Development of a gut-on-a-chip platform to monitor dynamic GLP-1 secretion from primary intestinal tissue

Weikun Huang, Jiangbo Zhao, Chunjie Xiang, Cong Xie, Heike Ebendorff-Heidepriem, Craig Priest, Robert E Steinert, Michael Horowitz, Richard L Young, Christopher K Rayner, Tongzhi Wu

Biosensors and Bioelectronics · 2026

DOI: 10.1016/j.bios.2026.118921 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2026. Verfasst von Weikun Huang und 10 weiteren Autor:innen. Beteiligte Einrichtung: Centre of Research in Translating Nutritional Sciences to Good Health, School of Medicine, College of Health, Adelaide University, Adelaide, SA, 5000…. Hauptthemen laut MEDLINE: Glucagon-Like Peptide 1, Lab-On-A-Chip Devices, Biosensing Techniques, Intestinal Mucosa. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Hospital Research Foundation, Australian Diabetes Society, National Health and Medical Research Council.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Secreted by enteroendocrine L-cells along the intestinal epithelium, glucagon-like peptide-1 (GLP-1) is a key regulator of glucose and energy homeostasis in health, obesity and type 2 diabetes. Understanding the stimuli and mechanisms governing GLP-1 secretion is fundamental to the development of novel therapies for metabolic disorders. Mechanistic studies have, hitherto, relied largely on well-based static incubation of immortalised cell lines or primary intestinal tissues, approaches that have limited physiological relevance and lack the capacity to monitor dynamic hormone release under biomimetic conditions. This study aimed to develop a microfluidic 'gut-on-a-chip' (GOC) platform to enable assessment of dynamic GLP-1 secretion from primary mouse intestinal tissue in a biomimetic environment. We initially characterised regional GLP-1 secretion capacity along the mouse small intestine to inform device design. A polymethyl methacrylate microchip was then micromachined to accommodate a segment of intestinal tissue and support parallel luminal and serosal perfusion via peristaltic microfluidic pumps. In proof-of-concept experiments, physiological GLP-1 secretagogues (taurocholic acid and glucose) were subsequently delivered to the luminal or serosal surface of duodenal and colonic tissue under continuous or intermittent perfusion. The GOC platform demonstrated superiority over static incubation for studying GLP-1 secretion in primary intestinal tissue, capturing dynamic serosal concentration changes over 2 h while better preserving tissue viability and morphology. This novel system provides a powerful tool to elucidate the mechanisms underlying gut hormone release and to screen candidate GLP-1 secretagogues for potential therapeutic development.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Glucagon-Like Peptide 1Lab-On-A-Chip DevicesBiosensing TechniquesIntestinal MucosaAnimalsMiceEquipment DesignMicrophysiological SystemsMice, Inbred C57BLEnteroendocrine CellsGlucoseHumans

Stichwörter der Autor:innen

Gastrointestinal functionGlucagon-like peptide-1Gut-on-a-chipMicrofluidicsType 2 diabetes

Substanzen

Glucagon-Like Peptide 1Glucose

Autor:innen und Institutionen

  • Centre of Research in Translating Nutritional Sciences to Good Health, School of Medicine, College of Health, Adelaide University, Adelaide, SA, 5000, Australia; Institute for Photonics and Advanced Sensing, School of P…
  • Institute for Photonics and Advanced Sensing, School of Physics, Chemistry and Earth Sciences, Adelaide University, Adelaide, SA, 5000, Australia; School of Engineering, University of Hull, Hull, HU6 7RX, UK.
  • Centre of Research in Translating Nutritional Sciences to Good Health, School of Medicine, College of Health, Adelaide University, Adelaide, SA, 5000, Australia.
  • Institute for Photonics and Advanced Sensing, School of Physics, Chemistry and Earth Sciences, Adelaide University, Adelaide, SA, 5000, Australia.
  • Future Industries Institute, Adelaide University, Mawson Lakes, SA, 5095, Australia; School of Electrical and Mechanical Engineering, Adelaide University, Mawson Lakes, SA, 5095, Australia.
  • Centre of Research in Translating Nutritional Sciences to Good Health, School of Medicine, College of Health, Adelaide University, Adelaide, SA, 5000, Australia; Lifelong Health, South Australian Health & Medical Resear…

Förderung

  • Hospital Research Foundation
  • Australian Diabetes Society
  • National Health and Medical Research Council
  • University of Adelaide
  • Engineering and Physical Sciences Research Council

Zitieren

APA

Huang, W., Zhao, J., Xiang, C., Xie, C., Ebendorff-Heidepriem, H., Priest, C., Steinert, R. E., Horowitz, M., Young, R. L., Rayner, C. K., & Wu, T. (2026). Development of a gut-on-a-chip platform to monitor dynamic GLP-1 secretion from primary intestinal tissue. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2026.118921

Vancouver

Huang W, Zhao J, Xiang C, Xie C, Ebendorff-Heidepriem H, Priest C, et al. Development of a gut-on-a-chip platform to monitor dynamic GLP-1 secretion from primary intestinal tissue. Biosensors and Bioelectronics. 2026. doi:10.1016/j.bios.2026.118921

BibTeX
@article{Huang2026,
  author = {Huang, Weikun and Zhao, Jiangbo and Xiang, Chunjie and Xie, Cong and Ebendorff-Heidepriem, Heike and Priest, Craig and Steinert, Robert E and Horowitz, Michael and Young, Richard L and Rayner, Christopher K and Wu, Tongzhi},
  title = {Development of a gut-on-a-chip platform to monitor dynamic GLP-1 secretion from primary intestinal tissue},
  journal = {Biosensors and Bioelectronics},
  year = {2026},
  doi = {10.1016/j.bios.2026.118921}
}
Kostenlos starten →