EUVIMEDEUVIMED entdecken
Evaluationsstudie

Ultrasensitive, robust, and selective detection of hepatitis B surface antigen enabled by vertical organic electrochemical transistor

Saima Aftab, Miao Xie, Jinhao Zhou, Yuhua Cheng, Dan Zhao, Wei Huang

Biosensors and Bioelectronics · 2026

DOI: 10.1016/j.bios.2026.118787 ↗

Kurz gefasst

Evaluationsstudie in der Zeitschrift Biosensors and Bioelectronics, 2026. Verfasst von Saima Aftab und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Automation Engineering, University of Electronic Science and Technology of China, Chengdu, 610054, China. Hauptthemen laut MEDLINE: Hepatitis B Surface Antigens, Biosensing Techniques, Hepatitis B virus, Hepatitis B. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 62 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Fundamental Research Funds for the Central Universities, Natural Science Foundation of Sichuan Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Early detection of hepatitis B virus (HBV) is essential for effective diagnosis and disease management. Hepatitis B surface antigen (HBsAg) is a key biomarker widely used for HBV screening. In this study, we report a vertical organic electrochemical transistor (vOECT)-based biosensor for label-free detection of HBsAg. The device employs a gold gate electrode functionalized with monoclonal HBV antibodies via carbodiimide coupling, providing covalent binding sites for the selective capture of HBsAg. Surface modification and immobilization processes are confirmed by cyclic voltammetry and electrochemical impedance spectroscopy. The biosensor showed a wide linear detection range upon HBsAg binding from 100 pg/mL to 5000 ng/mL with a low detection limit of 42.7 fg/mL. Reproducibility tests showed relative standard deviation (RSD) values of 2.40% and 3.03% for 5.0 ng/mL and 5 μg/mL HBsAg, respectively, indicating high consistency across independently fabricated devices. The biosensor also exhibited strong selectivity against common biological interferents, including bilirubin, recombinant human serum albumin, carcinoembryonic antigen, creatinine, glucose and haemoglobin. Furthermore, stability studies show that more than 98% of the original response is retained after two weeks. These results highlight the potential of the vOECT platform as a sensitive, reliable and compact biosensing strategy for point-of-care HBV diagnostics.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Hepatitis B Surface AntigensBiosensing TechniquesHepatitis B virusHepatitis BElectrochemical TechniquesHumansTransistors, ElectronicLimit of DetectionEquipment DesignAntibodies, ImmobilizedGoldReproducibility of Results

Stichwörter der Autor:innen

Antibody functionalized gateBiosensorHepatitis B surface antigen detectionVertical organic electrochemical transistor

Substanzen

Hepatitis B Surface AntigensAntibodies, ImmobilizedGold

Autor:innen und Institutionen

  • School of Automation Engineering, University of Electronic Science and Technology of China, Chengdu, 610054, China.
  • School of Automation Engineering, University of Electronic Science and Technology of China, Chengdu, 610054, China. Electronic address: whuang@uestc.edu.cn.

Förderung

  • National Natural Science Foundation of China
  • Fundamental Research Funds for the Central Universities
  • Natural Science Foundation of Sichuan Province
  • National Key Research and Development Program of China Stem Cell and Translational Research
  • National Key Research and Development Program of China
  • Chengdu Science and Technology Bureau

Zitieren

APA

Aftab, S., Xie, M., Zhou, J., Cheng, Y., Zhao, D., & Huang, W. (2026). Ultrasensitive, robust, and selective detection of hepatitis B surface antigen enabled by vertical organic electrochemical transistor. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2026.118787

Vancouver

Aftab S, Xie M, Zhou J, Cheng Y, Zhao D, Huang W. Ultrasensitive, robust, and selective detection of hepatitis B surface antigen enabled by vertical organic electrochemical transistor. Biosensors and Bioelectronics. 2026. doi:10.1016/j.bios.2026.118787

BibTeX
@article{Aftab2026,
  author = {Aftab, Saima and Xie, Miao and Zhou, Jinhao and Cheng, Yuhua and Zhao, Dan and Huang, Wei},
  title = {Ultrasensitive, robust, and selective detection of hepatitis B surface antigen enabled by vertical organic electrochemical transistor},
  journal = {Biosensors and Bioelectronics},
  year = {2026},
  doi = {10.1016/j.bios.2026.118787}
}
Kostenlos starten →