Evaluation of the accuracy of wrist skin temperature measured using an infrared sensor for prediction ovulation date
Biosensors and Bioelectronics · 2026
DOI: 10.1016/j.bios.2026.118755 ↗Kurz gefasst
Evaluationsstudie in der Zeitschrift Biosensors and Bioelectronics, 2026. Verfasst von Sung Eun Kim und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Obstetrics and Gynecology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, 06351, South Korea; Department of…. Hauptthemen laut MEDLINE: Biosensing Techniques, Skin Temperature, Ovulation, Ovulation Prediction. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 21 Literaturangaben. Gefördert von: Samsung.
Abstract (Originalsprache)
Technological advancements have made it possible to measure vital signs through wearable devices. This study evaluated the accuracy of wrist skin temperature (WST) measured by a continuous monitoring biosensor in the Galaxy Watch 5 for predicting ovulation dates. We recruited 106 women to measure WST during sleep, oral temperature upon waking, and perform ovulation tests around expected ovulation dates. Ovulation was confirmed via progesterone blood test. We analyzed 225 cycles (85 women) in the full analysis set (FAS), and 156 cycles (52 women) in the per-protocol (PP) set. WST predicted ovulation dates within 2 days in 64.0% (FAS) and 64.1% (PP) of cycles, and within 3 days in 77.8% (FAS) and 78.9% (PP) of cycles. Next menstrual cycle prediction accuracy was 68.2% (FAS) and 69.9% (PP) within 2 days, and 77.8% (FAS) and 84.1% (PP) within 3 days. WST and oral temperature showed moderate correlation (FAS: r = 0.423; PP: r = 0.448). While predicting ovulation within 2 days wasn't statistically significant, prediction within 3 days showed significant results. In conclusion, WST measurement using a continuous monitoring biosensor during sleep may be helpful in predicting ovulation date and next menstruation dates, offering another useful application for wearable devices in reproductive health monitoring.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Obstetrics and Gynecology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, 06351, South Korea; Department of Digital Health, SAIHST, Sungkyunkwan University, Seoul, 06355, South…
- Academic Clinical Research Organization Team, Clinical Research Institute, Research Institute for Future Medicine, Samsung Medical Center, Seoul, 06351, South Korea. Electronic address: youngwoong1.kim@samsung.com.
- Biomedical Statistics Center, Data Science Research Institute, Research Institute for Future Medicine, Samsung Medical Center, Seoul, 06351, South Korea. Electronic address: brknow@naver.com.
Förderung
- Samsung
Zitieren
APA
Kim, S. E., Kim, Y., & Park, B. (2026). Evaluation of the accuracy of wrist skin temperature measured using an infrared sensor for prediction ovulation date. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2026.118755
Vancouver
Kim SE, Kim Y, Park B. Evaluation of the accuracy of wrist skin temperature measured using an infrared sensor for prediction ovulation date. Biosensors and Bioelectronics. 2026. doi:10.1016/j.bios.2026.118755
BibTeX
@article{Kim2026,
author = {Kim, Sung Eun and Kim, Youngwoong and Park, Boram},
title = {Evaluation of the accuracy of wrist skin temperature measured using an infrared sensor for prediction ovulation date},
journal = {Biosensors and Bioelectronics},
year = {2026},
doi = {10.1016/j.bios.2026.118755}
}
EUVIMED