Rapid and simultaneous on-site detection of influenza A(H1N1) virus and Mycoplasma pneumoniae nucleic acids using magnetic RPA ratiometric fluorescent lateral flow assay
Biosensors and Bioelectronics · 2026-08 · 306 · 118680
DOI: 10.1016/j.bios.2026.118680 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2026-08. Verfasst von You Nie und 9 weiteren Autor:innen. Beteiligte Einrichtung: Laboratory of Respiratory Diseases, Beijing Pediatric Research Institute, Beijing Children's Hospital, Capital Medical University, Beijing Key Labora…. Hauptthemen laut MEDLINE: Influenza A Virus, H1N1 Subtype, Mycoplasma pneumoniae, Biosensing Techniques, Influenza, Human. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 27 Literaturangaben. Gefördert von: Natural Science Foundation of Beijing Municipality, Ministry of Science and Technology of the People's Republic of China, Beijing Municipal Health Commission.
Abstract (Originalsprache)
Influenza A(H1N1) virus [InfA (H1N1)] and Mycoplasma pneumoniae (MP) are key pediatric respiratory pathogens with overlapping symptoms, necessitating rapid and simultaneous on-site detection of nucleic acids for optimal clinical management. Herein, we developed a finger-actuated and contamination-resistant PEARL chip integrating magnetic bead-based pathogen enrichment and cascade duplex recombinase polymerase amplification (RPA) for a ratiometric fluorescence lateral flow assay (LFA), which allows both visual and quantitative detection of InfA (H1N1) and MP. 3-Aminophenylboronic acid (APBA)-functionalized magnetic beads enabled rapid target enrichment from complex matrices within 3 min, with capture efficiencies up to 97.8%. The ratiometric LFA strips operate based on fluorescence color ratio variation, which arises from the signal overlap of two fluorescent nanomaterials tagged with detection and capture antibodies. With the ratiometric LFA readout, the duplex RPA-facilitated assay yield visual detection limits of 100 copies/mL for InfA (H1N1) and 1000 copies/mL for MP, respectively. Moreover, a custom smartphone-based portable device and its accompanying application are available as an optional approach to enable quantitative analysis within the defined dynamic range. The entire PEARL chip process is completed within 20 min. Across 93 pediatric clinical samples, PEARL demonstrated strong concordance with qPCR, achieving 100% sensitivity for H1N1 and 93.3% sensitivity for MP, with 100% specificity for both pathogens. Overall, the PEARL chip provides a rapid, sensitive, and user-friendly platform for simultaneous detection of pediatric respiratory pathogens, holding great promise for decentralized and point-of-care diagnostic applications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Laboratory of Respiratory Diseases, Beijing Pediatric Research Institute, Beijing Children's Hospital, Capital Medical University, Beijing Key Laboratory of Core Technologies for the Prevention and Treatment of Emerging…
- Department of Toxicology and Sanitary Chemistry, School of Public Health, Capital Medical University, Beijing, 100069, China; Beijing Key Laboratory of Environment and Aging, Beijing, 100069, China.
- Stomatology Department, Jining Medical University, Shandong, 272067, China.
- Department of Toxicology and Sanitary Chemistry, School of Public Health, Capital Medical University, Beijing, 100069, China; Beijing Key Laboratory of Environment and Aging, Beijing, 100069, China. Electronic address:…
Förderung
- Natural Science Foundation of Beijing Municipality
- Ministry of Science and Technology of the People's Republic of China
- Beijing Municipal Health Commission
- Beijing Municipal Science and Technology Commission
- National Science and Technology Major Project
- Beijing Nova Program
Zitieren
APA
Nie, Y., Liu, H., Li, J., Zeng, Z., Wu, Y., Mao, G., Jiang, Y., Cao, Y., Sun, L., & Hao, R. (2026). Rapid and simultaneous on-site detection of influenza A(H1N1) virus and Mycoplasma pneumoniae nucleic acids using magnetic RPA ratiometric fluorescent lateral flow assay. Biosensors and Bioelectronics, 306, 118680. https://doi.org/10.1016/j.bios.2026.118680
Vancouver
Nie Y, Liu H, Li J, Zeng Z, Wu Y, Mao G, et al. Rapid and simultaneous on-site detection of influenza A(H1N1) virus and Mycoplasma pneumoniae nucleic acids using magnetic RPA ratiometric fluorescent lateral flow assay. Biosensors and Bioelectronics. 2026;306:118680. doi:10.1016/j.bios.2026.118680
BibTeX
@article{Nie2026,
author = {Nie, You and Liu, Hao and Li, Jianyong and Zeng, Zhi and Wu, Yi and Mao, Guanyu and Jiang, Yitong and Cao, Yuanyuan and Sun, Lin and Hao, Rongzhang},
title = {Rapid and simultaneous on-site detection of influenza A(H1N1) virus and Mycoplasma pneumoniae nucleic acids using magnetic RPA ratiometric fluorescent lateral flow assay},
journal = {Biosensors and Bioelectronics},
year = {2026},
volume = {306},
pages = {118680},
doi = {10.1016/j.bios.2026.118680}
}
EUVIMED