EUVIMEDEUVIMED entdecken
Crossref

Fluctuation-resilient ratiometric SERS enabled by programmable aptamer disassembly for pump-free microfluidic AKI detection

Jin Qian, Zehang Tan, Yucan Zhang, Yibao Huang, Songzhe He, Guixin Shi, Juli Hong, Anhui Wang, Linlu Zhao, Ziyi Cheng

Biosensors and Bioelectronics · 2026

DOI: 10.1016/j.bios.2026.118684 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2026. Verfasst von Jin Qian und 9 weiteren Autor:innen. Beteiligte Einrichtung: Engineering Research Center of Tropical Medicine Innovation and Transformation, Ministry of Education, College of Pharmacy, Key Laboratory of Emergen…. Hauptthemen laut MEDLINE: Lipocalin-2, Acute Kidney Injury, Aptamers, Nucleotide, Biosensing Techniques. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 40 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Hainan Province, Major Science and Technology Project of Hainan Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Acute kidney injury (AKI) requires rapid and reliable biomarker quantification, yet early assessment is hindered by delayed biomarker kinetics and signal fluctuation under decentralized testing conditions. Here, we developed a pump-free microfluidic aptamer-ratiometric surface-enhanced Raman scattering (SERS) platform for simultaneous quantification of neutrophil gelatinase-associated lipocalin (NGAL) and cystatin C (Cys C). The assay uses a Y-shaped aptamer architecture to convert target binding into programmed structural disassembly and controlled release of Au@Ag SERS tags. A substrate-embedded internal standard enables self-calibrated readout through the I1617/I2228 ratio, thereby improving signal robustness against substrate heterogeneity and environmental interference. Integrated into a capillary-driven microfluidic chip, the platform completed dual-biomarker analysis within 15 min. It achieved detection limits of 1 pg/mL for NGAL and 34 pg/mL for Cys C, with excellent linearity (R2 > 0.99). In a cisplatin-induced AKI rat model, both biomarkers increased significantly at 4-6 h after injury, preceding oxidative stress imaging and histopathological changes. Analysis of clinical serum samples showed good agreement with enzyme-linked immunosorbent assay and recovery rates above 99%. These results demonstrate a rapid and reliable strategy for early AKI assessment and quantitative point-of-care biomarker analysis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Lipocalin-2Acute Kidney InjuryAptamers, NucleotideBiosensing TechniquesCystatin CAnimalsSpectrum Analysis, RamanRatsHumansGoldLimit of DetectionBiomarkersSilverLab-On-A-Chip DevicesMaleCisplatinMicrofluidic Analytical TechniquesMetal Nanoparticles

Stichwörter der Autor:innen

Acute kidney injuryAptamerPoint-of-care testingPump-free microfluidicsRatiometric surface-enhanced Raman scattering

Substanzen

Lipocalin-2Aptamers, NucleotideCystatin CGoldBiomarkersSilverCisplatin

Autor:innen und Institutionen

  • Engineering Research Center of Tropical Medicine Innovation and Transformation, Ministry of Education, College of Pharmacy, Key Laboratory of Emergency and Trauma of Ministry of Education, Department of Intensive Care U…

Förderung

  • National Natural Science Foundation of China
  • Natural Science Foundation of Hainan Province
  • Major Science and Technology Project of Hainan Province
  • Hainan Medical University

Zitieren

APA

Qian, J., Tan, Z., Zhang, Y., Huang, Y., He, S., Shi, G., Hong, J., Wang, A., Zhao, L., & Cheng, Z. (2026). Fluctuation-resilient ratiometric SERS enabled by programmable aptamer disassembly for pump-free microfluidic AKI detection. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2026.118684

Vancouver

Qian J, Tan Z, Zhang Y, Huang Y, He S, Shi G, et al. Fluctuation-resilient ratiometric SERS enabled by programmable aptamer disassembly for pump-free microfluidic AKI detection. Biosensors and Bioelectronics. 2026. doi:10.1016/j.bios.2026.118684

BibTeX
@article{Qian2026,
  author = {Qian, Jin and Tan, Zehang and Zhang, Yucan and Huang, Yibao and He, Songzhe and Shi, Guixin and Hong, Juli and Wang, Anhui and Zhao, Linlu and Cheng, Ziyi},
  title = {Fluctuation-resilient ratiometric SERS enabled by programmable aptamer disassembly for pump-free microfluidic AKI detection},
  journal = {Biosensors and Bioelectronics},
  year = {2026},
  doi = {10.1016/j.bios.2026.118684}
}
Kostenlos starten →