Microbial fuel cell (MFC)-based biosensor for real-time detection of heavy metals and BTEX contaminants in water
Biosensors and Bioelectronics · 2026
DOI: 10.1016/j.bios.2026.118675 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2026. Verfasst von Jong-Hyun Baik und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Civil, Environmental, and Construction Engineering, University of Central Florida, Orlando, FL, USA. Hauptthemen laut MEDLINE: Biosensing Techniques, Bioelectric Energy Sources, Water Pollutants, Chemical, Benzene Derivatives. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 33 Literaturangaben. Gefördert von: Korea Environment Institute, Korea Environmental Industry and Technology Institute, Ministry of Education, Ethiopia.
Abstract (Originalsprache)
This study evaluates a mixed-culture microbial fuel cell (MFC) as a rapid, real-time biosensor for detecting water toxicity caused by heavy metals and benzene, toluene, ethylbenzene, and xylene (BTEX) compounds. A dual-chamber MFC (200 mL) equipped with carbon fiber electrodes was operated with an electroactive biofilm on the anode, and toxicity responses were quantified using inhibition ratios (IR) derived from voltage suppression following contaminant exposure. The biosensor effectively detected copper (Cu2+) and mercury (Hg2+) over a concentration range of 2-20 mg L-1, exhibiting strong linear relationships (R2 = 0.9928 and R2 = 0.9811, respectively). Mixed-culture biofilms showed a 1.64-fold increase in sensitivity compared to pure cultures and demonstrated stable baseline signals. The biosensor also responded linearly to benzene and xylene (R2 = 0.9876 and R2 = 0.9811) with rapid response times of 1.0-3.5 min. Microbial community analysis indicated increased richness and evenness following MFC operation, supporting biofilm stability during short-term exposure. The developed biosensor is intended for early-warning and process-health monitoring in industrial and wastewater systems, where rapid detection of toxicity spikes is critical. These findings demonstrate the feasibility of MFC-based biosensors as low-cost, in situ tools for integrative toxicity surveillance.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Civil, Environmental, and Construction Engineering, University of Central Florida, Orlando, FL, USA.
- Department of Building, Civil and Environmental Engineering, Concordia University, Montreal, QC, Canada.
- Drinking Water Science and Engineering Division, Office of Water, U.S. Environmental Protection Agency, Cincinnati, OH, USA.
- Department of Biological and Environmental Science, Dongguk University, Goyang, Republic of Korea.
- Department of Civil, Environmental, and Construction Engineering, University of Central Florida, Orlando, FL, USA. Electronic address: WooHyoung.Lee@ucf.edu.
Förderung
- Korea Environment Institute
- Korea Environmental Industry and Technology Institute
- Ministry of Education, Ethiopia
- Ministry of Environment
- U.S. Environmental Protection Agency
Zitieren
APA
Baik, J. H., Hwang, J. H., Ryu, H., Gomez-Alvarez, V., Kim, K. T., & Hyoung Lee, W. (2026). Microbial fuel cell (MFC)-based biosensor for real-time detection of heavy metals and BTEX contaminants in water. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2026.118675
Vancouver
Baik JH, Hwang JH, Ryu H, Gomez-Alvarez V, Kim KT, Hyoung Lee W. Microbial fuel cell (MFC)-based biosensor for real-time detection of heavy metals and BTEX contaminants in water. Biosensors and Bioelectronics. 2026. doi:10.1016/j.bios.2026.118675
BibTeX
@article{Baik2026,
author = {Baik, Jong-Hyun and Hwang, Jae-Hoon and Ryu, Hodon and Gomez-Alvarez, Vicente and Kim, Keug-Tae and Hyoung Lee, Woo},
title = {Microbial fuel cell (MFC)-based biosensor for real-time detection of heavy metals and BTEX contaminants in water},
journal = {Biosensors and Bioelectronics},
year = {2026},
doi = {10.1016/j.bios.2026.118675}
}
EUVIMED