EUVIMEDEUVIMED entdecken
Crossref

Autonomous positive-feedback DNA walker cascade for ultrasensitive detection of DNA repair glycosylases

Zhiqiang Chen, Li Wang, Zhixuan Yu, Erkang Wang, Xiaona Fang, Shufeng Liu

Biosensors and Bioelectronics · 2026-11 · 311 · 118959

DOI: 10.1016/j.bios.2026.118959 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2026-11. Verfasst von Zhiqiang Chen und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Chemistry, Northeast Normal University, Changchun, Jilin, 130024, PR China. Hauptthemen laut MEDLINE: Biosensing Techniques, Uracil-DNA Glycosidase, DNA Glycosylases. Die Arbeit nennt 49 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Shandong Province Natural Science Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Currently, DNA walker-based biosensors used for bioanalysis often suffer from limited amplification efficiency due to irreversible walker consumption and a restricted walking distance. Herein, we report an autonomous positive-feedback DNA walker biosensor for the ultrasensitive electrochemical detection of uracil-DNA glycosylase (UDG) and human alkyladenine DNA glycosylase (hAAG). The platform employs a single bifunctional hairpin probe that integrates target recognition and signal transduction. Through the synergistic action of terminal deoxynucleotidyl transferase (TdT) and exonuclease III (Exo III), a positive-feedback "cleavage-extension-recutting" loop is established, enabling continuous walker regeneration and signal amplification. Benefiting from this autonomous positive-feedback mechanism, the proposed biosensor achieves detection limits of 6.8 × 10-7 U/mL for UDG and 1.5 × 10-6 U/mL for hAAG, representing a reduction of over two orders of magnitude compared with conventional feed-forward DNA walker systems. The sensor exhibits excellent selectivity toward the target glycosylases over structurally similar enzymes and potential interferents, and shows recoveries ranging from 97.8% to 105.4% in serum spike-recovery tests. Furthermore, the platform successfully discriminates cancer cells from normal cells and differentiates serum samples from breast cancer patients and healthy individuals. These results demonstrate that the proposed autonomous positive-feedback DNA walker strategy holds great promise as a versatile and highly sensitive platform for DNA repair enzyme analysis and disease-related biomarker detection.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesUracil-DNA GlycosidaseDNA GlycosylasesHumansDNAElectrochemical TechniquesLimit of DetectionDNA RepairExodeoxyribonucleases

Stichwörter der Autor:innen

Cascade enzymesElectrochemical biosensorHuman alkyladenine DNA glycosylase (hAAG)Positive-feedbackSignal amplificationUracil-DNA glycosylase (UDG)

Substanzen

Uracil-DNA GlycosidaseDNA Glycosylases3-methyladenine-DNA glycosylaseDNAexodeoxyribonuclease IIIExodeoxyribonucleases

Autor:innen und Institutionen

  • School of Chemistry, Northeast Normal University, Changchun, Jilin, 130024, PR China.
  • College of Chemistry and Chemical Engineering, Yantai University, Yantai, Shandong, 264005, PR China.
  • State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, Jilin, 130022, PR China.
  • School of Chemistry, Northeast Normal University, Changchun, Jilin, 130024, PR China. Electronic address: fangxn482@nenu.edu.cn.
  • College of Chemistry and Chemical Engineering, Yantai University, Yantai, Shandong, 264005, PR China. Electronic address: sliu@ytu.edu.cn.

Förderung

  • National Natural Science Foundation of China
  • Shandong Province Natural Science Foundation

Zitieren

APA

Chen, Z., Wang, L., Yu, Z., Wang, E., Fang, X., & Liu, S. (2026). Autonomous positive-feedback DNA walker cascade for ultrasensitive detection of DNA repair glycosylases. Biosensors and Bioelectronics, 311, 118959. https://doi.org/10.1016/j.bios.2026.118959

Vancouver

Chen Z, Wang L, Yu Z, Wang E, Fang X, Liu S. Autonomous positive-feedback DNA walker cascade for ultrasensitive detection of DNA repair glycosylases. Biosensors and Bioelectronics. 2026;311:118959. doi:10.1016/j.bios.2026.118959

BibTeX
@article{Chen2026,
  author = {Chen, Zhiqiang and Wang, Li and Yu, Zhixuan and Wang, Erkang and Fang, Xiaona and Liu, Shufeng},
  title = {Autonomous positive-feedback DNA walker cascade for ultrasensitive detection of DNA repair glycosylases},
  journal = {Biosensors and Bioelectronics},
  year = {2026},
  volume = {311},
  pages = {118959},
  doi = {10.1016/j.bios.2026.118959}
}
Kostenlos starten →