EUVIMEDEUVIMED entdecken
Crossref

Rational design of a genetically encoded fluorescent biosensor for real-time and bidirectional detection of μ-opioid receptor signaling

Ren Ren, Xiao Wang, Shiyun Tang, Jing Chen, Fan Yang, Shucheng Liu, Qihua Chen, Peng Xu, Xiaoyi Chen, Fang Yan, Bin Di

Biosensors and Bioelectronics · 2026-10 · 309 · 118813

DOI: 10.1016/j.bios.2026.118813 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2026-10. Verfasst von Ren Ren und 10 weiteren Autor:innen. Beteiligte Einrichtung: Office of China National Narcotics Control Commission, China Pharmaceutical University Joint Laboratory on Key Technologies of Narcotics Control, Chi…. Hauptthemen laut MEDLINE: Receptors, Opioid, mu, Biosensing Techniques. Die Arbeit nennt 32 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The μ-opioid receptor (MOR) is a key therapeutic target for pain management. However, robust tools for real-time bidirectional monitoring of MOR activation remain limited. Here, we report GEgMOR, a genetically encoded fluorescent biosensor developed via a rational design strategy combining artificial intelligence (AlphaFold3) with genetic engineering. This strategy drastically reduced the number of required mutant constructs from thousands to merely 239, markedly enhancing the efficiency and precision of biosensor development. GEgMOR exhibits outstanding performance in live-cell assays, with a maximum fluorescence response (ΔF/F0 = 472.8%) 8.6-fold higher than the current state-of-the-art MOR sensor, nanomolar affinity (EC50 = 39.67 nM), rapid kinetics (τon ≈ 1.7 s, τoff ≈ 4.9 s) and high opioid specificity, and excellent photostability under both one-photon and two-photon excitation. Further validation in SH-SY5Y and PC12 neuronal cell models confirmed that the core functional properties of GEgMOR are well maintained in a neuronal cellular context. Notably, GEgMOR enables the first real-time, continuous, and bidirectional monitoring of MOR conformational changes upon agonist activation and antagonist inhibition in a single system. This overcomes the limitations of discontinuous, indirect readouts in conventional stepwise assays. Beyond serving as a powerful dynamic MOR imaging tool, this biosensor establishes a scalable cell-based platform for MOR ligand profiling and drug candidate screening. Our work not only provides a powerful imaging and functional analysis tool for MOR research but also establishes a generalizable strategy to accelerate G protein-coupled receptor (GPCR) biosensor development and advance drug discovery.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Receptors, Opioid, muBiosensing TechniquesHumansAnimalsSignal TransductionRatsFluorescent Chemosensor CompoundsGenetic EngineeringPC12 CellsNeurons

Stichwörter der Autor:innen

Artificial intelligenceBidirectional monitoringGenetically encoded biosensorMu-opioid receptorRational design

Substanzen

Receptors, Opioid, muFluorescent Chemosensor Compounds

Autor:innen und Institutionen

  • Office of China National Narcotics Control Commission, China Pharmaceutical University Joint Laboratory on Key Technologies of Narcotics Control, China Pharmaceutical University, Nanjing, 210009, China.
  • Office of China National Narcotics Control Commission, China Pharmaceutical University Joint Laboratory on Key Technologies of Narcotics Control, China Pharmaceutical University, Nanjing, 210009, China; Key Laboratory o…
  • Office of China National Narcotics Control Commission, China Pharmaceutical University Joint Laboratory on Key Technologies of Narcotics Control, China Pharmaceutical University, Nanjing, 210009, China. Electronic addre…
  • Office of China National Narcotics Control Commission, China Pharmaceutical University Joint Laboratory on Key Technologies of Narcotics Control, China Pharmaceutical University, Nanjing, 210009, China; Jiangsu Key Labo…

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Ren, R., Wang, X., Tang, S., Chen, J., Yang, F., Liu, S., Chen, Q., Xu, P., Chen, X., Yan, F., & Di, B. (2026). Rational design of a genetically encoded fluorescent biosensor for real-time and bidirectional detection of μ-opioid receptor signaling. Biosensors and Bioelectronics, 309, 118813. https://doi.org/10.1016/j.bios.2026.118813

Vancouver

Ren R, Wang X, Tang S, Chen J, Yang F, Liu S, et al. Rational design of a genetically encoded fluorescent biosensor for real-time and bidirectional detection of μ-opioid receptor signaling. Biosensors and Bioelectronics. 2026;309:118813. doi:10.1016/j.bios.2026.118813

BibTeX
@article{Ren2026,
  author = {Ren, Ren and Wang, Xiao and Tang, Shiyun and Chen, Jing and Yang, Fan and Liu, Shucheng and Chen, Qihua and Xu, Peng and Chen, Xiaoyi and Yan, Fang and Di, Bin},
  title = {Rational design of a genetically encoded fluorescent biosensor for real-time and bidirectional detection of μ-opioid receptor signaling},
  journal = {Biosensors and Bioelectronics},
  year = {2026},
  volume = {309},
  pages = {118813},
  doi = {10.1016/j.bios.2026.118813}
}
Kostenlos starten →