Dual-site PGM-based point-of-care detection of EGFR exon 19 deletion with an endogenous internal control
Biosensors and Bioelectronics · 2026-08 · 305 · 118674
DOI: 10.1016/j.bios.2026.118674 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2026-08. Verfasst von Hyo Won Jeon und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biotechnology, College of Life Sciences & Biotechnology, Korea University, Seoul, 02841, Republic of Korea; User Convenience Technology…. Hauptthemen laut MEDLINE: ErbB Receptors, Biosensing Techniques, Carcinoma, Non-Small-Cell Lung, Lung Neoplasms. Die Arbeit nennt 36 Literaturangaben. Gefördert von: Korea Ministry of Trade Industry and Energy.
Abstract (Originalsprache)
Rapid and reliable detection of EGFR exon 19 deletion (19del) is important for precision treatment of non-small cell lung cancer, yet current genotyping methods remain poorly suited for point-of-care testing (POCT). This limitation is particularly significant in signal-off assays, where reaction failure can be misinterpreted as a true negative result. Here, we present a dual-site personal glucose meter (PGM)-readout platform for minimal-instrumentation analysis of EGFR 19del. In this system, target-dependent flap endonuclease 1 (FEN1) cleavage generates adenosine monophosphate (AMP), which triggers a glucose-consuming kinase cascade and enables direct quantitative readout using a commercial PGM without optical instrumentation or nucleic acid amplification. To improve interpretability, the platform incorporates an endogenous internal control through a dual-site design consisting of a mutation-discriminating detection site and a conserved control site, thereby enabling reliable interpretation of signal-off readouts while confirming sample adequacy. The platform achieved sensitive detection with a limit of detection of approximately 27 pM and discriminated mutation fractions down to ∼0.44% in wild-type/mutant mixtures. Its feasibility was further demonstrated using cell-derived genomic DNA and serum-containing samples. These results indicate that the proposed platform provides an accessible and practical strategy for decentralized EGFR 19del testing.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Biotechnology, College of Life Sciences & Biotechnology, Korea University, Seoul, 02841, Republic of Korea; User Convenience Technology R&D Department, Korea Institute of Industrial Technology (KITECH), An…
- Department of Biologics, Gachon University, Incheon, 21936, Republic of Korea.
- User Convenience Technology R&D Department, Korea Institute of Industrial Technology (KITECH), Ansan, 15588, Republic of Korea; School of Chemical Engineering, Sungkyunkwan University, Suwon, 16419, Republic of Korea.
- Department of Biologics, Gachon University, Incheon, 21936, Republic of Korea. Electronic address: jkahn@gachon.ac.kr.
Förderung
- Korea Ministry of Trade Industry and Energy
Zitieren
APA
Jeon, H. W., Han, H., Yang, J., & Ahn, J. K. (2026). Dual-site PGM-based point-of-care detection of EGFR exon 19 deletion with an endogenous internal control. Biosensors and Bioelectronics, 305, 118674. https://doi.org/10.1016/j.bios.2026.118674
Vancouver
Jeon HW, Han H, Yang J, Ahn JK. Dual-site PGM-based point-of-care detection of EGFR exon 19 deletion with an endogenous internal control. Biosensors and Bioelectronics. 2026;305:118674. doi:10.1016/j.bios.2026.118674
BibTeX
@article{Jeon2026,
author = {Jeon, Hyo Won and Han, Hyogu and Yang, Jieun and Ahn, Jun Ki},
title = {Dual-site PGM-based point-of-care detection of EGFR exon 19 deletion with an endogenous internal control},
journal = {Biosensors and Bioelectronics},
year = {2026},
volume = {305},
pages = {118674},
doi = {10.1016/j.bios.2026.118674}
}
EUVIMED