EUVIMEDEUVIMED entdecken
Crossref

Accurate diagnosis of triple-negative breast cancer enables temperature-compensation all optical microfibre gratings system

Xin Liu, Qiao Xu, Yunlong Wang, Chao Wang, Wuchen Liang, Lei Huang, Liang Lu, Jialiang Lv, Jian Gao, Benli Yu, Hongtao Li

Biosensors and Bioelectronics · 2026-08 · 306 · 118706

DOI: 10.1016/j.bios.2026.118706 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2026-08. Verfasst von Xin Liu und 10 weiteren Autor:innen. Beteiligte Einrichtung: School of Physics and Optoelectronic Engineering, State Key Laboratory of Opto-Electronic Information Acquisition and Protection Technology, Informat…. Hauptthemen laut MEDLINE: Triple Negative Breast Neoplasms, Biosensing Techniques. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 52 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Wu Jieping Medical Foundation, University Natural Science Research Project of Anhui Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Accurate clinical diagnosis of triple-negative breast cancer (TNBC) usually needed tedious, time consuming, high-cost tissue section analyzation procedures by using conventional clinical medical approaches. Thus, it is an urgent to develop low-cost, rapid, high-sensitivity TNBC diagnostic approaches. Herein, we have proposed a temperature-compensation short-period microfiber long-period grating (MFLPG) sensor coated with Au nanostars (Au NS)-Nb2CTX MXene coupled with localized surface plasmon resonance (LSPR) effect for the high-sensitivity tracking tumor-derived exosomal programmed cell death ligand-1 (PD-L1) in collected clinical human samples. For sensing exosomes particles in pure phosphate buffered saline (PBS) solution, the sensor device could exhibit an ultra-high detection sensitivity of 0.852 nm/log10 (particles/mL), and an ultra-low limit-of-detection (LOD) of 12.9 particles/mL within the exosomes concentration ranging from 101 particles/mL to 108 particles/mL. More significantly, the MFLPG sensor could differentiate breast cancer patients from healthy controls, and it could also differentiate TNBC patients from some other non-TNBC patients' samples. Therefore, this work could pave a new method for rapid, high-sensitivity and accurate diagnosis of TNBC in clinical samples.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Triple Negative Breast NeoplasmsBiosensing TechniquesHumansFemaleGoldExosomesSurface Plasmon ResonanceTemperatureLimit of DetectionEquipment DesignMetal Nanoparticles

Stichwörter der Autor:innen

Exosomal PD-L1LSPRMFLPGRapid and high-sensitivity diagnosisTNBCTemperature compensation

Substanzen

Gold

Autor:innen und Institutionen

  • School of Physics and Optoelectronic Engineering, State Key Laboratory of Opto-Electronic Information Acquisition and Protection Technology, Information Materials and Intelligent Sensing Laboratory of Anhui Province, Ke…
  • Department of General Surgery, The First Affiliated Hospital of University of Science and Technology of China, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, 230036, China.
  • Department of General Surgery, The First Affiliated Hospital of University of Science and Technology of China, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, 230036, China.…

Förderung

  • National Natural Science Foundation of China
  • Wu Jieping Medical Foundation
  • University Natural Science Research Project of Anhui Province
  • Institute of Energy, Hefei Comprehensive National Science Center
  • Anhui Provincial Natural Science Foundation

Zitieren

APA

Liu, X., Xu, Q., Wang, Y., Wang, C., Liang, W., Huang, L., Lu, L., Lv, J., Gao, J., Yu, B., & Li, H. (2026). Accurate diagnosis of triple-negative breast cancer enables temperature-compensation all optical microfibre gratings system. Biosensors and Bioelectronics, 306, 118706. https://doi.org/10.1016/j.bios.2026.118706

Vancouver

Liu X, Xu Q, Wang Y, Wang C, Liang W, Huang L, et al. Accurate diagnosis of triple-negative breast cancer enables temperature-compensation all optical microfibre gratings system. Biosensors and Bioelectronics. 2026;306:118706. doi:10.1016/j.bios.2026.118706

BibTeX
@article{Liu2026,
  author = {Liu, Xin and Xu, Qiao and Wang, Yunlong and Wang, Chao and Liang, Wuchen and Huang, Lei and Lu, Liang and Lv, Jialiang and Gao, Jian and Yu, Benli and Li, Hongtao},
  title = {Accurate diagnosis of triple-negative breast cancer enables temperature-compensation all optical microfibre gratings system},
  journal = {Biosensors and Bioelectronics},
  year = {2026},
  volume = {306},
  pages = {118706},
  doi = {10.1016/j.bios.2026.118706}
}
Kostenlos starten →