A widely used CRP aptamer does not bind CRP, revealing a general route to surface-driven pseudoaffinity in biosensors
Biosensors and Bioelectronics · 2026-10 · 310 · 118875
DOI: 10.1016/j.bios.2026.118875 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2026-10. Verfasst von Quan Duc Le und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, York University, 4700 Keele Street, Toronto, Ontario, M3J 1P3, Canada; Centre for Research on Biomolecular Interactions, Yor…. Hauptthemen laut MEDLINE: Aptamers, Nucleotide, C-Reactive Protein, Surface Plasmon Resonance, Biosensing Techniques. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Natural Sciences and Engineering Research Council of Canada.
Abstract (Originalsprache)
Aptamer sequences are often reused in biosensors and diagnostics without independent confirmation of binding activity, even though rigorous validation requires quantitative solution-phase testing by orthogonal methods. Here, we re-examined a DNA sequence reported in 2010 to bind C-reactive protein (CRP) with a Kd of 3.5 nM by surface plasmon resonance (SPR) and subsequently adopted in many CRP aptasensor studies. We tested this sequence by two orthogonal solution-phase methods and by SPR. In solution-phase assays, we found no detectable binding of the reported aptamer to native CRP. In SPR, we found that CRP binds strongly to streptavidin-containing sensor surfaces even in the absence of immobilized DNA, whereas the reported sequence produced no measurable ligand-specific SPR response under lower-background capture conditions. Thus, the originally reported affinity is best explained by surface-driven pseudoaffinity rather than true aptamer-CRP recognition. More broadly, this case does not merely add another example of aptamer nonbinding, but reveals a general route by which nonbinding aptamers can acquire apparent affinity through surface-driven pseudoaffinity and then be propagated through the biosensor literature as validated molecular recognition reagents. This study underscores the need for orthogonal solution-phase validation before aptamers are reused in biosensor development and related analytical applications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Chemistry, York University, 4700 Keele Street, Toronto, Ontario, M3J 1P3, Canada; Centre for Research on Biomolecular Interactions, York University, 4700 Keele Street, Toronto, Ontario, M3J 1P3, Canada. El…
- Illumina, Inc., 2945 Wilderness Pl, Boulder, CO, 80301, USA. Electronic address: nclark1@illumina.com.
- Illumina, Inc., 2945 Wilderness Pl, Boulder, CO, 80301, USA. Electronic address: dseghetti@illumina.com.
- Xenolis Pte. Ltd., 85 Science Park Drive, #02-08 the Cavendish, Singapore, Republic of Singapore. Electronic address: ken.ichiro@xenolis.com.
- Xenolis Pte. Ltd., 85 Science Park Drive, #02-08 the Cavendish, Singapore, Republic of Singapore. Electronic address: michiko.kimoto@xenolis.com.
- Xenolis Pte. Ltd., 85 Science Park Drive, #02-08 the Cavendish, Singapore, Republic of Singapore. Electronic address: ichiro.hirao@xenolis.com.
Förderung
- Natural Sciences and Engineering Research Council of Canada
Zitieren
APA
Le, Q. D., Le, A. T. H., Wang, T. Y., Krylova, S. M., Clark, N. A., Seghetti-Hebble, D., Matsunaga, K. I., Kimoto, M., Hirao, I., & Krylov, S. N. (2026). A widely used CRP aptamer does not bind CRP, revealing a general route to surface-driven pseudoaffinity in biosensors. Biosensors and Bioelectronics, 310, 118875. https://doi.org/10.1016/j.bios.2026.118875
Vancouver
Le QD, Le ATH, Wang TY, Krylova SM, Clark NA, Seghetti-Hebble D, et al. A widely used CRP aptamer does not bind CRP, revealing a general route to surface-driven pseudoaffinity in biosensors. Biosensors and Bioelectronics. 2026;310:118875. doi:10.1016/j.bios.2026.118875
BibTeX
@article{Le2026,
author = {Le, Quan Duc and Le, An Thi Hoai and Wang, Tong Ye and Krylova, Svetlana M and Clark, Noah A and Seghetti-Hebble, David and Matsunaga, Ken-Ichiro and Kimoto, Michiko and Hirao, Ichiro and Krylov, Sergey N},
title = {A widely used CRP aptamer does not bind CRP, revealing a general route to surface-driven pseudoaffinity in biosensors},
journal = {Biosensors and Bioelectronics},
year = {2026},
volume = {310},
pages = {118875},
doi = {10.1016/j.bios.2026.118875}
}
EUVIMED