CTCs, which were conjugated with surface enhanced Raman scattering (SERS) nanoprobes, were captured on the micro-nano hierarchical filter through a synergetic capture strategy involving size exclusion, surface protein recognition, and topographical interaction, and then detected by SERS. Our results showed that the microfluidic chip exhibited a remarkable capture efficiency of about 91.2% for CTCs. Notably, by employing dual Raman reporter molecules, we could easily distinguish two subtypes of prostate cancer CTCs using the chip, enabling both efficient capture and phenotype analysis of CTCs.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Instrument Science and Opto-electronic Engineering, Hefei University of Technology, Hefei, 230009, China; State Key Laboratory of Chemical Safety, College of Control Science and Engineering, China University o…
- School of Instrument Science and Opto-electronic Engineering, Hefei University of Technology, Hefei, 230009, China.
- State Key Laboratory of Chemical Safety, College of Control Science and Engineering, China University of Petroleum (East China), Qingdao, 266580, China.
- Department of Hepatobiliary and Pancreatic Surgery, The Affiliated Hospital of Qingdao University, Qingdao, 266003, China.
- Engineering Research Center of Tropical Medicine Innovation and Transformation, Ministry of Education, College of Pharmacy, Hainan Medical University, Haikou, 571199, China. Electronic address: chengziyi@hainmc.edu.cn.
- State Key Laboratory of Chemical Safety, College of Control Science and Engineering, China University of Petroleum (East China), Qingdao, 266580, China. Electronic address: liandongyu@upc.edu.cn.
Förderung
- Taishan Scholar Foundation of Shandong Province
- National Natural Science Foundation of China
- Hainan Medical University
Zitieren
APA
Liu, Y., Xia, H., Gao, R., Ding, H., Liu, H., Zhan, C., Cong, H., Wang, Y., Feng, Y., Cheng, Z., & Yu, L. (2026). A programmable multi-stage microfluidic platform with micro-dam prefiltration and micro-nano hierarchical filter for synergetic capture of CTCs and SERS-based phenotype analysis. Biosensors and Bioelectronics, 311, 118962. https://doi.org/10.1016/j.bios.2026.118962
Vancouver
Liu Y, Xia H, Gao R, Ding H, Liu H, Zhan C, et al. A programmable multi-stage microfluidic platform with micro-dam prefiltration and micro-nano hierarchical filter for synergetic capture of CTCs and SERS-based phenotype analysis. Biosensors and Bioelectronics. 2026;311:118962. doi:10.1016/j.bios.2026.118962
BibTeX
@article{Liu2026,
author = {Liu, Yiyuan and Xia, Haojie and Gao, Rongke and Ding, Hao and Liu, Hancheng and Zhan, Changbiao and Cong, Haojie and Wang, Yeru and Feng, Yujie and Cheng, Ziyi and Yu, Liandong},
title = {A programmable multi-stage microfluidic platform with micro-dam prefiltration and micro-nano hierarchical filter for synergetic capture of CTCs and SERS-based phenotype analysis},
journal = {Biosensors and Bioelectronics},
year = {2026},
volume = {311},
pages = {118962},
doi = {10.1016/j.bios.2026.118962}
}
EUVIMED