EUVIMEDEUVIMED entdecken
Evaluationsstudie

Trimetallic mesoporous nanozyme–mediated lateral flow assay enables ultrasensitive visual simultaneous detection of biological and chemical contaminants

Wenlong Bai, Jin Zhang, Lei Ren, Fanglin Liu, Long Zhang, Zhigang Li, Chongwen Wang, Shuai Zheng, Shu Wang

Biosensors and Bioelectronics · 2026-08 · 306 · 118662

DOI: 10.1016/j.bios.2026.118662 ↗

Kurz gefasst

Evaluationsstudie in der Zeitschrift Biosensors and Bioelectronics, 2026-08. Verfasst von Wenlong Bai und 8 weiteren Autor:innen. Beteiligte Einrichtung: Hefei Institute of Physical Science, Chinese Academy of Sciences, Hefei, 230036, PR China; University of Science and Technology of China, Hefei, 2300…. Hauptthemen laut MEDLINE: Escherichia coli O157, Biosensing Techniques. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 35 Literaturangaben. Gefördert von: National Natural Science Foundation of China, China Postdoctoral Science Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The vast molecular-weight range of biological versus chemical contaminants limits the ability of current methods to achieve simultaneous detection of mixed contamination within a single assay. Here, we report a colorimetric dual-mode lateral flow assay (DMLFA) using trimetallic mesoporous nanozyme tags (dPdPt-Ir) that unifies sandwich and competitive formats with an ultrasensitive substrate-catalyzed readout on a single test strip, enabling accurate, simultaneous detection of a representative biological contaminant (bacteria) and a chemical contaminant (clenbuterol, CLE). The dPdPt-Ir enhances DMLFA performance by: (1) supplying abundant catalytic sites via a ternary, mesoporous framework to elevate peroxidase-like activity, sensitivity, and signal dynamic range; (2) increasing antibody loading and target capture through a high-roughness mesoporous surface; and (3) providing structural stability through an all-metallic framework for reliable operation in complex matrices. The proposed DMLFA allows simultaneous quantification of E. coli O157 and CLE within 20 min, with LODs of 35 cells/mL and 7.15 pg/mL. It shows wide linear ranges (E. coli O157: 50-1 × 106 cells/mL; CLE: 0.01-100 ng/mL), 100-fold enhanced visual sensitivity, RSD

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Escherichia coli O157Biosensing TechniquesColorimetryLimit of DetectionPorosityMetal Nanoparticles

Stichwörter der Autor:innen

CLEDual-mode lateral flow assayE. coli O157Mixed contaminationNanozyme

Autor:innen und Institutionen

  • Hefei Institute of Physical Science, Chinese Academy of Sciences, Hefei, 230036, PR China; University of Science and Technology of China, Hefei, 230026, PR China.
  • Department of Pharmacy, Air Force Medical Center, Air Force Medical University, Beijing, 100142, PR China.
  • Hefei Institute of Physical Science, Chinese Academy of Sciences, Hefei, 230036, PR China.
  • Department of Clinical Laboratory Medicine, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou, Guangdong, 510000, PR China. Electronic address: wangch…
  • Hefei Institute of Physical Science, Chinese Academy of Sciences, Hefei, 230036, PR China; Wan Jiang New Industry Technology Development Center, Tongling, 244000, PR China. Electronic address: kapposnn@163.com.
  • Hefei Institute of Physical Science, Chinese Academy of Sciences, Hefei, 230036, PR China. Electronic address: wangshu@aiofm.ac.cn.

Förderung

  • National Natural Science Foundation of China
  • China Postdoctoral Science Foundation

Zitieren

APA

Bai, W., Zhang, J., Ren, L., Liu, F., Zhang, L., Li, Z., Wang, C., Zheng, S., & Wang, S. (2026). Trimetallic mesoporous nanozyme–mediated lateral flow assay enables ultrasensitive visual simultaneous detection of biological and chemical contaminants. Biosensors and Bioelectronics, 306, 118662. https://doi.org/10.1016/j.bios.2026.118662

Vancouver

Bai W, Zhang J, Ren L, Liu F, Zhang L, Li Z, et al. Trimetallic mesoporous nanozyme–mediated lateral flow assay enables ultrasensitive visual simultaneous detection of biological and chemical contaminants. Biosensors and Bioelectronics. 2026;306:118662. doi:10.1016/j.bios.2026.118662

BibTeX
@article{Bai2026,
  author = {Bai, Wenlong and Zhang, Jin and Ren, Lei and Liu, Fanglin and Zhang, Long and Li, Zhigang and Wang, Chongwen and Zheng, Shuai and Wang, Shu},
  title = {Trimetallic mesoporous nanozyme–mediated lateral flow assay enables ultrasensitive visual simultaneous detection of biological and chemical contaminants},
  journal = {Biosensors and Bioelectronics},
  year = {2026},
  volume = {306},
  pages = {118662},
  doi = {10.1016/j.bios.2026.118662}
}