Kurz gefasst

Übersichtsarbeit in der Zeitschrift Biosensors and Bioelectronics, 2026-11. Verfasst von Tsung-Hsien Chen und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Internal Medicine, Ditmanson Medical Foundation Chia-Yi Christian Hospital, Chiayi, 60002, Taiwan. Electronic address: cych13794@gmail.…. Hauptthemen laut MEDLINE: Biosensing Techniques, Electrochemical Techniques, Transition Elements, Molybdenum. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 164 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Chiayi Christian Hospital, Kaohsiung Armed Forces General Hospital, National Science and Technology Council.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Electrochemical biosensors enable rapid, low-cost, and portable clinical diagnostics. While graphene has demonstrated ultrasensitive detection, its clinical translation is constrained by reproducibility issues, unstable surface chemistry, and complex fabrication processes. Transition metal dichalcogenides (TMDs) have emerged as promising next-generation materials due to their tunable electronic structures, abundant catalytic active sites, and intrinsic suitability for biofunctionalization, enabling enhanced analytical sensitivity. Despite these advances, their clinical deployment remains limited by material instability, interfacial resistance, signal interference, and insufficient validation in real biological matrices. This review applies a five-axis evaluation framework-analytical performance, operational stability, manufacturability, biointerface compatibility, and system readiness-to systematically assess TMD-based electrochemical biosensors, with a particular focus on MoS2-dominated platforms. We critically examine material properties, device engineering, and key translational gaps, particularly in matrix validation and scalable manufacturing. Furthermore, we propose a gated technology readiness roadmap aligned with regulatory standards to accelerate clinical translation and facilitate the adoption of TMD-based biosensing technologies.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesElectrochemical TechniquesTransition ElementsMolybdenumDisulfidesHumansEquipment DesignGraphite

Stichwörter der Autor:innen

Biosensor validationClinical translationManufacturabilityOperational stabilityPoint-of-care diagnosticsTechnology readiness level

Substanzen

Transition ElementsMolybdenumDisulfidesGraphite

Autor:innen und Institutionen

  • Department of Internal Medicine, Ditmanson Medical Foundation Chia-Yi Christian Hospital, Chiayi, 60002, Taiwan. Electronic address: cych13794@gmail.com.
  • Division of Gastroenterology and Hepatology, Department of Internal Medicine, Ditmanson Medical Foundation Chia-Yi Christian Hospital, Chiayi, 60002, Taiwan. Electronic address: yunxinkoh2@yahoo.com.tw.
  • Department of Mechanical Engineering, National Chung Cheng University, 168, University Rd., Min Hsiung, Chia Yi, 62102, Taiwan; Department of Computer Science Engineering, School of Engineering and Technology, Sanjivani…
  • Department of Mechanical Engineering, National Chung Cheng University, 168, University Rd., Min Hsiung, Chia Yi, 62102, Taiwan; Department of Integrated Bachelor of Technology, School of Engineering and Technology, Sanj…
  • Higher Institute of Medical Technologies of Tunis, University of Tunis El Manar, Campus Universitaire Farhat Hached, B.P. n° 94, Rommana 1068 Tunis, Tunisia. Electronic address: thabetelyes@gmail.com.
  • Department of Mechanical Engineering, National Chung Cheng University, 168, University Rd., Min Hsiung, Chia Yi, 62102, Taiwan. Electronic address: wow60659@gmail.com.

Förderung

  • Chiayi Christian Hospital
  • Kaohsiung Armed Forces General Hospital
  • National Science and Technology Council

Zitieren

APA

Chen, T. H., Koh, K. Y., Mukundan, A., Karmakar, R., Thabet, E., Liu, Y. Y., Chou, C. K., Hsieh, S. C., & Wang, H. C. (2026). From surface to signal: Clinical pathways for transition metal dichalcogenide-based electrochemical biosensors. Biosensors and Bioelectronics, 311, 118913. https://doi.org/10.1016/j.bios.2026.118913

Vancouver

Chen TH, Koh KY, Mukundan A, Karmakar R, Thabet E, Liu YY, et al. From surface to signal: Clinical pathways for transition metal dichalcogenide-based electrochemical biosensors. Biosensors and Bioelectronics. 2026;311:118913. doi:10.1016/j.bios.2026.118913

BibTeX
@article{Chen2026,
  author = {Chen, Tsung-Hsien and Koh, Kok-Yean and Mukundan, Arvind and Karmakar, Riya and Thabet, Elyes and Liu, Yu-You and Chou, Chu-Kuang and Hsieh, Shang-Chin and Wang, Hsiang-Chen},
  title = {From surface to signal: Clinical pathways for transition metal dichalcogenide-based electrochemical biosensors},
  journal = {Biosensors and Bioelectronics},
  year = {2026},
  volume = {311},
  pages = {118913},
  doi = {10.1016/j.bios.2026.118913}
}
Kostenlos starten →